This site is in beta — data may be incomplete and features are still being added.
Back to Bylaws
No. 985

Subdivision and Development Servicing Bylaw No. 985, 2017

Adopted 2017
Download PDF

Plain English Summary

This bylaw governs how land is subdivided and developed in View Royal, BC. It outlines the required infrastructure and services, such as roads, sidewalks, water, sewer, and drainage, that developers must provide. It applies to all land within the Town of View Royal. The bylaw details the application process for development and subdivisions, including preliminary layout reviews. It also specifies minimum standards for highway frontage and grants the Approving Officer the power to make exemptions. The bylaw also outlines the fees and securities required, delegating authority to the Director of Engineering to determine off-site service requirements and enter into related agreements. Additionally, it covers general provisions, enforcement measures for violations, and effective dates. Schedules outline specific design guidelines, construction specifications, and approved product lists.

Legislative Timeline

May 6, 2025

Council Meeting

Subdivision and Development Servicing Bylaw No. 985, 2017, Amendment Bylaw No. 1152, 2025

April 15, 2025

Council Meeting

Subdivision and Development Servicing Bylaw No. 985, 2017, Amendment Bylaw No. 1152, 2025

November 7, 2017

Council Meeting

Subdivision and Development Servicing Bylaw No. 985, 2017 A Bylaw to Require the Provision of Works and Services and to Establish Standards and Regulations in Respect to the Subdivision and Development of Land within the Town of View Royal

October 17, 2017

Council Meeting

Subdivision and Development Servicing Bylaw No. 985, 2017

2017Town of View Royal

Adopted 2017

Official adoption year of Bylaw No. 985

Document Outline

Part 1 TITLE, APPLICABILITY, SEVERABILITY AND REPEAL

1.1 Title

1.2 Applicability

1.3 Severability

1.4 Repeal

Part 2 INTERPRETATION

2.1 Definitions

2.2 Requirements Supplementary

2.3 Amendments or Replacements

2.4 Definitions from Legislation or MMCD

2.5 Designates

2.6 Standards of Measure

2.7 Bylaw Schedules

Part 3 MINIMUM HIGHWAY FRONTAGE

3.1

Part 4 DESIGNATION OF SERVICING OFFICER

4.1

Part 5 APPLICATIONS

Application for Preliminary Layout Assessment:

5.1

5.2

5.3

Subdivision Preliminary Layout Review Letter

5.4

5.5

5.6

5.7

Additional Information

5.8

Referral to Other Agencies

5.9

Part 6 SERVICING REQUIREMENTS FOR SUBDIVISIONS AND DEVELOPMENTS

6.1

6.2

6.3

6.4

6.5

6.6

6.7

6.8 Exemptions

6.9 Highways

6.10 Boulevard and Sidewalks – New and Existing Highways

6.11 Driveways – New and Existing

6.12 Street Lighting

6.13 Power Supply

6.14 Power Services

6.15 Telecommunications Supply

6.16 Telecommunications Services

6.17 Water Distribution

6.18 Fire Hydrant System

6.19 Sanitary Sewage System

6.20 Drainage System

6.21 On-site Stormwater Management System

6.22

6.23

6.24

6.25 Latecomer Charge Interest Rate

Part 7 FEES AND SECURITY

7.1 Fees and Payment of Charges

7.2 Subdivision and Development Fees

7.3 Works and Services Security

7.4 Maintenance Security

7.5 Owner Responsibility and Remedy

PART 8 GENERAL PROVISIONS

8.1 Compliance

8.2 Cost of Services

8.3 Consulting Engineer

8.4 Rights-of-Way and Easements

8.5 Transfer of Ownership

8.6 Record Drawings

PART 9 ENFORCEMENT

9.1

9.2 Violation

9.3 Penalties

PART 10 EFFECTIVE DATE

10.1

SCHEDULE A Level of Service Map (Roads)

SCHEDULE B SUPPLEMENTARY DESIGN GUIDELINES

SCHEDULE C SUPPLEMENTARY CONSTRUCTION SPECIFICATIONS

SCHEDULE D SUPPLEMENTARY DETAIL DRAWINGS

SCHEDULE E Approved Products List

SCHEDULE F SUPPLEMENTARY DRAWING STANDARDS

Full Text

 
 
 
 
 
 
 
 
 
 
 
 
TOWN OF VIEW ROYAL 
SUBDIVISION AND DEVELOPMENT  
SERVICING BYLAW NO. 985, 2017 
Consolidated for Convenience to May 2025 
 
 
 
 
 
 
 
 
 
 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017  
- i -  
Town of View Royal 
Consolidated Version 
 
 
TABLE OF CONTENTS 
 
 
Part 1 TITLE, APPLICABILITY, SEVERABILITY AND REPEAL ................................................................. 1 
Part 2 INTERPRETATION ................................................................................................................... 1 
Part 3 MINIMUM HIGHWAY FRONTAGE.............................................................................................. 7 
Part 4 APPLICATIONS ....................................................................................................................... 8 
Part 5 SERVICING REQUIREMENTS FOR SUBDIVISIONS AND DEVELOPMENTS .................................... 9 
Part 6 FEES AND SECURITY............................................................................................................. 12 
PART 7  GENERAL PROVISIONS ......................................................................................................... 14 
PART 8  ENFORCEMENT .................................................................................................................... 15 
PART 9 EFFECTIVE DATE .................................................................................................................. 16 
 
Schedule A – Level of Service Map (Roads) 
Schedule B – Supplementary Design Guidelines 
Schedule C – Supplementary Construction Specifications 
Schedule D – Supplementary Detail Drawings 
Schedule E – Approved Products List 
 
Schedule F – Drawing Specifications 
 
 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 1 -  
Town of View Royal 
Consolidated Version 
TOWN OF VIEW ROYAL 
BYLAW NO. 985, 2017 
 
 
A BYLAW TO REQUIRE THE PROVISION OF WORKS AND SERVICES AND TO ESTABLISH 
STANDARDS AND REGULATIONS IN RESPECT TO THE SUBDIVISION AND DEVELOPMENT OF 
LAND WITHIN THE TOWN OF VIEW ROYAL 
 
 
The Council of the Town of View Royal, in open meeting, enacts as follows: 
 
PART 1 
TITLE, APPLICABILITY, SEVERABILITY AND REPEAL 
 
1.1 
Title 
This Bylaw may be cited as "Subdivision and Development Servicing Bylaw No. 985, 2017”.  
 
1.2 
Applicability 
 
This Bylaw applies to all lands within the area incorporated as the Town of View Royal. 
 
1.3 
Severability 
 
If any Part, Section, Subsection, Paragraph or phrase of this Bylaw is for any reason held to be 
invalid by the decision of a Court of competent jurisdiction, such decision will not affect the 
validity of the remaining portions of this Bylaw. 
 
1.4 
Repeal 
The following sections of the Town of View Royal Land Use Bylaw, 1990, No. 35, as amended, 
are hereby repealed: 
 
• 
Part 8 – Subdivision and Development 
• 
Schedule 8A – Subdivision Servicing Agreement 
• 
Schedule 8B – Development Servicing Agreement 
• 
Schedule 9 – Developers Agreement Security 
 
PART 2 
INTERPRETATION 
 
2.1 
Definitions 
 
"Application for Development" means the information, documents, agreements, covenants and 
fees required under this Bylaw for a development or subdivision. 
 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 2 -  
Town of View Royal 
Consolidated Version 
"Approval, Final" means the Approving Officer’s affixation of his or her signature to the 
subdivision plan prepared by a currently practicing British Columbia Surveyor pursuant to the 
Land Title Act.  
 
"Approving Officer" means the person appointed as such from time to time by the Council as the 
Approving Officer under the Land Title Act, and includes his or her lawful designate. 
 
"Benefiting Lands" means lands, other than lands that are the subject of the Owner’s Application 
for Development, that are capable of being connected to or serviced by Excess or Extended 
Services. 
 
"Boulevard" means the portion of a highway between the curb lines or the lateral boundary lines 
of a roadway and the adjoining lot or between curbs on median strips or islands, but does not 
include curbs, sidewalks, ditches, or driveways. 
 
"Building Bylaw" means the Town of View Royal Building Bylaw, No. 1111, 2023, as amended or 
replaced from time to time. 
 
"Building Inspector" means the person duly appointed as such from time to time by the Council 
and includes any person designated by the Building Inspector to act on his or her behalf. 
 
“Building Permit” means a permit issued pursuant to the Building Bylaw. 
 
"Certificate of Final Acceptance" means the written confirmation issued by the Director of 
Engineering to the Owner that the Warranty Period for the Works and the Landscaping, 
respectively, has expired, and that all deficiencies of the Works and the Landscaping, 
respectively, upon inspection by the Director of Engineering, have been corrected to the 
satisfaction of the Director of Engineering. 
 
"Certificate of Substantial Performance" means the certificate issued by the Owner’s Consulting 
Engineer for the Works and Landscape Architect for the Landscaping, respectively, indicating that 
Substantial Performance has been achieved. 
 
"Certificate of Total Completion" means following receipt of the Certificate of Substantial 
Performance issued for the Works by the Consulting Engineer and the Landscaping by the 
Landscape Architect, the written confirmation of satisfactory completion of the Works and the 
Landscaping, respectively, issued by the Director of Engineering to the Owner. 
 
“Community Drainage System” means a system of works owned, operated and maintained by the 
Ministry of Transportation or the Town, designed and constructed to control the collection, 
conveyance and disposal of surface and other water. 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 3 -  
Town of View Royal 
Consolidated Version 
 
“Community Sewer System” means a sanitary sewer or a system of sewage disposal works which 
is owned, operated and maintained by the Town. 
 
“Community Water System” means a system of waterworks which includes the water distribution 
and treatment facilities which are owned, operated or maintained by the Capital Regional District.  
 
"Construct" or "Construction" means build, erect, install, repair, alter, add, enlarge, move, locate, 
re-locate, re-construct, upgrade, demolish, remove, excavate, or shore. 
 
"Consulting Engineer" means a professional engineer who is licensed and registered to practice in 
British Columbia under the Engineers and Geoscientists Act, who is responsible for the design, 
construction, supervision and certification of all Works and Services on behalf of the Owner. 
 
“Council” means the Municipal Council of the Town of View Royal. 
 
"Design Drawings" means the drawings identifying the Works and Services requirements of this 
Bylaw, provided by the Owner and submitted to the Town pursuant to an Application for 
Development. 
 
“Develop” or “Development” means any activity that requires a building permit under the 
Building Bylaw. 
 
"Director of Engineering" means the Director of Engineering of the Town, or designate. 
 
“Driveway” means that portion of a property that provides access to Parking or loading spaces 
within the property and is considered to be the extension of the property’s Street access. 
 
“Driveway Crossing” means the improved portion of the Boulevard or Sidewalk specifically 
designated and improved to provide vehicular access to a property, and includes the widest 
extent of the Driveway flare. 
 
“Estimated Cost of Works and Services” means an estimate prepared by the Consulting Engineer 
that itemizes the fair market value or cost of construction of the Work and Services and which 
includes the value of all professional fees for design, approvals, construction period services and 
record drawings. 
 
"Excess or Extended Services" is as defined in the Local Government Act. For convenience the 
current definition is: 
(a) 
a portion of a Highway system that will provide access to land other than the 
land being subdivided or developed, and 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 4 -  
Town of View Royal 
Consolidated Version 
(b) 
a portion of a water, sewage or drainage system that will serve land other than 
the land being subdivided or developed. 
 
"Fees" means those fees payable to the Town in connection with the Subdivision or Development 
of land, as prescribed by the Fees and Charges Bylaw No. 958, 2016, as amended or replaced 
from time to time. 
 
“Frontage” means that length of lot boundary which immediately adjoins a highway, other than a 
lane or walkway. 
 
"Highway" or “Street” includes the width of a public right-of-way including roadway, boulevard, 
lane, walkway, curb and sidewalk open to public use, but does not include a private right-of-way 
on private property. 
  
“Lane” means a highway more than 3 metres but not greater than 8 metres in width, intended to 
provide secondary access to a lot. 
 
“Latecomer Agreement” means a written agreement in the form prescribed by the Town that 
describes the terms and conditions agreed upon between the Town and Owner regarding the 
requirement for Excess or Extended services to be constructed pursuant to Section 507(3) of the 
Local Government Act. 
 
