This site is in beta — data may be incomplete and features are still being added.
Committee of the Whole/Documents/Proposed RM-3 Zone: Mixed Residential Specifications
Appendix

Proposed RM-3 Zone: Mixed Residential Specifications

May 12, 2015Pages 198–1991 section

Technical table detailing permitted uses, building sizes, and setbacks for the proposed new zone.

9.2.3 e Rezoning - 280 Island Highway
Max building height: 13.5mLot coverage maximum: 60%Minimum lot size: 1500 m²

7.4 RM-3 Zone: Mixed Residential

7.4.1 Principal Uses

a) Residential, Apartment b) Residential, Rowhouse c) Residential, Townhouse d) Community Care Facility

7.4.2 Accessory Uses

a) Home Occupation

7.4.3 Conditions of Use

a) Where a Residential Rowhouse is provided within either a fee simple or strata subdivision, the side lot line setback which constitutes the party wall between two units may be reduced to 0.0m.

7.4.4 Lot Size, Lot Coverage, Building Height and Setbacks

RM-3: Mixed Residential
Lot Size
Lot Size, minimum 1500m²
Lot Width, minimum 40m
Lot Density
Floor Space Ratio, Base Density 1.1 1.5
Floor Space Ratio with provision of 80% underground parking Base Density + 0.1
Floor Space Ratio Bonus Density provision of 75% green roof Base Density + 0.1
Lot Coverage, maximum 60%
Impermeable Surface Coverage, maximum 80%
Building Size
Building Height, maximum 13.5
Building Width, minimum 6m
Accessory Building Height, maximum 4.5m
Siting of Principal Buildings and Other Structures
Front Lot Line Setback, minimum 7.5m
Rear Lot Line Setback, minimum 7.0m
Side Lot Line Setback, minimum 4.0m
Flanking Lot Line Setback, minimum 4.0m
Siting of Accessory Buildings and Other Structures
All lot lines, minimum 1.2m
Page 198–199

Document Images

(2)
Document image
Document image
Extracted from: 2015 05 12 Committee of the Whole Agenda