Regulatory text for the Attached Residential (Medium Density) zone, specifying permitted uses and siting requirements.

2. APPROVAL OF AGENDA
Max density: 50 units per gross hectareMax height: 7.5 m and 2.5 storeys

Zone Table

Attached Residential (Medium Density): RM-1

RM-1 Zone Table showing Permitted Uses, Conditions of Use, Siting, Density, Floor Space Ratio, and Size of Buildings and Structures
RM-1 Zone Table showing Permitted Uses, Conditions of Use, Siting, Density, Floor Space Ratio, and Size of Buildings and Structures

Permitted Uses

  • Residential Single Family, subject to the regulations of the R-1 zone
  • Residential Attached
  • Home Occupation

Conditions of Use

Dwelling units located wholly or in part above another dwelling unit shall be permitted provided that each unit has a separate direct access to the outside.

Siting of Buildings and Structures

Feature Minimum Requirement Dimension
Front Yard minimum of 7.5 m
Rear Yard minimum of 10.0 m
Side minimum of 7.5 m (Amendment Bylaw, 1994, No. 223)
Side Yard Flanking minimum of 6.0 m
Common Access Road minimum of 7.5 m (Amendment Bylaw, 1996, No. 283)

Density

The maximum density for attached residential use shall be 50 units per gross hectare, (20 units per gross acre), except that where the required parking spaces per unit are provided as enclosed underground parking, the maximum density for attached residential use shall be 100 units per gross hectare (40 units per gross acre).

Floor Space Ratio

Feature Limit Value
Floor Space Ratio maximum of 0.45, except that, where the required parking spaces per unit are provided as enclosed underground parking, the maximum floor space ratio shall be 0.60.

Size of Buildings and Structures

Feature Limit Requirement
Height maximum of 7.5 m and 2.5 storeys (Amendment Bylaw, 2009, No. 752)
Lot Coverage maximum of 35%, except that where the required parking spaces per unit are provided as enclosed underground parking, maximum lot coverage shall be 50%.

Attached Residential (Medium Density): RM-1 cont'd

Continuation of RM-1 Zone Table showing Minimum Finished Floor Areas, Building Separation, Lot Size, and Amenity Area
Continuation of RM-1 Zone Table showing Minimum Finished Floor Areas, Building Separation, Lot Size, and Amenity Area

Minimum finished floor areas shall be:

  • 40 m² (430.6 sq.ft.) for bachelor or seniors' dwelling units
  • 80 m² (861.1 sq.ft.) for 1-bedroom units
  • 90 m² (968.8 sq.ft.) for 2-bedroom units
  • 100 m² (1076.4 sq.ft.) for units with 3 or more bedrooms

Building Separation

Where one wall faces another wall of the same building or another building on the same lot, buildings and structures shall be sited to provide a continuous unencumbered 90 horizontal arc, from the centre of a window in:

Window Location Requirement Distance
Living rooms minimum radius of 15 m
Bedrooms, kitchens and other habitable rooms minimum radius of 12 m
Non-habitable rooms minimum radius of 6 m

Lot Size

Feature Requirement Measurement
Lot Area minimum of 1500 m²
Except that, where sanitary sewer services are not being provided, the minimum lot area shall be 8.0 hectares (19.8 acres) (Amendment Bylaw 2003, No. 505)
Lot Width minimum of 18 m

Amenity Area

Children's play area shall be provided as follows:

  • For each 2-bedroom unit: minimum of 10 m²
  • For each 3-bedroom unit: minimum of 20 m²
  • Any individual play area: minimum of 50 m²

No children's play area shall be located adjacent to accessible parking area or manoeuvring aisle. (Amendment Bylaw, 1994, No. 196)

Page 95–96
Extracted from: 2014 05 13 Committee of the Whole Agenda