“Latecomer Charge” means a charge imposed on Benefitting Lands as a condition of a Benefitting 
Land connecting to or using the Excess or Extended Services pursuant to Section 508 of the Local 
Government Act.  
 
“Lot” means any parcel, block or other area in which land is held or into which it is subdivided 
whether under the Land Title Act or the Bare Land Strata Regulations under the Strata Property 
Act and includes a water lot, but does not include a phased subdivision boundary. 
 
"Maintenance Period" means the period of time following Total Completion of the Works and 
Services where the Owner continues to maintain the Works and Services for a period of: 
(a) 
three years for required landscaping; and 
(b) 
one year for all other required Works and Services. 
 
“MMCD”  means the Master Municipal Construction Document (latest edition) and the MMCD 
Design Guidelines (latest edition), as amended or replaced including their supplemental updates, 
which forms part of this Bylaw, unless specifically modified by this Bylaw’s Schedules.  
  
“Off-site Works and Services” means Works and Services that are directly attributable to the 
Subdivision or Development and that will be owned and maintained by the Town or the Capital 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 5 -  
Town of View Royal 
Consolidated Version 
Regional District or the Province of British Columbia following issuance of the Certificate of Final  
Acceptance. 
  
"Owner" means the registered owner of a lot or parcel in fee simple, or an agent authorized in 
writing by the owner, and includes: 
a) 
the tenant for life under a registered life estate; 
b) 
the registered holder of the last registered agreement for sale; and 
c) 
the holder or occupier of land held in the manner as referenced the Local 
Government Act, Land Title Act or Strata Property Act. 
 
"Owner/Consulting Engineer Confirmation" means a confirmation letter from the Owner and the 
Consulting Engineer, in the form prescribed by the Town. 
  
“Panhandle Lot” means any lot that has less than 10% of its perimeter adjoining a highway and 
gains access to said highway by means of a narrow strip of land, or access strip, which is an 
integral part of the lot. 
  
"Preliminary Layout Review" means such drawings, plans, information and documents as the 
Approving Officer requires, and in such form as is required by the Approving Officer, to 
determine, on a preliminary basis: 
a) 
whether the proposed Subdivision would be against the public interest or 
otherwise unsuitable for Subdivision; and 
b) 
if not against the public interest or otherwise unsuitable for Subdivision, what the 
Owner must include in the Application for Development. 
 
"Preliminary Layout Review Letter" means a letter from the Approving Officer to the Owner 
advising of the Approving Officer’s response to Preliminary Layout Review information provided 
by the Owner, generally outlining the conditions required to be considered for Final Approval, 
subject to reasonable conditions and provisos. 
 
”Record Drawings" means drawings prepared by and certified by the Consulting Engineer, and 
verified by the Town, that record the location, properties and details of all Works and Services as 
they were built.  The drawings should be stamped to verify the “As-Constructed” drawings.  
“Roadway” means the portion of a highway that is constructed, improved, designed or used for 
vehicular traffic or bicycle traffic or both. 
 
"Roadway Construction Permit" means a permit issued by the Town in connection with an 
application by an Owner to Construct Works and Services on, in or under a Highway or Town 
lands, or to encroach upon a Highway or Town lands in constructing Works and Services on the 
Owner’s lands. 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 6 -  
Town of View Royal 
Consolidated Version 
 
"Security" means cash or a clean, unconditional, irrevocable and automatically renewing letter of 
credit drawn on a chartered bank or credit union, on terms satisfactory to the Town. 
 
"Servicing Agreement" means an agreement between the Owner and the Town made pursuant to 
Section 219 of the Land Title Act, in substantially the form as prescribed and provided by the 
Town. 
 
“Servicing Officer” means the servicing officer pursuant to Section 513.2 of the Local Government 
Act.  
 
“Subdivision” is as defined in the Local Government Act. For convenience the current definition is: 
(a) a subdivision as defined in the Land Title Act, and (b) a subdivision under the Strata Property 
Act;  
 
"Substantial Performance" means the stage of completion of all of the Works and Services when 
the Works and Services are ready to be used for their intended purpose, as certified by the 
Consulting Engineer and verified by the Town. 
 
"Total Completion" means when all Works and Services, including all incomplete, defective or 
deficient Works and Services that were apparent when the Certificate of Substantial Performance 
was issued have been completed or corrected, as certified by the Consulting Engineer and 
verified by the Town. 
 
”Town” means the Town of View Royal. 
 
“Town Specifications” means all the schedules to this bylaw and MMCD. 
 
“Works and Services Agreement” means a written agreement in a form prescribed by the Town 
that describes the terms and conditions agreed upon between the Town and the Owner relative 
to provision of Works and Services associated with a Subdivision or Development. 
 
"Works and Services" includes site grading, Highways, sidewalks, boulevards, boulevard 
crossings, transit bays, street lighting, wiring, water distribution systems, fire hydrants, sewage 
collection and disposal systems, drainage collection and disposal systems, engineering, record 
drawings and such other infrastructure or systems as may be provided within the Town from 
time to time. 
 
"Zoning Bylaw" means Town of View Royal Zoning Bylaw 2014, No. 894, as amended or replaced 
from time to time. 
 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 7 -  
Town of View Royal 
Consolidated Version 
2.2 
Requirements Supplementary 
 
The requirements of this Bylaw are supplementary to the requirements of any other Town bylaw. 
 
2.3 
Amendments or Replacements 
 
A reference to any bylaw, legislation or documents includes any amendments or replacements 
that may be made from time to time. 
 
2.4 
Definitions from Legislation or MMCD 
 
Unless otherwise defined in this Bylaw, any word or expression has the meaning assigned to it in 
the Land Title Act, Local Government Act, Community Charter, Strata Property Act or in the 
MMCD. 
 
2.5 
Designates 
 
Words directing or empowering any officer of the Town to do any act or thing, or otherwise 
referencing the officer by the officer’s official title include that person’s successors in office, the 
officer’s lawful deputy and such person as the Council may by bylaw or resolution designate to 
act in the officer’s place. 
 
2.6 
Standards of Measure 
 
Any equivalent imperial units of measure shown, in parenthesis, after metric units are for 
information purposes only and do not form part of this Bylaw. 
 
2.7 
Bylaw Schedules 
 
The following schedules are attached to and form part of this Bylaw: 
 
• 
Schedule A – Level of Service Map (Roads) 
• 
Schedule B – Supplementary Design Guidelines 
• 
Schedule C – Supplementary Construction Specifications 
• 
Schedule D – Supplementary Detail Drawings 
• 
Schedule E – Approved Products List 
 
• 
Schedule F – Drawing Specifications 
 
PART 3 
MINIMUM HIGHWAY FRONTAGE  
 
3.1 
Council delegates to the Approving Officer the power to exempt a Lot, other than a panhandle 
Lot, from the minimum Frontage requirement under the Local Government Act.  
 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 8 -  
Town of View Royal 
Consolidated Version 
Part 4 
DESIGNATION OF SERVICING OFFICER 
 
4.1 
Pursuant to Section 513.2(4) of the Local Government Act:  
 
a) The Director of Engineering is hereby designated as a Servicing Officer for the Town of View 
Royal; and 
 
b) The Deputy Director of Engineering, Director of Development Services and the Approving 
Officer are classes of persons prescribed in the Local Government Act to be designated as a 
Servicing Officer for the Town of View Royal if the Director of Engineering position is vacant 
or unable to act. 
 
Part 5 
APPLICATIONS 
 
Application for Preliminary Layout Assessment: 
 
5.1 
Prior to the preparation of survey plans and the placing of survey posts or other survey 
monuments upon the land for the purpose of subdivision, an owner may apply to the Approving 
Officer for Preliminary Layout Review Letter. 
 
5.2 
An application described in Section 4.1 of this bylaw shall be made to the Approving Officer, and 
shall be: 
a) signed by the owner of the land that is the subject of the application, or by a person authorized 
in writing by the owner to act as his or her agent for the purpose of making the application; 
b) made on the application form prescribed by the Approving Officer; 
c) accompanied by the information required by the Approving Officer; and 
d) accompanied by the application fee set out in the Fees and Charges Bylaw No. 958  
 
5.3 
The Approving Officer’s issuance of a Preliminary Layout Review Letter must not be construed as 
final approval of the proposed subdivision for land registration purposes.  
 
Subdivision Preliminary Layout Review Letter 
5.4 
In connection with the review of an application for Preliminary Layout Assessment, the Approving 
Officer may issue a Preliminary Layout Review Letter identifying all conditions or requirements that 
are necessary for the Approving Officer’s consideration of final approval of the proposed subdivision.  
 
5.5 
The Approving Officer’s Preliminary Layout Review Letter shall not be construed as final approval of 
a subdivision.  
 
5.6 
If the Approving Officer’s final approval of the proposed subdivision has not been granted within one 
year of the issuance of the Preliminary Layout Review Letter:  
a) 
the Preliminary Layout Review Letter expires; and  

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 9 -  
Town of View Royal 
Consolidated Version 
b) 
if the owner wishes to proceed with the proposed subdivision, a new application for Preliminary 
Layout Assessment must be submitted subject to any change in conditions, bylaws, or policies 
that may have occurred.  
5.7 
Prior to the expiry of the Preliminary Layout Review Letter the owner may apply, in writing, for an 
extension of no more than six (6) months of the Preliminary Layout Review Letter, provided a written 
explanation of the circumstances support the extension and fee for “Statement of Conditions 
Renewal or extension” prescribed in the Fees and Charges Bylaw No. 958, 2016 is paid.  
 
Additional Information  
5.8 
At any time, the Approving Officer may request that an owner provide further information that is 
necessary for the Approving Officer to review and consider a Preliminary Layout Plan.  
 
Referral to Other Agencies  
5.9 
In the event that the Approving Officer or the Town refers the application for Preliminary Layout 
Assessment or any other application for subdivision approval to another public authority whose 
review of that application is required by law, or in the opinion of the Approving Officer is necessary or 
desirable, the owner shall be responsible for direct payment to that public authority of any fee 
charged by the public authority for that referral.“ 
 
PART 6 
SERVICING REQUIREMENTS FOR SUBDIVISIONS AND DEVELOPMENTS 
 
6.1 
Prior to Final Approval or issuance of a Building Permit, the Subdivision or Development must be 
provided with Works and Services within the Subdivision, and in connection with the Subdivision, 
and/or the Lot being developed as prescribed in this Bylaw.  
 
6.2 
Prior to Final Approval or issuance of a Building Permit, the Subdivision or Development must be 
provided with Off-Site Works and Services as determined by the Director of Engineering.  
 
6.3 
The Director of Engineering is hereby delegated the authority to:  
a) 
Determine what Off-Site Works and Services are directly attributable to subdivision or 
development and are accordingly required in any particular case; 
b) 
Determine what Excess or Extended Services are required in connection with a 
Subdivision or Development;  
c) 
Determine whether the cost of those Excess or Extended Services are excessive such 
that the municipality cannot pay for those costs;  
d) 
Identify the Benefiting Lands in relation to Excess or Extended Services;  
e) 
Determine what proportion of the costs associated with the Excess or Extended Services 
is associated with each benefiting property; and 
f) 
Enter into a Works and Services Agreement in a form generally consistent with the 
circumstances and in accordance with good engineering practices, Town policies and this 
Bylaw. 
 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 10 -  
Town of View Royal 
Consolidated Version 
6.4 
The Director is not required to undertake such determinations as listed in Section 5.3, and may 
refer any application that requires Excess or Extended Services to Council.  
 
6.5 
All Off-Site Works and Services must be provided to the Town Specifications. 
 
6.6 
All on-site services required must comply with the BC Building Code, or good engineering 
practices where the code is silent, and must be constructed prior to subdivision. 
 
6.7 
Despite Section 5.1 and Section 5.2, the Owner may obtain Final Approval or a Building Permit prior 
to the provision of Off-Site Works and Services if the Owner has provided Security in accordance 
with this Bylaw, and has entered into a Works and Services Agreement with the Town.  
 
