Handwritten notes comparing the project's projected sewage flow against the municipal master plan assumptions.

Assumed FSR of 1.5Proposed flow approximately 0.756 L/s more than model
Page 788

298 Island.

Compare to Sewer Master Plan.

Given

  • Site area = 1,853 m².
  • Section 4.3 indicates mixed use properties used a FSR of 1.2 – 1.5
    • assume 298 Island has FSR of 1.5 in sewer model.

Assumptions

  • Proposed sewage is proportional to FSR/gross area.

Calculations.

  • Proposed Gross area = 5,559 m².
  • Master sewer plan = 1.5 x 1,853 = 2,779.5 m².
  • $\therefore \frac{5,559}{2,779.5} = 2.$

Master Sewer Plan should have assumed approximately 1/2 the sewage flow based on floor area.

$\therefore$ approximately 0.756 L/s more flow (1/2 PWWF)