Architectural drawings and elevations for the proposed carport structure at 3560 Highland Road.

1 CALL TO ORDER- Mayor Tobias called the meeting to order at 7:00 p.m.
Sheet No: A900Building Height: 3.3m (10'-10 5/8")Finish: Standing seam metal roof to match house

Accessory Building - Van Mol / Freeman Residence

Location: Highland Road Sheet No.: A900 Date: 2024-09-03 Drawn by: Amanda Hoy Scale: As noted

Issue History

no. issue description date
Z Accessory Building 2025-01-06
Y IFC revised 2024-09-26
X IFC 2024-09-12
W for internal review 2024-09-09
V BP REV3 2024-09-03
U BP REV2 2024-08-12
T BP REV1 2024-07-16

General Notes

  • All rights of way boundaries, setbacks and property lines to be confirmed by B.C.L.S. prior to construction.
  • Contractor to verify all dimensions and confirm same on site.
  • Any inconsistencies or unforeseen conditions to be reviewed by the architect prior to proceeding with construction.
  • All clearances, methods and materials to be compliant to all applicable building codes and municipal bylaws.
  • All dimensions are in feet and inches unless otherwise noted.
  • Do not scale drawings.
  • All dimensions are measured to face of structure, unless noted otherwise.
  • Smoke alarms to conform with CAN/ULC - S531, refer to BCBC 2024.

Legend

  • Contour Line
  • Site Grades
  • Fan
  • Smoke Detector
  • Wall, Floor and Roof Tag
  • Door Tag
  • Window Tag
  • Exterior Finish Symbol
  • Grid Line
  • Building Section
  • Floor Elevation
  • Centerline

1 ACC. FOUNDATION PLAN

Scale: 1/4" = 1'-0" Plan view showing the foundation layout for a 24'-0" x 24'-0" structure. Key components include:

  • Pad footing (see structural for sizing).
  • Concrete pier with timber post above.
  • 12'-0" spacing between piers on both axes.

2 ACC. MAIN FLOOR

Scale: 1/4" = 1'-0" Plan view showing the carport layout:

  • Floor Material: Gravel.
  • Finished Grade: 51.95m.
  • Dimensions: 24'-0" x 24'-0" structure.
  • Overhangs: 2'-6" on all four sides.
  • Notes: Timber post on pier; line of overhang above (1'-2" offset shown at post).

3 ACC. ROOF PLAN

Scale: 1/4" = 1'-0" Plan view showing the roof structure:

  • Slope: Labeled "SLOPE DOWN" toward the north.
  • Components: Continuous gutter, post below.
  • Overhangs: 2'-6" on all sides.

4 WEST ELEVATION (east sim.)

Scale: 1/4" = 1'-0"

  • Acc. Building Height: 55.3m.
  • Finished Grade: 52.0m.
  • Total Height: 10'-10 5/8" (3.3m) [4.5m max permitted].
  • Roof Slope: 0.6 : 12.
  • Notes: CARPORT open to beyond; retaining method for finished grade t.b.d.
  • Existing Grade Markers: 54.0m and 52.8m.

5 SOUTH ELEVATION

Scale: 1/4" = 1'-0" Elevation showing the structure open to beyond with 2'-6" roof overhangs and existing grade markers at 52.8m.

6 NORTH ELEVATION

Scale: 1/4" = 1'-0" Elevation showing the structure open to beyond, featuring:

  • Continuous gutter and RWL (Rainwater Leaders).
  • Existing grade marker at 54.0m.
  • 2'-6" roof overhangs.

7 SECTION

Scale: 1/4" = 1'-0" Vertical cross-section showing interior clearances and heights:

  • Post Heights: 7'-6" and 8'-8 1/2".
  • Interior Clearance: 8'-1 1/4".
  • Foundation Depth: 1'-4".
  • Note: CARPORT open to beyond.

8 SECTION

Scale: 1/4" = 1'-0" Vertical cross-section showing the carport structure open to beyond.

9 DETAIL - FOOTING

Scale: 1/2" = 1'-0" Detailed section of the foundation:

  • Timber post (see structural).
  • Concrete pier (see structural).
  • Footing: 5'-0" wide x 1'-4" thick (see structural).
  • Grade: 8" minimum clearance from top of pier.

10 DETAIL - FASCIA

Scale: 1" = 1'-0" Detailed section of the roof edge and fascia:

  • Standing seam metal roof (R1).
  • Underlay and 5/8" T&G plywood sheathing.
  • Drip edge flashing.
  • 2x10 P.T. fascia.
  • 2x8 rafter and beam (see structural).
  • Post (see structural).

ROOF ASSEMBLY (R1)

  • Standing Seam Metal Roof (to match house)
  • Underlay
  • 5/8" T&G Plywood Sheathing
  • 2x8 Rafters @ 16" o.c.