6.8 
Exemptions 
 
Despite Section 5.1 and Section 5.2, the Works and Services requirements of this Bylaw do not 
apply to a Subdivision which only creates:  
a) a Highway dedication;  
b) park land;  
c) a Lot for the installation of public utilities and related structures equipment; or  
d) a consolidation or a lot line adjustment, in which the number of buildable lots is not 
increased. 
6.9 
Highways  
Where any parcel is to be subdivided or developed, all new highways proposed to be dedicated by 
subdivision plan, including widening strips of existing highways, cul-de-sacs, lanes and walkways 
shall be provided, located and constructed and have the dimensions, locations, alignment and 
gradient all in accordance with this Bylaw. 
6.10 
Boulevard and Sidewalks – New and Existing Highways 
a) Where any parcel is to be subdivided or developed and new highways are to be created, 
boulevards and sidewalks shall be provided, located, designed and constructed by the owner in 
accordance with this Bylaw. 
b) Where any parcel is to be subdivided or developed, and there is an existing highway 
immediately adjacent to the parcel, boulevards and sidewalks shall be provided, located, 
designed and constructed by the owner in accordance with this Bylaw. 
6.11 
Driveways – New and Existing 
a) Where any parcel is to be subdivided or developed, the driveway crossings shall be provided, 
located and constructed in accordance with this Bylaw. 
b) The Driveway Crossing surface must be constructed of a hard material, such as concrete or 
asphalt, unless permitted by the director, and must extend a minimum of 1.0m onto the 
property. 
c) Driveway Crossing that is not serving any traffic as a result of the site layout on the property 
must be removed and the portion of the Street reinstated at the Owner’s cost to a condition 
similar to that of the Boulevard in the immediate vicinity.  

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 11 -  
Town of View Royal 
Consolidated Version 
d) An Owner of a Parcel may not access that parcel through an adjoining Parcel’s Driveway 
Crossing unless: 
i) 
the Owner complies with all requirements of this Bylaw with regard to the Driveway 
Crossing; and  
ii) the Owner’s Parcel benefits from a registered easement allowing vehicles to pass through 
the adjoining Parcel to access the Driveway Crossing. 
6.12 
Street Lighting  
Where any parcel is to be subdivided or developed, street light shall be provided, located and 
constructed in accordance with this Bylaw. 
6.13 
Power Supply  
Where any parcel is to be subdivided or developed, and new highways are created, the power 
supply system shall be provided, located and constructed underground.  
6.14 
Power Services  
Where any parcel is to be subdivided or developed, the power services shall be provided, located 
and constructed underground.  
6.15 
Telecommunications Supply  
Where any parcel is to be subdivided or developed, and new highways are created, the 
telecommunication system shall be provided, located and constructed underground.  
6.16 
Telecommunications Services  
Where any parcel is to be subdivided or developed, the telecommunication services shall be 
provided, located and constructed underground. 
6.17 
Water Distribution  
Where any parcel is to be subdivided or developed, such subdivision or development shall be 
connected to Community Water System, which shall be provided, located and constructed in 
accordance with the standards of the Capital Regional District. 
6.18 
Fire Hydrant System  
Where any parcel is subdivided or developed, and a water distribution system must be installed, a 
fire hydrant system shall be provided located in accordance with this Bylaw and constructed in 
accordance with the standards of the Capital Regional District. 
6.19 
Sanitary Sewage System  
Where any parcel is to be subdivided or developed: 
a) 
Such subdivision or development shall be connected to the Community Sewer System, which 
shall be provided, located and constructed in accordance with the standards set out in this 
Bylaw. 
b) 
For on-site and off-site sanitary lateral connections to the Community Sewer System, the 
Director of Engineering has the discretion to waive the requirement for a new lateral if the 
existing lateral:  
 
i) is constructed of a PVC material in accordance with this Bylaw;  
 
ii) is free of defects and deficiencies, including but not limited to excessive damage and root 
intrusions; and  

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 12 -  
Town of View Royal 
Consolidated Version 
 
iii) is in adequate condition and servicing capacity in consideration of good engineering 
practice.  
c) On-site lateral connections must be designed and conform to the BC Building Code and the 
Building Bylaw.  
6.20 
Drainage System  
Where any parcel is proposed to be subdivided or developed, such subdivision or development shall 
be connected to Community Drainage System, which shall be provided, located and constructed in 
accordance with the standards set out in this Bylaw. 
6.21 
On-site Stormwater Management System  
Where any parcel is proposed to be subdivided or developed, such subdivision or development: 
a) Shall have a Stormwater Management Plan, in accordance with the standards set out in the 
Bylaw, prepared by a consulting engineer to address all drainage, entering and exiting the 
existing lots, proposed lots, and Common Property, to maintain post development drainage to 
predevelopment levels provided on-site to the satisfaction of the Director of Engineering; and  
b) Must incorporate water quality treatment provisions into the design, to meet the performance 
targets specified in the Town’s Storm Water Regulation Bylaw No. 902, 2015.  
6.22 
In lieu of Off-site Works and Services being completed, the Town and the Developer may enter into 
a written agreement for cash in lieu paid to the Town in the amount determined by the Director for 
the cost of designing and constructing or altering the Off-site Works and Services if the Director 
determines on the basis of sound civil engineering practice or cost considerations that the Works 
and Services should be constructed or altered at a later time or concurrently with future capital 
construction on the same frontage road.  
 
6.23 
The Director may apply the funds collected under Section 5.22 to capital projects and within the 
term specified in the agreement, and the Owner shall have no further obligation to the Town in 
respect of those Off-site Works and Services. 
 
6.24 
If an agreement cannot be reached, the developer is required to construct the Off-site Works and 
Services as part of the development. 
 
6.25 
Latecomer Charge Interest Rate 
Pursuant to Section 508(4) of the Local Government Act, the annual rate of interest applied to 
latecomer charges with respect to the excess or extended services shall be calculated as a 5 
percent charge on the date of completion of the excess or extended works. 
 
PART 7 
FEES AND SECURITY 
 
7.1 
Fees and Payment of Charges 
 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 13 -  
Town of View Royal 
Consolidated Version 
The Owner must pay all applicable fees and charges prior to Final Approval, issuance of a 
Preliminary Layout Review Letter, issuance of a Road Construction Permit, or issuance of Building 
Permit, as the case may be. 
 
7.2 
Subdivision and Development Fees 
 
(a) 
Pay the Engineering Administration and Inspection fee as prescribed in the Fees and 
Charges Bylaw. 
(b) 
Pay any outside consulting costs incurred by the Town relating to the subdivision and 
servicing of the land. 
 
7.3 
Works and Services Security 
 
a) 
The Owner must pay to the Town a Security in an amount equal to one hundred and 
twenty percent (120%) of the Estimated Cost of Works and Services required for the 
proposed Subdivision or Development to meet the requirements of this Bylaw in order to 
be granted Final approval or issuance of a Building Permit prior to the provision of Works 
and Services.  
 
b) 
The Owner is responsible for the actual cost of the Works and Services regardless of the 
adequacy of the Security deposited with the Town.  
 
c) 
Following Substantial Performance of the Works and Services, the Town will reduce the 
amount of Security to a total of 10% of the Estimated Cost of Works and Services plus 
120% of the remaining deficiencies as determined by the Director of Engineering. 
 
7.4 
Maintenance Security  
 
a) 
Following Total Completion of the Works and Services, the Town will hold Security for the 
maintenance of the Works and Services, in the amount of 10% of the Estimated Cost of 
Works and Services.  
 
b) 
The Security will be held by the Town for the duration of the Maintenance Period as 
provided for in this Bylaw. 
 
7.5 
Owner Responsibility and Remedy 
 
a) 
All Works and Services required to be constructed or provided pursuant to the provisions 
of this Bylaw remain the sole responsibility of the Owner until a Certificate of Final 
Acceptance has been issued by the Town.  
 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 14 -  
Town of View Royal 
Consolidated Version 
b) 
The Owner must maintain the works and repair or replace any defective works during the 
Maintenance Period.  
 
c) 
Should the Owner fail to maintain, repair or replace said works, the Town may undertake 
such maintenance, repairs or replacement using the Security. 
 
PART 8  GENERAL PROVISIONS 
 
8.1 
Compliance 
 
No lot may be Subdivided or Developed, unless the Subdivision or Development conforms to the 
provisions set out in this Bylaw and other bylaws of the Town.  
 
8.2 
Cost of Services 
 
All Works and Services required by this Bylaw must be constructed at the expense of the Owner. 
 
8.3 
Consulting Engineer 
 
a) 
The Owner must, at its expense, retain a Consulting Engineer to design, inspect, test and 
certify all Works and Services.  
 
b) 
The Consulting Engineer is responsible for the design of the respective works and must, 
upon satisfactory completion of the Works and Services, provide the Town with their 
written certification that they were, in fact, designed and constructed in accordance with 
this Bylaw and the submitted Record Drawings.  
 
c) 
Upon request by the Director of Engineering, the Consulting Engineer must supply copies 
of all inspection reports to the Town. 
 
d) 
Any inspection carried out by the Town shall not relieve the Consulting Engineer or 
Owner of any obligations or responsibility in connection with the installation of the works. 
 
8.4 
Rights-of-Way and Easements 
 
a) 
Works and Services constructed and installed under this Bylaw must be located within 
dedicated highways or within statutory rights-of-way granted by the Owner in favour of 
the Town or other agencies having jurisdiction. 
  

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 15 -  
Town of View Royal 
Consolidated Version 
b) 
Where the Owner is required to grant rights-of-way to the Town, the Owner must 
register the rights-of-way in the Land Title Office. The terms of the rights-of-way 
documentation are subject to Approving Officer consent prior to registration. 
 
c) 
Upon registration of the rights-of-way and before release of any maintenance Security 
being held by the Town, the Owner must submit a copy of the registered rights-of-way 
plan and agreement to the Town.  
 
d) 
All costs pertaining to the acquisition, surveying and registration of all rights-of-ways are  
at the expense of the Owner.  
 
8.5 
Transfer of Ownership 
 
Works and Services constructed and installed under this Bylaw become the property of the Town 
or the agency having jurisdiction, subject to no encumbrances, on issuance of the Certificate of 
Final Acceptance. 
  
8.6 
Record Drawings 
 
The Owner must submit Record Drawings following the completion of the Works and Services 
and prior to issuance of a Certificate of Final Acceptance.  
 
If the Owner wishes to receive Final Approval prior to submission of required Record Drawings, 
tests results, service cards, inspection reports, video reports, maintenance and operations 
manuals, and professional certifications, such approval may be granted at the sole discretion of 
the Director of Engineering, subject to a deficiency holdback in an amount set by the Director of 
Engineering pursuant to this Bylaw. 
 
PART 9  ENFORCEMENT 
 
9.1 
The Approving Officer, Director of Engineering, Building Inspector, or designate, are authorized 
to enter at all reasonable times upon the lands for which an Application for Development has 
been made, for the purpose of administering or enforcing this Bylaw. No person may prevent or 
obstruct any such official from the carrying out of these duties under this Bylaw.   
 
9.2 
Violation 
 
a) No person shall contravene this Bylaw or suffer or permit any act or thing to be done in 
contravention of this Bylaw.  
 

 
 
Subdivision and Development Servicing Bylaw No. 985, 2017 
- 16 -  
Town of View Royal 
Consolidated Version 
b) It is an offence for any person to cause, suffer, or permit the development or subdivision of 
land in contravention of this Bylaw or otherwise to contravene or fail to comply with this 
Bylaw. 
 
c) It is an offence for any person to prevent or obstruct, or attempt to prevent or obstruct the 
authorized entry of the Approving Officer or other appointed employee, authorized under this 
Bylaw. 
 
9.3 
Penalties 
 
a) 
Every person who violates a provision of this Bylaw commits an offence and is liable 
upon summary conviction to a penalty of not less than $500.00 and not exceeding ten 
thousand dollars ($10,000) and costs of prosecution.   
 
b) 
Every day of violation constitutes a separate offense. 
 
PART 10 EFFECTIVE DATE 
 
10.1 
This Bylaw comes into force and takes effect upon the final reading and adoption thereof.  
 
 
 
READ A FIRST TIME this 17th DAY OF OCTOBER, 2017. 
 
READ A SECOND TIME this 17th DAY OF OCTOBER, 2017. 
 
READ A THIRD TIME this 17th DAY OF OCTOBER, 2017. 
 
ADOPTED BY COUNCIL, SIGNED BY THE MAYOR AND THE CORPORATE OFFICER AND SEALED WITH 
THE SEAL OF THE TOWN OF VIEW ROYAL THIS 7th DAY OF NOVEMBER, 2017. 
 
