Committee of the Whole/Documents/As Built Site Plan - SK-18 R1
Appendix

As Built Site Plan - SK-18 R1

May 11, 2021Page 2131 section

An as-built site plan drawing for Thetis Lake Apartments on West Park Lane, showing parking layout and retaining wall locations.

1938 West Park LaneDate: 02/11/2021Drawing No. SK-18

THETIS LAKE APARTMENTS - AS BUILT SITE PLAN

Project Information

  • Project Name: THETIS LAKE APARTMENTS
  • Project Number: -
  • Address: 1938 WEST PARK LANE, VIEW ROYAL, BC
  • Drawing Title: AS BUILT SITE PLAN
  • Drawn by: PG
  • Checked by: BC
  • Date: 01/10/2020
  • Scale: 1 : 250
  • Drawing #: SK-18
  • Revision #: R1
  • Project Status: ISSUED FOR INSTRUCTION
  • Construction Status: ISSUED FOR CONSTRUCTION

Revision Schedule

No. Description Revision Date
B ISSUED FOR DEV PERMIT 02/19/2019
C RE ISSUED FOR DEV PERMIT 04/12/2019
- NEW PERSPECTIVE SHEET A1.8 04/22/2019
- REVISED SIDING-FLOORS 5 & 6 BY MAIN ENTRIES 05/03/2019
- NEW SECTION SHEET A1.8 - PERSPECTIVE REVISED A1.9 -
E ISSUED FOR COORDINATION 05/15/2019
- ADJUST PL TO SURVEY 06/18/2019
F ISSUED FOR CRD REVIEW 07/08/2019
G ISSUED FOR FOUNDATION PERMIT 08/02/2019
H ISSUED FOR BLDG PERMIT 08/09/2019
0 ISSUED FOR CONSTRUCTION 01/10/2020
SK-18 R1 AS IS SITE PLAN 02/11/2021

Trade Contractor Instructions

TRADE CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND REPORT ANY DISCREPANCIES OR INCONSISTENCIES TO SEYMOUR PACIFIC DEVELOPMENTS LTD., WITHOUT DELAY, FOR CLARIFICATION AND/OR CONFIRMATION. DO NOT SCALE DRAWINGS. DESIGNS REPRESENTED AND DRAWINGS USED AS INSTRUMENTS OF SERVICE SHALL REMAIN THE COPYRIGHT AND PROPERTY OF SEYMOUR PACIFIC DEVELOPMENTS LTD. ANY REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN THAT AUTHORIZED BY SEYMOUR PACIFIC DEVELOPMENTS LTD. IS PROHIBITED.

CONTRACTORS SHALL REMAIN FAMILIAR WITH, SHALL REFER TO, AND SHALL PERFORM IN ACCORDANCE WITH LOCAL LAWS, REGULATIONS AND BUILDING CODES. CONTRACTORS SHALL MAINTAIN GOOD INDUSTRY BUILDING AND SAFETY PRACTICES CONSISTENT WITH THE CONTRACT INTENT AND THE REQUIREMENTS OF JURISDICTIONAL AUTHORITIES.

ADDITIONAL CLAIMS AND COSTS RELATED TO NON-MATERIAL CHANGES WILL NOT BE ACCEPTED BY SEYMOUR PACIFIC DEVELOPMENTS LTD. NON-MATERIAL CHANGES ARE DEEMED TO BE PLAN CHANGES OR SPECIFICATION ADJUSTMENTS THAT DO NOT SUBSTANTIALLY AFFECT THE VALUE, TIME, COST AND QUALITY OF CONSTRUCTION.

CONTRACTORS SHALL MAKE EVERY REASONABLE EFFORT TO MAINTAIN SCHEDULE TARGETS AND PROVIDE GOOD EFFICIENCY, PROGRESS, WORKMANSHIP AND QUALITY TOWARD DEFICIENCY-FREE RESULTS.

Site Plan Details

The site plan provides a layout for the development with the following key annotations:

  • Dimensions: Marked as "DIMENSIONS ARE APROXIMATE".
  • Walls:
    • LOCK BLOCK WALLS (specified heights include 7' - 3" / 2.210m, 1.3M HIGH, and .7M HIGH).
    • ALLEN BLOCK WALLS.
  • Utilities and Electrical:
    • CONDUIT LINE FOR 16 EV STALLS.
    • 18 designated "EV Stall" parking spaces.
    • BC HYDRO, SHAW, TELUS BOXES - NO PLANTING.
  • Landscaping and Site Features:
    • NO PLANTING ZONE, ROCK MESH.
    • Various distance markers (e.g., 111' - 2 1/4", 78' - 9", 74' - 7", 22' - 7 1/4").
    • Building footprint and parking stalls.