Appendix
Stantec Site Servicing and Access Conceptual Design
May 11, 2021Page 1941 section
A conceptual design map for site servicing and access at 221 Atkins Road, prepared by Stantec Consulting Ltd.
221 Atkins RoadDrawing No. C101Project No. 111720086
SITE SERVICING AND ACCESS CONCEPTUAL DESIGN
Client/Project: DAVID McALLISTER CIVIL SUPPORT SERVICES 221 ATKINS ROAD, VIEW ROYAL BC
Project Details:
- Project No.: 111720086
- Drawing No.: C101
- Scale: 1:200
- Date: 20.12.21
GENERAL NOTES:
- ALL CONSTRUCTION & MATERIALS TO BE IN ACCORDANCE WITH THESE DRAWINGS AND APPLICABLE MMCD AND TOWN OF VIEW ROYAL STANDARD SPECIFICATIONS AND DRAWINGS.
- PERMIT TO CONSTRUCT WORKS ON MUNICIPAL ROAD ALLOWANCE AND/OR MUNICIPAL RIGHT-OF-WAY MUST BE OBTAINED FROM THE TOWN OF VIEW ROYAL ENGINEERING DEPARTMENT BEFORE WORKS COMMENCE.
- A PERMIT TO CONSTRUCT WORKS UNDER OR ADJACENT TO BOULEVARD OR BY-LAW PROTECTED TREES MUST BE OBTAINED FROM TOWN OF VIEW ROYAL PARKS DEPARTMENT BEFORE WORKS COMMENCE.
- EXISTING SERVICES MUST BE EXPOSED AT CROSSING POINTS BEFORE CONSTRUCTION.
- MAINTAIN VEHICULAR ACCESS TO EXISTING HOUSES IN AREA.
- ALL CONNECTIONS/SERVICES PROVIDED BY MUNICIPAL CREWS WILL BE COMPLETED AT THE APPLICANT'S EXPENSE FOR THE ESTIMATE AMOUNT ON THE APPLICABLE FIXED FEE.
- ALL NEW BC HYDRO, TELUS, SHAW CABLE AND FORTISBC WORKS TO BE UNDERGROUND, AND TO BE INSTALLED BY RESPECTIVE UTILITY COMPANY.
- WATER SERVICE CONNECTIONS TO EXISTING WATER MAIN TO BE MADE BY CRD WATER DEPARTMENT.
- THE CONTRACTOR SHALL REQUEST INSPECTIONS A MINIMUM 24 HOURS PRIOR TO BEING REQUIRED AND ONLY AFTER THEY HAVE SATISFIED THEMSELVES THAT NO DEFICIENCIES EXIST. REINSPECTIONS SHALL BE AT THE CONTRACTOR'S EXPENSE.
- CAUTION: CONTACT BC 1 CALL AT 1-800-474-6886 AT LEAST 48 HOURS IN ADVANCE OF EXCAVATIONS FOR LOCATION OF GAS MAINS AND SERVICES.
- ALL FILL UNDER ROADWAYS & TRAVEL AREAS TO BE COMPACTED TO MINIMUM 95% MODIFIED PROCTOR DENSITY UNLESS NOTED OTHERWISE. PROVIDE COPIES OF TEST RESULTS TO CIVIL ENGINEER FOR REVIEW.
- REFER TO ARBORIST DRAWINGS FOR TREE REMOVAL AND PROTECTION DETAILS.
- REFER TO ENVIRONMENTAL REPORT FOR STREAM PROTECTION DETAILS.
- DRIVEWAYS TO BE PAVED WITH MINIMUM 50mm OF ASPHALT.
CONSTRUCTION NOTES:
- INSTALL WATER METER AND 19mm SERVICE
- 50mm CORPORATION STOP IN PYRAMIDAL STYLE ACCESS BOX.
- REMOVE ROADSIDE BARRIERS AS REQUIRED FOR DRIVEWAY ACCESS.
REVISION HISTORY:
| Revision | Description | By | App'd | Date |
|---|---|---|---|---|
| FOR APPROVAL | Issued | KP | AG | 20.12.21 |
Call Before You Dig: BC 1 CALL: 1-800-474-6886
Disclaimer: PRELIMINARY NOT TO BE USED FOR CONSTRUCTION
Page 194
Extracted from: 2021 05 11 Committee of the Whole Agenda - Agenda - Pdf