 
 
______________________ 
 
 
 
 
______________________ 
MAYOR  
 
 
 
 
 
 
CORPORATE OFFICER 
 
 

SCHEDULE A 
Level of Service Map (Roads) 
 
 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DESIGN GUIDELINES 
NOVEMBER 2017 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 


TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DESIGN GUIDELINES 
CONSOLIDATED TO MAY 2025 
 
SCHEDULE B 
SUPPLEMENTARY DESIGN GUIDELINES 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

GENERAL DESCRIPTION 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DESIGN GUIDELINES 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
 
 
SUPPLEMENTARY DESIGN GUIDELINE GENERAL USE DESCRIPTION 
This schedule contains supplementary design guidelines to be applied in conjunction with the  
Master Municipal Construction Documents, which shall apply to all Works and Services constructed 
within the Town of View Royal. 
 
Supplementary Design Guidelines contained within this Schedule supplement or supersede the Master 
Municipal Construction Document (MMCD). Where the Town of View Royal Supplementary Design 
Guidelines are in conflict with the MMCD, the Town of View Royal Design Guidelines shall take 
precedence. 
Section number and clause numbers in the Town of View Royal Supplementary Design Guidelines 
coincide with the MMCD numbering protocol. 
Table of Contents 
Section 
Description 
Section 1.0 
General Design Considerations 
1.7 
Decommissioning 
 
Section 2.0 
Water Distribution 
 
Section 3.0 
Sanitary Sewers 
 
Section 4.0 
Storm Management 
4.3.2 
Stormwater Design Criteria 
4.3.4 
Climate Change Impact Considerations 
4.7 
Runoff Analysis Method 
4.8 
Rainfall Data 
 
 
Section 5.0 
Roads 
5.3 
Cross-Section Elements 
5.11.1 
Sidewalk 
5.13 
Transit Facilities 
5.14 .3 
Driveway Location and Width 
5.14.4 
Driveway Grades 
5.17.3 
Pavement Alternatives 
 
Section 12.0 
Landscape Requirements 
12.1 
Plans 
12.2 
Boulevard Trees 
12.3 
Tree Retention 
 
Amendment Bylaw No. 1152, 2025 

GENERAL DESIGN 
CONSIDERATIONS 
SECTION 1.0 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DESIGN GUIDELINES 
 
Section 1.0 - General Design Considerations 
Add the following: 
 
1.7 - Decommissioning 
 
A. 
Existing Pipe Utilities 
 
Unless otherwise approved, all abandoned pipes within public rights-of-way shall be removed and 
disposed of off-site as per applicable environmental requirements. Trench backfilling shall be performed 
in accordance with trench backfilling procedures required for new pipe installation. All disturbed 
surfaces shall be restored to equal or better conditions. 
B. 
Existing Sanitary Lift Stations 
 
The preferred method of decommissioning abandoned sanitary lift stations includes total removal of the 
pump tank (wet well) and all associated works within the tank, electrical and instrumentation 
components, and abandoning and permanently sealing off all pipes connecting to the tank. If a concern 
exists that the removal of the below ground tank may cause soil instability and disturbance to the 
existing nearby structures, the tank may be abandoned in place after the following procedure is 
followed: 
 
• 
Thoroughly flush the tank and all connecting pipes, 
• 
Isolate pump tank entirely from all piping, electrical and instrumentation connections by 
disconnecting and removing services and sealing off the pipes with concrete grout or similar 
material, 
• 
Strip the inside area of the tank off of any metallic and non-metallic components, 
• 
Remove tank lid and cut off and remove tank wall to minimum 1m depth below finished surface 
• 
Drill 8 horizontal symmetrical 100mm dia. holes per each metre of height of remaining tank in 
place starting at the bottom of the tank, and 
• 
Fill the tank with lightly compacted clean river sand and install a single layer of non-woven filter 
fabric against each drilled hole. 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DESIGN GUIDELINES 
WATER DISTRIBUTION 
SECTION 2.0 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
 
Section 2.0 - Water Distribution 
All Water Distribution requirements shall be confirmed with the Capital Regional District who is the 
water distribution system provider in the Town of View Royal. For all developments that include non- 
single family properties fire flow calculations must be submitted in accordance with the latest Fire 
Underwriters Survey with confirmation provided by the Capital Regional District that sufficient fire flow 
exists to protect the proposed development. 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DESIGN GUIDELINES 
SANITARY SEWERS 
SECTION 3.0 
PAGE 1 OF 3 
CONSOLIDATED TO MAY 2025 
 
Section 3.0 - Sanitary Sewers 
 
Off-site Sanitary Works and Services shall be designed and in conformance with the MMCD. 
Amendment Bylaw No. 1152, 2025 
 
 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DESIGN GUIDELINES 
SANITARY SEWERS 
SECTION 3.0 
PAGE 1 OF 3 
CONSOLIDATED TO MAY 2025 
 
Section 4.0 – Storm Drainage  
 
4.3.2 – Stormwater Design Criteria 
 
Replace the portion of Section 4.3.2.1 specifically describing the Minor System and Major System, with the 
following: 
 
Minor System – Consists of pipe, gutters, catch basins, driveway and local road culverts, local roadside 
ditches and open channels, to be designed to contain flows up to a 10-year return period to minimize 
inconvenience of frequent surface runoffs.  
 
All minor system components are to be sized to ensure that the hydraulic grade line of 10-year frequency 
flows remain below ground surface, and the flood protection elevation of dwellings, or within bank limits in 
the case of open channels and bio-swales.   
 
Major System – Consists of surface flood paths, roadways, trunk storm sewers and culvert crossings under 
collect roads, arterial roads and provincial highways, watercourses, and bypass structures for onsite and 
offsite stormwater management facilities, to be designed to safely convey design flows up to a 1:100-year 
return period, as directed by the Town, to minimize damage to life and property. 
 
4.3.4 
Climate Change Impact Considerations 
 
Add to the end of this section the following: 
 
The Engineer of Record shall disclose and describe the climate change approach used in the design of the 
storm drainage infrastructure. The “do nothing approach” is not accepted for permanent infrastructure. 
 
4.7 – Runoff Analysis Method 
 
Replace this section with the following:   
 
Rainwater management design should be carried out using one or more of the following methods as indicated 
below. Disclosure of methodology used and calculations must be submitted with designs. The Rainfall Intensity 
Duration curve is provided for reference in the figure below. 
 
• Rational Method:  Applicable in most cases for the purposes of conveyance design only and for areas less 
than 10 hectares in size. The rational method must not be used for designing retention or detention 
structures in any case, including but not limited to the development of flow rates, infiltration rates, and 
routed storage volumes.   
• Hydrograph Method:  Applicable for complex systems involving multiple catchments with highly variable land 
use conditions, where flow attenuation features are involved (e.g. detention pond, constructed wetland), or 
for gross areas exceeding 10 hectares.  Computer models shall be SWMM based, or as otherwise approved by 
the Town of View Royal.  
• Mass Balance: Volumetric based computations may be used to supplement flow analysis for the design of 
water quality treatment facilities and Best Management Practices intended for rainwater retention. 
 
Note:  Aside from the runoff analysis method applied, hydraulic grade lines and associated system performance 
shall consider governing downstream hydraulic boundary conditions, which may be available from the Town of 
View Royal.  If not available from the Town, or available to the degree necessary to support the design, 
additional off-site analysis may be required.   
Amendment Bylaw No. 1152, 2025 

STORM DRAINAGE 
SECTION 4.0 
CONSOLIDATED TO MAY 2025 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY DESIGN 
GUIDELINES 
 
Amendment Bylaw No. 1152, 2025 
 
 
 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY DESIGN 
GUIDELINES 
ROADS 
SECTION 5.0 
PAGE 1 OF 3 
CONSOLIDATED TO MAY 2025 
 
Section 5.0 – Roads 
5.3 – Cross-Section Elements 
Replace this section with the following: 
Recommended road cross sections elements are shown on the typical sections in the Town of View Royal 
Supplementary Detail Drawings (Schedule D). 
Right-of-way and pavement widths shown in the Town of View Royal Supplementary Design Guidelines 
(Schedule B) and the Town of View Royal Supplementary Detail Drawings (Schedule D) are subject to 
increases to accommodate the following: 
• 
Intersections 
• 
Turn lanes 
• 
Bike lanes 
• 
Bus bays 
Unless noted otherwise in Town of View Royal Supplementary Design Guidelines and Town of View Royal 
Supplementary Detail Drawings, or by condition of the Servicing Agreement, topsoil with sod and trees is 
required on medians and boulevards. Where the width is insufficient for maintenance of vegetation or 
ability to accommodate trees, concrete surfaces will be required. 
Note: Table 5.1, 5.2 and 5.3 have been omitted in lieu of the Town of View Royal Supplementary Detail 
Drawings. 
5.11.1 – Sidewalk 
Replace this section with the following: 
The requirement for sidewalks is as shown in the Town of View Royal Supplementary Detail Drawings. 
In the absence of specific local requirements, sidewalk details should be as follows: 
• 
Minimum width: 
1.5 m (excluding adjacent curb) 
• 
Cross-slope: 
2%, except at driveways and wheelchair ramps 
• 
Drainage: 
Towards gutter 
 
5.13 – Transit Facilities 
Replace this section with the following: 
The requirement for transit facilities will be established by the Town of View Royal, in consultation with 
BC Transit. 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY DESIGN 
GUIDELINES 
ROADS 
SECTION 5.0 
PAGE 2 OF 3 
CONSOLIDATED TO MAY 2025 
 
Bus bay locations should be established in cooperation with BC Transit. Bus bay details should be in 
accordance with the Pullouts section of the TAC Geometric Design Guidelines. It is assumed that local 
residential roads shall be serviced by community shuttle vehicles, while collector and arterial roads shall 
be serviced by full-sized City buses. 
Bus bays must be constructed as per the BC Transit Infrastructure Design Guidelines and include the 
following Portland cement pavement structure: 
 
• 
Portland Cement Concrete: 225mm 
• 
Base Course: 150mm 
• 
Subbase: 300mm 
Transit signs should be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD). 
 
Additional guidelines are included in BC Transit, Infrastructure Design Guidelines and Canadian Urban 
Transit Association, Canadian Transit Handbook. 
 
5.14.3 – Driveway Location and Width 
 
Replace this section with the following: 
 
Subject to providing adequate sight distance in accordance with TAC, driveway location and width shall 
conform to the following: 
a) The Driveway Crossing on any corner Parcel must be sited on the Street having the more minor street 
classification. 
b) The outer edge of a Driveway Crossing on any corner single-family residential Parcel cannot be located 
less than seven and one half (7.5) metres from the point of the Streets’ intersection. 
c) The outer edge of a Driveway Crossing on any corner commercial or multi-family Parcel cannot be 
located less than twelve (12.0) metres from the point of the Streets’ intersection. 
d) The outer edge of a Driveway Crossing shall not be closer than one and one half (1.5) metres to the 
extension of the adjoining lot boundary as if continued into the Town’s Street. 
e) The outer edge of a Driveway Crossing must be a minimum of three (3.0) metres from any tree unless 
root barriers are installed as approved by the Director. 
f) The outer edge of a Driveway Crossing must be a minimum of one and one half (1.5) metres from any 
above-ground utility equipment or street light. 
g) The surface of a Driveway Crossing must be a minimum of one (1.0) metre above underground utility 
equipment. 
h) A Driveway Crossing may be permitted to be constructed at the Owner’s cost over utility boxes if the 
casting of the utility box is of sufficient thickness to support the traffic that will be using the Driveway 
Crossing, and provided that the applicable utility company has provided written consent. 
i) 
The Director or Engineering may reduce the minimum clearances required in g) and h) above, if the 
applicable utility company has provided written consent. 
Amendment Bylaw No. 1014, 2019 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY DESIGN 
GUIDELINES 
ROADS 
SECTION 5.0 
PAGE 3 OF 3 
CONSOLIDATED TO MAY 2025 
 
5.14.4 – Driveway Grades 
Replace this section with the following: 
Refer to VRSD-R18 for grades and level distance. 
Amendment Bylaw No. 1014, 2019 
5.17.3 – Pavement Alternatives 
Add the following to the end of this section: 
 
The pavement alternatives are minimum standards only. Subgrade soil conditions must be verified by a 
qualified geotechnical engineer and the subgrade stiffness must be verified by proof roll prior to 
implementing the minimum standards. Alternatively, site-specific road structures should be designed by 
a qualified geotechnical engineer. 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY DESIGN 
GUIDELINES 
LANDSCAPE 
SECTION 12.0 
PAGE 1 OF 3 
CONSOLIDATED TO MAY 2025 
 
Section 12.0 – Landscape Requirements 
12.1 - Plans 
 
Designs and drawings shall be prepared and sealed by a Landscape Architect currently registered in British 
Columbia. Plans shall clearly show all survey, existing and proposed soft and hard landscape features and 
all existing and proposed roads and above ground services. 
Plans shall be at minimum 1:200 [1/16” = 1’-0”] scale and shall include cross-sections and sight clearance. 
Landscape plans must clearly show: 
- 
Materials and character of the surface treatment at entire site. 
- 
Planting plan and a plant list. Planting plan shall indicate the general planted size and spacing of 
plants. Plant list shall document quantity, scientific and common name, and scheduled size of 
plants at the time of planting. 
- 
Existing trees to be retained / removed. Tree protection strategy during construction shall be 
noted. Refer to section 8.3 of this document for further information regarding existing tree 
retention. 
- 
Hard landscape features, e.g., paving, walls, lighting, fencing, furniture, signage, trellis, water 
feature, drainage, etc. Materials for such hard landscape features shall be clearly indicated. 
- 
Grading at entire site, including location and elevation of all area drains in hard landscape, storm 
drainage swales, lawn basins in soft landscape areas. 
 
