6.0 RURAL / AGRICULTURAL ZONES Regulations

December 9, 2014Pages 71–761 section

Extracts from the zoning bylaw detailing lot size, coverage, height, and setbacks for A-1, A-2, and A-3 rural zones.

2. APPROVAL OF AGENDA
Minimum lot size for A-1 Rural: 4 ha to 8 ha depending on sewer service

6.0 RURAL / AGRICULTURAL ZONES

6.1 A-1: Rural

6.1.1 Principal Uses

a) Agriculture b) Residential, Detached c) Riding Stable

6.1.2 Accessory Uses

a) Home Occupation b) Secondary Suite c) Kennel

6.1.3 Lot Size, Lot Coverage, Building Height and Setbacks

A-1: Rural
Lot Size
Lot Size for Kennel Use, minimum 2 ha
Lot Size with Sanitary Sewer Service, minimum 4 ha
Lot Size without Sanitary Sewer Service, minimum 8 ha
Lot Width, minimum 10% of the perimeter
Lot Density
Residential, Detached dwellings per lot, maximum 1
Secondary Suites per lot, maximum 1
Principal Building Floor Area, maximum 372m²
Accessory Building Floor Area, maximum 600m²
Lot Coverage, maximum 20%
Impermeable Surface Coverage, maximum 40%
Building Size
Building Height, maximum 9m
Building Height for agriculture use, maximum 12m
Accessory Building Height, maximum 4.5m
Siting of Principal Buildings and Other Structures
Front Lot Line Setback, minimum 7.5m
Rear Lot Line Setback, minimum 7.5m
Side Lot Line Setback, minimum 7.5m
Flanking Lot Line Setback, minimum 7.5m
Siting of Accessory Buildings and Other Structures
Front Lot Line Setback, minimum 30m
Rear Lot Line Setback, minimum 15m
Side Lot Line Setback, minimum 15m
Flanking Lot Line Setback, minimum 15m

6.2 A-2: Pike Lake Rural Residential

6.2.1 Principal Uses

a) Agriculture b) Residential, Detached c) Riding Stable

6.2.2 Accessory Uses

a) Home Occupation b) One additional detached residential dwelling for the purpose of housing agriculture employees or caretakers c) Secondary Suite d) Kennel

6.2.3 Conditions of Use

a) For the purpose of 6.2.2b), an additional Residential, Detached dwelling is permitted as an accessory use only on a lot classified as a farm pursuant to the Assessment Act, where such lot is 4 ha or more in area.

6.2.4 Lot Size, Lot Coverage, Building Height and Setbacks

A-2: Pike Lake Rural Residential
Lot Size
Lot Size, minimum 8 ha
Lot Size for Kennel Use, minimum 2 ha
Lot Width, minimum 10% of the perimeter
Lot Density
Residential, Detached dwellings per lot, maximum 1
Secondary Suites per lot, maximum 1
Principal Building Floor Area, maximum 372m²
Accessory Building Floor Area (all buildings), maximum 600m²
Lot Coverage, maximum 20%
Impermeable Surface Coverage, maximum 40%
Building Size
Building Height, maximum 9m
Building Width, minimum 6m
Building Height for agriculture use, maximum 12m
Accessory Building Height, maximum 4.5m
Siting of Principal Buildings and Other Structures
Front Lot Line Setback, minimum 7.5m
Rear Lot Line Setback, minimum 7.5m
Side Lot Line Setback, minimum 7.5m
Flanking Lot Line Setback, minimum 7.5m
Siting of Accessory Buildings and Other Structures
Front Lot Line Setback, minimum 30m
Rear Lot Line Setback, minimum 15m
Side Lot Line Setback, minimum 15m
Flanking Lot Line Setback, minimum 15m

6.3 A-3: Rural Residential

6.3.1 Principal Uses

a) Agriculture b) Residential, Detached c) Riding Stable

6.3.2 Accessory Uses

a) Home Occupation b) Secondary Suite

6.3.3 Lot Size, Lot Coverage, Building Height and Setbacks

A-3: Rural Residential
Lot Size
Lot Size with Sanitary Sewer Service, minimum 0.5ha
Lot Size without Sanitary Sewer Service, minimum 8 ha
Lot Width, minimum 10% of the perimeter
Lot Density
Residential, Detached dwellings per lot, maximum 1
Secondary Suites per lot, maximum 1 (min. lot size of 600m²)
Accessory Buildings Per Lot, maximum Unlimited (limited by Floor Area)
Principal Building Floor Area, maximum 372m²
Accessory Building Floor Area (all buildings), maximum 600m²
Lot Coverage, maximum 20%
Impermeable Surface Coverage, maximum 40%
Building Size
Building Height, maximum 9m
Building Width, minimum 6m
Building Height for agriculture use, maximum 12m
Accessory Building Height, maximum 4.5m
Siting of Principal Buildings and Other Structures
Front Lot Line Setback, minimum 7.5m
Rear Lot Line Setback, minimum 7.5m
Side Lot Line Setback, minimum 7.5m
Flanking Lot Line Setback, minimum 7.5m
Siting of Accessory Buildings and Other Structures
Front Lot Line Setback, minimum 30m
Rear Lot Line Setback, minimum 15m
Side Lot Line Setback, minimum 15m
Flanking Lot Line Setback, minimum 15m