12.2 – Boulevard Trees 
 
Tree selection, handling, planting and maintenance must meet the current editions of BCSLA/BCLNA 
Landscape Standards and the CNTA Nursery Stock Standard, be in good health and condition without 
wounds, have normal form, and be free of diseases and pests. 
 
All tree root balls and pots to be free of noxious weeds. 
 
All trees of excurrent genera to have single leaders (no trees with co-dominant stems permitted). 
All trees to have encircling/girdling roots removed at the time of planting. 
All tree species are to be approved by the Director of Engineering, or designate, and be a minimum of 6cm 
caliper, branched at or above 1.3m if deciduous, or 3m in height if coniferous. No pruning of the scaffold 
branches or leader should be undertaken; only broken branches should be pruned. 
 
Protect tree from danger during planting. Ensure root ball is protected from sun, frost or desiccation. 
Planting 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY DESIGN 
GUIDELINES 
LANDSCAPE 
SECTION 12.0 
PAGE 2 OF 3 
CONSOLIDATED TO MAY 2025 
 
Planting holes must be free draining to the extent that rainwater and/or supplemental water does not 
accumulate and drown the roots. If necessary, the subgrade must be graded with positive slope and/or 
drainage services such as but not limited to percolation holes, french drains or drain pipes must be 
installed to suit. 
 
Watering of the root ball must be undertaken immediately after planting and then for the first growing 
season so that the root ball is thoroughly wetted once per week (minimum). 
 
The tree should be pruned to ANSI A3000 standards after establishment and from time to time to train it 
for structure to conform to the form of the species and to respond to growing site constraints. All pruning 
must be undertaken by or performed under the direction of a qualified arborist certified by the 
International Society of Arboriculture and who demonstrates proficiency in pruning. 
 
The mulched root zone should be refreshed annually to replace the mulch. This area must be weeded by 
hand to avoid trunk and root damage from string trimmers or mowers. 
 
In situations where designed boulevard area does not provide adequate rooting volume, structural soil 
and/or Silva Cells may be utilized to provide further soil volume. Silva Cells are considered an experimental 
product at the time of publication of this manual. The use of Silva Cells must be approved by the Town of 
View Royal prior to installation on public property. Design and installation techniques are to be provided 
by Silva Cell suppliers and approved by the Town of View Royal. 
 
Root barriers must be installed at the time of planting whenever a tree is installed within 2 metres of a 
sidewalk or other hardscape features, excluding roads; or where specified on approved drawings. Barriers 
must be made commercially, produced for the purpose of deflecting roots downward, and be of a 
specification approved by the Town of View Royal. Placement of root barriers must be as per 
manufacturer’s instructions. 
 
Tree Spacing 
Boulevard trees are to be spaced at 8-10m [26’-33’] on centre. 
 
Clearances 
The following table is the guidelines for minimum clearances for all of boulevard trees. Clearances shall 
be measured from the closest edge of the listed items to the centre of tree: 
 
Light Standards 
4 metres 
Electrical / Communication Poles 
1.5 metres 
Driveways / Crossings 
2 metres 
Fire Hydrants 
1.8 metres 
Corner Clearance (from extended property line) 
3 metres 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY DESIGN 
GUIDELINES 
LANDSCAPE 
SECTION 12.0 
PAGE 3 OF 3 
CONSOLIDATED TO MAY 2025 
 
 
Stop Signs 
6 metres 
Manholes, Valve Boxes, Service Kiosks 
1.5 metres 
 
 
12.3 – Tree Retention 
 
All of the existing trees that are 20cm DBH (Diameter Breast Height) or more must be surveyed and 
assessed by certified Arborists. Landscape plans shall clearly indicate whether such trees are to be 
retained or removed. Tree protection zones during construction shall be consulted with certified Arborists 
and shown on plans. 
 
Retention of existing trees is encouraged in park lands and in areas that do not require major re-grading. 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
CONSOLIDATED TO MAY 2025 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SCHEDULE C 
SUPPLEMENTARY CONSTRUCTION SPECIFICATIONS 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
GENERAL DESCRIPTION 
 
SUPPLEMENTARY SPECIFICATIONS GENERAL USE DESCRIPTION 
This schedule contains supplementary specifications to be applied in conjunction with the Specifications 
of the Master Municipal Construction Documents, dated 2009, both of which shall apply to all Works 
and Services constructed within the Town of View Royal. 
Supplementary Specifications contained within this Schedule supplement or supersede the Master 
Municipal Construction Document (MMCD). Where the Town of View Royal Supplementary 
Specifications are in conflict with the MMCD, the Town of View Royal Supplementary Specifications shall 
take precedence. 
Section number and clause numbers in the Town of View Royal Supplementary Specifications coincide 
with the MMCD numbering protocol. 
 
 
Table of Contents 
Section 
Description 
 
32 91 21 
Topsoil and Finish Grading 
32 92 19 
Hydraulic Seeding 
32 92 20 
Seeding 
32 92 23 
Sodding 
32 93 01 
Planting of Trees, Shrubs and Groundcovers 
 
33 11 01 
Waterworks 
33 30 01 
Sanitary Sewers 
33 34 01 
Sewage Forcemains 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
SECTION 32 91 21 
PAGE 1 OF 2 
CONSOLIDATED TO MAY 2025 
TOPSOIL AND FINISH GRADING 
 
 
Section: 
Description: 
 
 
1.3 
Source Quality 
Control 
 
- 1.3.2 VRSS 
Delete clause 1.3.2 and substitute the following: 
 
Contractor is responsible to provide to Contract Administrator a soils 
test commissioned by the contractor specifically for this project. Soils 
analyses commissioned by the soils manufacturer will not be accepted. 
The Contract Administrator will designate the soil testing laboratory. 
Contractor is responsible for arrangement and payment for soil 
analysis and amendments to growing medium as determined. 
Contractor shall instruct soil testing laboratory to submit results directly 
to the Contract Administrator prior to commencement of work. The 
recommendations of the laboratory will be the basis of requirements for 
soil acceptance and soil amendments. 
 
- 1.3.3 VRSS 
Add clause 1.3.3: 
 
Growing medium shall meet BCSLA/BCLNA Landscape Standard, 
latest edition, unless otherwise specified. 
 
 
- 1.3.4 VRSS 
Add clause 1.3.4: 
Contractor is responsible to provide to Contract Administrator a soils 
test commissioned by the contractor specifically for this project. Soils 
analyses commissioned by the soils manufacturer will not be accepted. 
The Contract Administrator will designate the soil testing laboratory. 
Contractor is responsible for arrangement and payment for soil 
analysis and amendments to growing medium as determined. 
Contractor shall instruct soil testing laboratory to submit results directly 
to the Contract Administrator prior to commencement of work. The 
recommendations of the laboratory will be the basis of requirements for 
soil acceptance and soil amendments. 
 
- 1.3.5 VRSS 
Add clause 1.3.5: 
 
Contractor to provide separate soils test(s) for all soil deliveries over 30 
days apart. See testing requirements above (1.3.4) 
 
- 1.3.6 VRSS 
Add clause 1.3.6: 
 
The Contractor shall guarantee that the growing medium submitted for 
laboratory analysis will be a representative sample of the growing 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
SECTION 32 91 21 
PAGE 2 OF 2 
CONSOLIDATED TO MAY 2025 
TOPSOIL AND FINISH GRADING 
 
medium delivered to the site. The Contractor shall provide receipts 
upon request of the Contract Administrator. 
 
- 1.3.7 VRSS 
Add clause 1.3.7: 
 
Imported soils to be free of weeds and weed seeds. Contractor will be 
responsible for the removal and replacement of approved soils at no 
cost to the owner. 
- 1.3.8 VRSS 
Add clause 1.3.8: 
 
At the discretion of the project Contract Administrator submit up to two 
additional samples at intervals outlined by the Contract Administrator of 
growing medium taken form material delivered to site. Samples shall 
be taken from three (3) random locations and mixed to create a single 
uniform sample for review. 
 
- 1.3.9 VRSS 
Add clause 1.3.9: 
 
Failure to have the growing medium tested as indicated above may 
result in the removal of substandard soils at the Contractor’s expense. 
1.4 
Measurement 
and Payment 
 
- 1.4.4 VRSS 
Add clause 1.4.4: 
 
Contractor to account for additional growing medium required as a 
result of settlement. 
 
 
 
END OF SECTION 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
SECTION 32 92 19 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
HYDRAULIC SEEDING 
 
Section: 
Description: 
 
1.2 
References 
 
- 1.2.1 VRSS 
Delete clause 1.2.1 and replace with the following: 
Current Edition of British Columbia Landscape Standard 
 
1.6 
Samples 
 
- 1.6.2 VRSS 
Add clause 1.6.2: 
 
Contractor to provide cut sheets and seed analysis of approved mixes 
prior to delivery to site 
 
2.1 
Grass Seed 
 
- 2.1.3 VRSS 
Delete clause 2.1.3 and replace with the following: 
 
Seed to have a minimum germination rate of 80% and minimum purity 
of 97% except where otherwise required by professional selecting seed 
mixture. 
 
 
 
 
END OF SECTION 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
SECTION 32 92 20 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
SEEDING 
 
 
Section: 
Description: 
 
1.2 
References 
- 1.2.1 VRSS 
Delete clause 1.2.1 and replace with the following: 
 
Current Edition of British Columbia Landscape Standard 
 
1.6 
Samples 
 
- 1.6.2 VRSS 
Add clause 1.6.2: 
 
Contractor to provide cut sheets and seed analysis of approved mixes 
prior to delivery to site. 
 
1.9 
Inspection and Testing 
 
- 1.9.2 VRSS 
Add clause 1.9.2: 
 
Finished grade to be approved prior to seeding, refer to section 31 22 
01 Site Grading. 
 
2.1 
Grass Seed 
 
- 2.1.3 VRSS 
Delete clause 2.1.3 and replace with the following: 
Seed to have a minimum germination rate of 80% and minimum purity 
of 97% except where otherwise required by professional selecting seed 
mixture. 
 
 
END OF SECTION 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
SECTION 32 92 23 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
SODDING 
 
 
Section: 
Description: 
 
1.4 
Handling 
and Storage 
 
- 1.4.3 VRSS 
Delete clause 1.4.3 and replace with the following: 
 
No storage of unused sod overnight during growing season. 
 
1.6 
Samples 
 
- 1.6.2 VRSS 
Delete clause 1.6.1 and replace with the following: 
 
 
 
2.1 
Sod 
Contractor to provide name of supplier and seed analysis for approval 
a min. of 48 hours prior to delivery to site. 
 
- 2.1.2 VRSS 
Delete clause 2.1.2 and replace with the following: 
 
Sod to be suitable for high traffic areas, offer good wear tolerance, 
shall be grown on sand or sandy loam based medium and shall be un- 
netted from approved supplier, see section 1.6.2 above. 
 
.1 Sod cut size typical unless stated otherwise in contract 
documents, such as areas where large roll applications are 
desired. 
 
 
END OF SECTION 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
SECTION 32 93 01 
PAGE 1 OF 3 
CONSOLIDATED TO MAY 2025 
PLANTING OF TREES, SHRUBS AND 
 
GROUNDCOVER 
 
 
 
Section: 
Description: 
 
 
1.3 
Source Quality 
Control 
1.3.1 VRSS 
Delete clause 1.3.1 and replace with the following: 
Obtain approval from Contract Administrator of plant material at source 
prior to shipping. Acceptance of plant material at its source does not 
prevent rejection on site prior to or after planting operations. 
1.3.3 VRSS 
Add clause 1.3.3: 
All materials and execution to conform to the latest edition of the 
BCLNA (BC Landscape and Nursery Association) and BCSLA 
Landscape Standard. 
1.3.4 VRSS 
Add clause 1.3.4: 
Trees delivered to site to be from nursery with current certification for 
Phytophthora. 
1.3.5 VRSS 
Add clause 1.3.5: 
All root balls to be free of invasive and weed species. Contractor 
responsible for removal and replacement at their cost of all plant stock 
and effected soil to be found contaminated. 
1.3.6 VRSS 
Add clause 1.3.6: 
Plant substitutions require a minimum of 2 months’ notice in writing for 
all Tree, Shrub, and Groundcover Species. All substitutions to be 
approved by project Contract Administrator. 
1.3.7 VRSS 
Add clause 1.3.7: 
Plant specimen search to extend a minimum area to extend to British 
Columbia, Washington State and Oregon State. 
1.4 
Scheduling 
 
- 1.4.3 VRSS 
Delete clause 1.6.1 and replace with the following: 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
SECTION 32 93 01 
PAGE 2 OF 3 
CONSOLIDATED TO MAY 2025 
PLANTING OF TREES, SHRUBS AND 
 
GROUNDCOVER 
 
 
Plan, schedule and execute work to ensure a continuous supply of 
water for landscape purposes in adequate amounts and at adequate 
pressures for satisfactory irrigation of all plants from time of delivery 
until total performance if not responsible for maintenance thereafter. 
 
1.5 
Handling and 
Storage 
 
- 1.5.5 VRSS 
Add clause 1.5.5: 
 
Immediately store and protect plant material that will not be installed 
within 2 hours after arrival. 
 
- 1.5.6 VRSS 
Add clause 1.5.6: 
 
Protect stored plant material from frost, wind and sun and as follows: 
.1 
For bare root plant material preserve moisture around roots by 
heeling-in or burying roots in topsoil and watering to full depth of 
root zone. 
.2 
For pots and containers maintain moisture level in containers. 
Heel-in fibre pots. 
.3 
For balled and burlapped and wire basket root balls, place to 
protect branches from damage. Maintain moisture level in root 
zones. 
 
1.8 
Site Examination 
 
- 1.8.2 VRSS 
Add clause 1.8.2: 
 
Verify existence and location of any on-site utilities. Contact the 
contract administrator immediately for directions as to procedure 
should any piping or utilities be encountered during excavation. 
1.10 Inspection 
and Testing 
 
- 1.10.2 VRSS 
Add clause 1.10.2: 
 
Notify Contract Administrator when plants are available for inspection. 
All plants are subject to inspection and may be rejected for failure to 
comply with this specification at any time until total performance. 
Remove and replace rejected material at no cost to owner. 
 
- 1.10.3 VRSS 
Add clause 1.10.3: 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
SECTION 32 93 01 
PAGE 3 OF 3 
CONSOLIDATED TO MAY 2025 
PLANTING OF TREES, SHRUBS AND 
 
GROUNDCOVER 
 
 
Tagged plant material selected and tagged at nursery to remain tagged 
until plants have been inspected onsite and approved by project 
Contract Administrator. 
 
- 1.10.4 VRSS 
Add clause 1.10.4: 
 
Subsequent site inspections to review transplanted and supplied 
materials will be performed over the duration of the contract. 
 
- 1.10.5 VRSS 
Add clause 1.10.5: 
 
Final inspection to be made at the end of warranty period as specified. 
For release from contract all material must be alive and in a healthy 
growing condition at the time of the inspection. 
 
- 1.10.6 VRSS 
Add clause 1.10.6: 
 
Project Contract Administrator may waive one or more inspections at 
their discretion, such actions will not impair the right of the project 
Contract Administrator to inspect work or materials which have been 
damaged or in any way do not conform to contract documents. 
 
 
END OF SECTION 

SECTION 33 11 01 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
WATERWORKS 
 
 
 
Section 
Description 
Refer to Capital Regional District (CRD) Supplementary 
Specifications for Waterworks, as applicable. 
END OF SECTION 

SECTION 33 30 01 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
SANITARY SEWERS 
 
 
 
Section 
Description 
2.0 
PRODUCTS 
2.1 
General 
- 2.1.3 VRSS 
Add clause 2.1.3 
Refer to Schedule E – Approved Products List. 
2.2 
Plastic Pipe, Mainline 
Smooth Profile 
- 2.2.6 VRSS 
Add clause 2.2.6 
Pipe joints shall be restrained non-metallic joints, Cobra Lock or 
approved equal. 
END OF SECTION 

SECTION 33 34 01 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
SEWAGE FORCEMAINS 
 
 
 
Section 
Description 
2.0 
PRODUCTS 
2.1 
General 
- 2.1.3 VRSS 
Add clause 2.1.3 
Refer to Schedule E – Approved Products List for pipe material. 
2.2 
Pipe, Joints and 
Fittings 
- 2.2.3 VRSS 
- 2.2.5 VRSS 
Delete 2.2.3 and substitute the following: 
Refer to the Approved Products List for pipe joints. 
Delete 2.2.5 and substitute the following: 
Refer to the Approved Products List for pipe fittings. 
END OF SECTION 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DETAIL DRAWINGS 
CONSOLIDATED TO 
MAY 2025 
 
 
SUPPLEMENTARY DETAIL DRAWINGS 
This schedule contains supplementary detail drawings to be applied in conjunction with the Standard 
Detail Drawings of the Master Municipal Construction Documents, dated 2009, both of which shall apply 
to all Works and Services constructed within the Town of View Royal. 
 
Supplementary Detail Drawings contained within this Schedule supplement or supersede the Master 
Municipal Construction Document (MMCD). Where the Town of View Royal Supplementary Detail 
Drawings are in conflict with the MMCD, the Town of View Royal Supplementary Detail Drawings shall 
take precedence. 
 
Drawing numbers in the Town of View Royal Supplementary Detail Drawings coincide with the MMCD 
numbering protocol. 
 
Table of Contents 
 
Detail Drawing 
Description 
VRSD-C7a 
Typical Driveway Crossing Type “A” 
VRSD-C7b 
Typical Driveway Crossing Type “B” 
VRSD-C7c 
Typical Driveway Crossing Cross Sections 
VRSD-G5a 
Limits of Pavement Construction 
VRSD-L1 
Tree Protection Detail 
VRSD-L2 
Boulevard Tree Planting Detail 
VRSD-L3 
Rock Retaining Wall (Gravity) 
VRSD-L4 
Plant Pockets in Rock Wall 
VRSD-L5 
Concrete Retaining Wall Installation 
VRSD-R2 
Speed Table – Raised Crosswalk 
VRSD-R3 
Speed Table – Emergency Vehicles 
VRSD-R4 
Sign Post Installation - 1 of 2 
VRSD-R5 
Sign Post Installation - 2 of 2 
VRSD-R6 
Street Name Blade 
VRSD-R7 
Local 14m ROW - Rural 
VRSD-R8 
Local 14m ROW - Urban 
VRSD-R9 
Local 18m ROW - Rural 
VRSD-R10 
Local 18m ROW – Urban Class A 
VRSD-R11 
Local 18m ROW – Urban Class B 
VRSD-R12 
Collector 20m ROW – Rural 
VRSD-R13 
Collector 20m ROW – Urban Class A 
VRSD-R14 
Collector 20m ROW – Urban Class B 
VRSD-R15 
Major 20m ROW – Urban 
VRSD-R16 
Major 30m ROW – Urban 
VRSD-R17 
Sidewalk Driveway Crossings 
VRSD-R18 
Driveway Grades 
VRSD-R19 
Sight Line Setbacks 
VRSD-R20 
Sample Site Servicing Plan 

 
 

 
 

 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
IF LESS THAN 1.30m THEN REMOVE ENTIRE 
PAVEMENT TO LIP OF GUTTER AND REPLACE 
 
WHERE BIKE LANES EXIST, TO BIKE 
LANE PAVEMENT MARKINGS.\ 
SEE STANDARD DETAIL 
DRAWING G5 IN MMCD 
FOR PAVEMENT 
RESTORATION 
 
 
 '  1.30m 
 
 
 
 
 
呸 
 
EXISTING PAVEMENT 
 
 
SEE STANDARD DETAIL 
DRAWING G4 IN MMCD 
FOR TRENCH CONDITIONS 
ABOVE THE PIPE ZONE 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(J) 
0 
N 
 
LIMITS OF PAVEMENT RESTORATION 
DRAWING NUMBER 
VRSD-G5a 
REVISION NUMBER 
 
SCALE 
NTS 
_) 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
TREE 
PROTECTION 
AREA 
NO ENTRY 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
ISLAND 
HWY 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
BARKER RD 
NO 
EXIT 
 
6" VIEW ROYAL STREET BLADE 
MAIN FONT - 3.875" HELVETICA COMPACT - FORCED 80% (LENGTH) 
NO EXIT FONT - 
1.65" HELVETICA MEDIUM - FORCED O (NONE) 
 
CARLY LN 
NO 
PRIVATE ROAD 
EXIT 
 
 
9" VIEW ROYAL STREET BLADE 
MAIN FONT - HIGHWAY GOTHIC "B" - FORCED O (NONE) 
PRIVATE ROAD FONT - HIGHWAY GOTHIC "E/M" - FORCED O (NONE) 
NO EXIT FONT - 2.33" HELVETICA MEDIUM - FORCED O (NONE) 
 
 
 
 
 
 
STREET BLADE SPECIFICATIONS: 
ALUMINUM, EXTRUDED EDGES TOP & BOTTOM, PRINTED ON WHITE EG REFLECTIVE VINYL. 
BLUE - PANTONE 282c @ 70% / DOUBLE PRINT (HIT) 
YELLOW -  GERBER YELLOW GCS-015 @ 100% DOUBLE PRINT 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
a, 
I 
a
-st­ 
I 
0 
N
N
<.D
 
STREET NAME BLADE 
DRAWING NUMBER 
VRSD-R6 
REVISION NUMBER 
1 
SCALE 
NTS 

 
TOWN OF VIEW ROYAL 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
TABLE OF WIDTHS FOR DRIVEWAY CROSSINGS 
LAND USE 
STREET 
CLASSIFICATION 
DRIVEWAY 
TYPE 
CROSSING 
WIDTH(w) 
*MIN 
*MAX 
COMMERCIAL 
/ INDUSTRIAL or 
MULTI-FAMILY 
RESIDENTIAL 
ALL 
B 
5.0m 
IO.Om 
RESIDENTIAL 
MAJOR 
A 
5.0m 
7.0m 
RESIDENTIAL 
COLLECTOR/ 
LOCAL 
A 
3.0m 
7.0m 
ALL 
ALL 
C 
5.0m 
IO.Om 
 
 
 
 
 
 
 
 
FOR TYP. FLARE 
DEPTH REFER 
TO NOTES 
r--w--j 
i----w ----------------i 
 
 
 
 
L 
I 
w --- 1 
REFER TO NOTE 2 (TYP) 
TYPE' A' 
 
 
 
DEP'
TH 
 
 
 
·' 
 
 
 
 
 
 
 
 
 
 
 
 
w+2.0 
TYPE'B' 
 
 
 
 
 
 
 
 
 
J LFACE OF CURB 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1------1-呸-- w ------------- l 
 
 
TYPE' C' 
(DIRECTIONAL) 
 
 
 
 
NOTES: 
I 
FLARE DEPTHS SHALL BE 3.0m UNLESS OTHERWISE APPROVED BY THE DIRECTOR 
2 
FLARE WIDTHS SHALL CONFORM TO VRSD C7a OR C7b UNLESS OTHERWISE 
APPROVED BY THE DIRECTOR 
3 
FOR CONSTRUCTION DETAILS REFER TO VRSD-C7c 
 
 
 
 
 
 
 
 
 
 
 
 
 
(J) 
0 
N 
 
DRIVEWAY WIDTHS 
DRAWING NUMBER 
VRSD-R17 
REVISION NUMBER 
 SCALE 
NTS _) 

 
-, 
n 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
I.Om 
GARAGE FLOOR 
 
 
 
LEVEL DISTANCE 
EQUAL IN ELEVATION 
\ 
c-9= ------- J 
\_EXISTING PAVEMENT - 
- 
 
FUTURE STDEWALK AND CURB 
 
. .....  
 
GARAGE FLOOR 
 
 
 
DRIVEWAY GRADE* 
 
RISE ORF ALL 
I .Om 
 
 
 
 
 
 
 
 
NOTES: 
l. TO ALLOW FOR FUTURE ROAD WIDENING AND SIDEWALK CONSTRUCTION, THE DRIVEWAY AND FINISHED 
BOULEYARD GRADE MUST BE AT THE SAME ELEVATION AS THE CENTRE OF THE EXISTING ROAD SURFACE 
AT THE FOLLOWING LEVEL DISTANCE FROM THE PAVEMENT CENTRELINE AS PER THE TABLE BELOW. 
2. 
MAXIMUM DRlVEWAY GRADES ARE AS NOTED BELOW OR AS REQUIRED UNDER THE BC FIRE CODE, WHICH 
EVER IS LESS. 
 
ROAD CLASSIFICATION 
MINIMUM LEVEL DISTANCE 
* MAXIMUM DRlVEWA Y GRADE 
RESIDENTIAL ROADS 
7.5m 
12% 
COLLECTOR ROADS 
8.5m 
12% 
MAJOR ROADS 
TO BE DETERMINED BY THE DIRECTOR 
10% 
3. 
WHERE THE CENTRE OF THE EXISTING ROAD SURFACE IS MORE THAN l.Sm OFF OF THE CENTRE OF THE 
ROAD ALLOWANCE, MEASURE THE LEVEL DISTANCE FROM THE CENTRE OF THE ROAD ALLOWANCE 
4. 
EXCEPTIONS TO THESE STANDARDS MAY BE ALLOWED ONLY AT THE DISCRETION OF THE DIRECTOR. 
 
 
 
 
 
 
 
 
 
 
(J) 
0 
N 
 
DRIVEWAY GRADES 
DRAWING NUMBER 
VRSD-R18 
REVISION NUMBER 
 SCALE 
NTS _) 
r
l

 
呸------------------ 
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
 
 
 
 
 
 
 
 
 
 
DRIVEWAY 
 
 
 
 
 
I/ 
SIGHT TRIANGLE呸 
 
 
 
I 
*_
0I
.45 
 
I 
I 
I 
I 
: 
3.0 
I 
I 
I 
..
I. 
45° 
I 
t 
]-' 
3.0 
 
I 
I 
I 
I 
I 
I 
I 
I 
I 
呸
I 
1 
I 
I 
L STREET BOUNDARY 
 
 
STREET 
 
 
 
 
 
 
 
 
 
 
* 
A PERSON SHALL NOT PLANT ANY TREE, SHRUB, BUSH OR 
HEDGE CLOSER THAN 0.45m TO THE STREET BOUNDARY 
* 
STRUCTURES, SUCH AS A FENCES OR SIGNS, SHALL NOT 
BE HIGHER THAN 1.2m HIGH WHEN PLACED IN THE SIGHT 
TRIANGLE. 
 
 
 
 
 
 
 
 
 
 
 
(J) 
0 
N 
 
SIGHT LINE SETBACKS 
DRAWING NUMBER 
VRSD-R19 
REVISION NUMBER 
 
SCALE 
NTS 
_) 

 
\ 
"
TOWN OF VIEW ROYAL 
SUPPLEMENTARY STANDARD DETAIL DRAWING 
DIM 
1 
 
 PROPERTY LINES 
2 
0 
 
 
 
 
l 
 
DIM 
 
1-- 
 
ADDRESS: 
LOT: 
BLOCK 
PLAN: 
 
 
 
 
 
 
 
 
 
 
 
(!) 
;;c 
Q:'. 
<( 
Q_ 
 
 
 
 
 
 
 
 
 
<( 
w 
Q:'. 
<( 
RESIDENCE 
 
 
 
 
FORMER 
GARAGE 
2 
0 
 
 
 
 
 
 
 
 
DIM 
--1 
 
w 
2 
<( 
z 
f­ 
w 
w 
0::: 
f­ 
(/) 
 
>-­ 
<( ,;: 
is; 
Q:'. 
0 
>-­ 
<( 
,;: 
_J 
<( 
,;: 
SEEN  E 4  
 
 
DIM 
 
 
 
 
 
DRIVEWAY CROSSING 
TO BE REMOVED 
 
SEE NOTE 4 
BOULEVARD 
SEE NOTE 4 
SIDEWALK 
DIM 
2 
0 
. I 
 
 
PROPERTY LINES 
 
-POWER/TEL- - 
BOULEVARD 
 
NEW DRIVEWAY 
CROSSING 
 
 
I I 
·j-1· -WATER (W)- 
·-· - 
STREET NAME 
j I 
- - -  - - -  - - - .L -STORM DRAIN (D)-  -  -  - 
· - 
- 
- 
- 
- 
- 
- 
-  · j_  - 
-SEWER (S)- -  - 
 
 SITE SERVICING PLAN 
SCALE: 1: 1 00 
 
NOTES: 
 
1. DIMENSIONS (DIM) TO BE SHOWN IN METRES. 
2. ON SITE PARKING LOCATION AND DIMENSIONS 
TO CONFORM TO THE ZONING BYLAW. 
3. SITE SERVICING PLAN MAY BE COMBINED WITH 
THE SITE PLAN PROVIDED ALL INFORMATION FOR 
BOTH PLANS IS SHOWN. 
4. REFER TO SCHEDULE B 
5. STORMWATER MANAGEMENT TO BE DESIGNED, 
SIZED, AND LOCATED BY A CONSULTING ENGINEER. 
 
 
SAMPLE SERVICING SITE PLAN 
a, 
0 
N 
 
 
LEGEND: 
X 
SPOT ELEVATION 
• 
INSPECTION CHAMBER 
e 
WATER METER 
 
 
 
 
DRAWING NUMBER 
VRSD-R20 
REVISION NUMBER 
 
SCALE 
NTS _) 
◊ N 
-
z 
- 
- 
-  I_ 
呸I 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
NOVEMBER 2017 
 
SCHEDULE E 
Approved Products List 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
SPECIFICATIONS 
PAGE 1 OF 1 
CONSOLIDATED TO MAY 2025 
APPROVED PRODUCTS LIST 
 
 
 
MMCD Ref 
(2009 
Platinum) 
Product 
Approved 
Material/Type 
Approved Product 
Restrictions/Additional 
Specifications 
26 56 01 
Roadway 
Lighting 
Ornamental 
Lighting 
• To be 
confirmed by 
the Town of 
View Royal 
33 11 01 
Waterworks 
Refer to Capital Regional District (CRD) Specifications 
33 30 01 
Sanitary 
Sewers 
Plastic Pipe, 
Mainline 
Smooth 
Profile 
• Gasketed PVC 
33 34 01 
Sewage 
Forcemains 
Pipe, Joints 
and Fittings 
• Restrained 
PVC 
• HDPE 
• Cobralock or 
approved equal 
• Sclairpipe or 
approved equal 
• 
All PVC pipe to be 
restrained non- 
metallic joints 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DRAWING STANDARDS 
Consolidated to MAY 2025 
 
SCHEDULE F 
SUPPLEMENTARY DRAWING STANDARDS 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DRAWING STANDAND 
PAGE 1 OF 10 
CONSOLIDATED TO MAY 2025 
 
 
 
TOWN OF VIEW ROYAL 
DESIGN DRAWING SPECIFICATIONS 
 
Table of Contents 
Page 
Section 1.0 - General 
2 
Section 2.0 - Design Drawings 
2 
Section 3.0 - Record Drawings 
8 
 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DRAWING STANDAND 
PAGE 2 OF 10 
CONSOLIDATED TO MAY 2025 
 
Section 1.0 - General 
1.2 
The Drawing Specifications apply to the design of sanitary sewers, storm drains, 
boulevards, roadways, and street lighting, within the Town of View Royal. They also apply 
to the location and coordination of the other utilities within the Town of View Royal. 
1.3 
Departure from the Drawing Specifications is not permitted without the prior written approval 
of the Director of Engineering. 
1.4 
Any information received from the Town of View Royal about existing services shall be used 
as a guide only. The Town of View Royal has no responsibility for the exactness of service 
information obtained from the GIS, drawings and information provided electronically. The 
Applicant should confirm underground locations with utility companies and should verify the 
locations and elevations of all existing services by actual survey. 
 
 
Section 2.0 - Design Drawings 
2.1 
Electronic Drawings Standards 
All design drawings shall be created using software which is compatible with 
AutoCAD, release 2014 or later. 
Circulation submissions shall be on paper prints. Four copies of the final design 
submissions shall be in black, on paper, suitable for photocopying, signed and 
sealed by the Consulting Engineer. Sealed design drawings will be returned to 
the Consulting Engineer once they have been signed by the Town of View 
Royal and sufficient copies have been made. 
2.2 
Sheet Sizes 
2.2.1 
Standard sheet size is A1 metric size 594 mm x 841 mm. 
 
2.3 
Plan/ Profile Layouts 
The profile view shall be aligned above the plan view on the same drawing 
sheet. 
The use of plan on one sheet and profile on a second sheet is not acceptable. 
A north arrow, generally orientated towards the top of the sheet, shall be shown 
on the design drawing. 
Construction notes shall be confined to a separate “note” column, wherever 
possible, with numbered references in a plan or profile. 
 
2.4 
Scales 
 
 
 
 
All scales shall be standard metric scales 
Normal: Horizontal 1:250 or 1:100 Vertical 1:50 
Not to Scale details shall be avoided 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DRAWING STANDAND 
PAGE 3 OF 10 
CONSOLIDATED TO MAY 2025 
 
2.5 
Proposed and Existing Services 
Proposed construction and improvements shall be shown as heavy solid lines. 
Proposed future construction shall be shown as heavy dashed lines. Existing 
works and services shall be shown as solid lines and shall be screened to 60% 
or else drawn with fine lines to create the same effect as screening. 
Existing water mains, sanitary sewers, and storm drains (including all 
appurtenances), as well as ditches, pavement, curbs, sidewalks, underground 
wiring, gas, poles, trees, service connections and other underground utilities 
shall be indicated in plan and profile where applicable. 
All services shall generally be shown on one plan with curbs (mountable or non- 
mountable), sidewalks, sewers, drains, gas, water and street lighting 
(underground wiring), fibre optics, BC Hydro and telecommunications (by 
company) including poles; identified as MC or NMC, S/W, S, D, G, W, L, FO, H, 
or (T-TELUS, S-Shaw) respectively. Other services shall be clearly designated 
on the drawing. 
Dimensions of drawings shall be given from an existing monument or pin or 
proposed iron pin or lot line. Road chainage shall be tied to a monument or iron 
pin from the start of construction. All chainage shall be positive values with 0+0 
located adjacent to the left margin of the drawing sheet. Subsequent chainages 
shall increase from the left margin towards the right border of each drawing 
sheet. All proposed works and services shall be fully dimensioned. 
Connections or alterations to existing sanitary sewers and storm drains by the 
Town of View Royal shall be indicated on the design drawings. 
Existing detail information shall include: 
(a) All surface and subsurface infrastructure and natural features within the road 
allowance or project site. 
(b) All surface and subsurface infrastructure and natural features outside the 
road allowance or project site that influences or may be impacted by the 
proposed work and services. 
2.6 
Elevations and Vertical Datum 
Vertical control shall be shown in metric geodetic datum (mean sea level = 0). 
Bench mark numbers, locations and elevations can be obtained from Base 
Mapping & Geomatic Services Branch of the Integrated Land Management 
Bureau (ILMB) of the Ministry of Agriculture and Lands. The reference bench 
mark numbers and elevation shall be shown on the design drawings. 
Elevations below zero (0) metres geodetic shall be prefixed with a minus sign. 
The design drawings shall show: 
(a) the elevation, to the nearest centimetre, 
(b) existing basement floors and, 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DRAWING STANDAND 
PAGE 4 OF 10 
CONSOLIDATED TO MAY 2025 
 
(c) 
where the building site is less than 1m above the road level, any proposed 
basement floor elevation or entrance, 
(d) Critical elevations at property lines i.e. Doorways and Driveways. 
If a subdivision lot is proposed to be filled, the drawings shall show existing 
ground elevations at corners of the allowable building envelope or show a 
centre of lot profile, to indicate the extent of fill required. The placement of fill 
must be done under the direct supervision of Consulting Engineer and the 
Owner shall supply a signed and sealed report from the Consulting Engineer 
attesting to the suitability of the placed fill for building. 
2.7 
Requirements for Key Plan 
A key plan shall be included on the design drawings for subdivisions or if the 
location of the works cannot be easily deduced from the detailed design plans. 
A key plan, when required, shall be on the right side of the design drawings and 
shall include the following information: 
(a) Plan of adjacent streets and existing lots with streets named and legal 
descriptions of subject and adjacent lots given; 
(b) Civic address with the subject property being subdivided shown shaded; 
(c) North arrow. 
If the subdivision is to be developed in stages, each proposed stage shall be 
clearly outlined and order of development indicated. 
If a key plan is not required, the house number of existing houses shall be 
shown on the detailed design plan. 
2.8 
Rights of Way and Easements 
All existing rights-of-way or easements must be verified with supporting 
documents and shall be shown lightly shaded on the design drawing. 
Registration numbers and boundaries of rights-of-way or easement shall be 
shown lightly shaded. 
All proposed rights-of-way for new services are to be shown as a dashed line. 
These shall be tied to the iron pin in each lot, together with their width, permitted 
use, and the note “acquire” or “proposed”. 
2.9 
Subdivisions 
The potential building envelope of each lot is to be indicated. 
 
2.10 Roads, Curbs and Sidewalk 
Both plan and profile shall be tied to an iron pin or monument, preferable near 
or at 0+0 chainage. If the chainage exceeds 150 m, a second tie shall be 
shown. 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DRAWING STANDAND 
PAGE 5 OF 10 
CONSOLIDATED TO MAY 2025 
 
 
Show all iron pins adjacent to the works and the existing ground elevation at 
each pin or proposed pins. 
 
Show the road width, curb and sidewalk offsets and materials used measured 
from the property line. A typical cross-section shall also be shown on a 
separate drawing sheet. 
 
Show actual location and dimensions of sidewalk drops, on a detail plan. 
 
Road profiles shall show centerline and gutter(s) or edge(s) of pavement 
elevation at 10 m intervals. 
 
A detail plan for cul-de-sacs, shall show gutter elevations at all BC’s and EC’s 
and at intervals of no more than 5 metres along the gutter line. A profile along 
the gutter line shall show how it is graded. 
 
A typical cross sectional view of road construction shall be included where 
circumstances require special consideration. In all cases the standard drawing 
section shall be referenced on the drawing. 
 
Cross-sections are required for drawings depicting new or rehabilitated roads 
and sidewalks. 
 
For new road and sidewalk features, a 10 m interval cross section is required. 
 
For road works, cross-section elevations must span the full width of the road 
allowance. Cross-section elevations must include property lines, back of 
sidewalk, front of sidewalk, top of curb, gutter, ¼ pt of road width or edges of 
existing road and centerline of road. It must also illustrate changes and 
elevations of each break in the cross-section. 
 
The new road works must be shown on each cross-section with bold lines that 
emphasize the finished surface. Elevations of the new road must be shown. 
Road measurements from centreline of the road allowance must also be 
illustrated. 
 
The profile shall be shown at the true centreline length and provided in as close 
relationship as possible to the plan. 
 
Locate catch basins by chainage to the centre back. 
 
Existing and proposed driveway locations shall be shown, as well as a profile of 
each driveway from the road centreline to the end of the driveway within the 
property. 
 
Chainage of the BC and EC of horizontal curves shall be shown together with 
the internal angle, tangent length, arc and centreline radius. A table showing 
curve and curve return data is to be shown on the road drawings as shown in a 
sample below in Table 1. 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DRAWING STANDAND 
PAGE 6 OF 10 
CONSOLIDATED TO MAY 2025 
 
 
CURVE DATA TABLE 1 (example) 
Curve 
A 
B 
C 
D 
E 
Radius 
30.000m 
10.000m 
110.000m 
6.000m 
6.000 
Angle 
57°49’33” 
8°21’00” 
18°40’59” 
71°37’15” 
24°41’54” 
Arc 
30.278m 
15.595m 
35.869m 
7.500m 
2.586m 
Tangent 
16.523m 
9.927m 
18.095m 
4.329m 
1.314m 
B.C. 
0+00.00 
0+30.280 
0+50.380 
0+86.250 
0+93.746 
E.C. 
0+30.280 
0+45.870 
0+86.250 
0+93.746 
0+96.260 
 
 
The centerline percent grade to two decimal places shall be shown on the 
profile together with the following information on vertical curves: 
 
The chainage and elevations of BVC, EVC, and VPI; 
 
The external value, ‘e’; 
 
The ‘K’ value; 
 
The length of the vertical curve; 
 
The elevation and chainage of low points for sag curves. 
 
The gutter(s) percent grade to two decimal places shall be shown on the profile 
together with the following: 
• 
Proposed gutter(s) elevations at 10m change stations. 
• 
Chainage and elevation of proposed gutter(s) BC, EC, BVC, EVC and CB’s. 
 
Horizontal curve radii to be designed to the nearest 1.0m 
 
Pavement tapers are to be dimensioned to legal with length of taper and the 
offset to existing pavement. 
2.11 Sewer and Drains 
The following information shall be shown on the profile: 
(a) Size, type, class of pipe. 
(b) Percent grades to two decimal places. 
(c) Invert elevations at both inlet and outlet of manholes. 
(d) Details of vertical curves. 
(e) Existing utilities. 
(f) The following information shall be shown on the plan: 
(g) Details of horizontal curves; 
(h) Pipe offsets from property line; 
(i) Chainage or measurement from the downstream manhole of service 
connections. Offset to the nearest property corner of the end of the 
service connection. 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DRAWING STANDAND 
PAGE 7 OF 10 
CONSOLIDATED TO MAY 2025 
 
(j) Invert elevation at the property line and the grade of service connections 
from the upper end to the drop to the main, if other than two percent. 
 
The following additional information shall also be shown on the appropriate part 
of the drawing: 
(a) Sanitary sewer manholes and cleanouts shall be identified by a capital “S” 
followed by a unique letter. 
(b) Storm drain manholes, cleanouts and catchbasins shall be identified by a 
capital “D” followed by a unique number. 
(c) Structural detail of all manholes not covered by Municipal Standard 
Drawings or MMCD. 
 
2.12 Water 
 
 
 
 
 
Drawings shall have the Island Health permit number and approval from CRD. 
Drawings shall indicate whether a water main passes over or under other 
underground services which it is crossing. 
The pipe size and type shall be shown on the profile. 
 
2.13 Street Lighting and Signal Design 
Plot existing and proposed lamp and signal standards and show the 
measurement between them and their measurement from the proposed curb 
face. 
 
Signal and light pole design including design details and elevations including 
bases. 
 
Indicate wattage of luminaries to meet standard lighting levels. 
 
Plot and identify all existing and proposed street lighting and traffic signal 
operating devices such as: 
(a) Underground conduits; 
(b) Signal loops (wires); 
(c) Traffic counters and counting loops; 
(d) Traffic control boxes; 
(e) Pull boxes; 
(f) And other related street lighting infrastructure. 
 
2.14 Other Utilities 
Existing and design detail information for utilities such as Hydro, 
Telecommunications and Gas shall be obtained from the appropriate utility 
company. 
 
The following information shall be shown on the design drawings: 
(a) Existing utilities. 
(b) Utility offset from property line and/or iron pin. 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DRAWING STANDAND 
PAGE 8 OF 10 
CONSOLIDATED TO MAY 2025 
 
(c) Lot connections and other appurtenances offset to the nearest property 
line. 
(d) Proposed poles shall be dimensioned from the pole’s road face to 
property line and/or pin. 
(e) Indicate how utility vaults will drain to the storm drain system and who will 
install the drain connection. 
(f) Underground Hydro, telecommunications and gas infrastructure such as 
duct bank and vault outlines. 
 
 
Section 3.0 - Record Drawings 
3.1 
Submission Sets 
Within four weeks of completion of all services installed by the Owner, the 
Consulting Engineer shall deliver Record Drawings, representing what was 
constructed, to the Town of View Royal. These drawings shall include the 
following statement signed, sealed and dated by the Consulting Engineer: 
“I [name and professional designation], certify that the following services (name 
them) were inspected during construction and to the best of my knowledge, 
were installed in accordance with the Town of View Royal Specifications and as 
shown on this drawing. I further certify that the locations of all surface 
appurtenances of the various utility companies are shown correctly on this 
Record Drawing." 
The first submission of as-constructed record drawings shall consist of one 
paper print of the approved design drawing with changes or corrections 
highlighted in colour. 
(a) Sanitary Sewer – Red 
(b) Storm Drains – Green 
(c) Water – Dark blue 
(d) Gas – Brown 
(e) Curb, sidewalk, road – Orange 
(f) Power and Telecommunications– Purple 
(g) Lighting – Pale Blue 
After approval of the paper print submission of the Record Drawing, the original 
design revised as required to show services as constructed, shall be submitted, 
using the latest version of AutoCAD. Record drawings shall use the Town’s 
current drawing standards and layer conventions. 
3.2 
Dimensioning 
The as-constructed drawings shall clearly show the location of all construction, 
improvement and services as installed, using offsets from survey pins. The 
locations will be shown either by check-marking any original dimension on the 
drawing (if they are correct) or by showing the revised dimension beside the 
original dimension. 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
DRAWING STANDAND 
PAGE 9 OF 10 
CONSOLIDATED TO MAY 2025 
 
3.3 
Tolerances 
All horizontal dimensions shall be to the nearest 100mm. All vertical elevations 
shall be to the nearest 5mm, except that ground elevations and service 
connection inverts at property line shall be to the nearest 30mm; 
Road horizontal locations shall be to the nearest 30mm; 
Road vertical locations shall be to the nearest 15mm; 
Minimum Basement Floor Elevation (MBFE) shall be shown to the nearest 
25mm. 
3.4 
Roads Curb and Sidewalk 
Locate the curbs, sidewalks and pavement. 
 
3.5 
Sewer and Drains 
Show the location and extent of rock cuts and hardpan requiring blasting. 
Show the invert elevation of inlets and outlet in manholes. 
Show and label manholes, cleanouts and other appurtenances. 
Locate catch basin leads at the main by measurement from the centre of the 
downstream manhole. 
Locate service connections at property line showing distance from the nearest 
iron pin or property line and at the main by chainage from the centre of the 
downstream manhole. 
Show ground and invert elevations of sewer and drain service connections at 
the property line or edge of right-of-way. 
 
3.6 
Water 
 
 
 
 
 
 
Show domestic water service connections at property line showing distance 
from the nearest iron pin or property line 
Show the location and extent of rock cuts and hardpan requiring blasting. 
Show the profile for mains. 
Tie the locations of fire hydrants to a main valve and to iron pins. 
 
3.7 
Street Lighting and Traffic Signals 
Show the location and extent of rock cuts and hardpan requiring blasting. 
Show all poles and light standards including details and elevations. 
Show all street lighting and traffic signal operating devices such as: 
(a) Underground conduits; 
(b) Signal loops (wires); 
(c) Traffic counters and counting loops; 
(d) Traffic control boxes; 

TOWN OF VIEW ROYAL 
SUPPLEMENTARY 
10 
DRAWING STANDAND 
PAGE 10 OF 
CONSOLIDATED TO MAY 2025 
 
 
 
(e) Pull boxes; 
(f) And other related street lighting and signaling infrastructure. 
3.8 
Other Utilities 
Show service connections 
Show the location, number and size of conduits and mains. 
Show all surface appurtenances and infrastructure 