Appendix
Attachment 4: Zoning Bylaw Excerpt RM-3 Zone
February 12, 2019Pages 85–861 section
Bylaw text defining the regulations for the Mixed Residential (RM-3) zone.
Max Floor Space Ratio: 1.5 (or 1.6 with underground parking)Max Lot Coverage: 60%
7.4. RM-3 Zone: Mixed Residential
7.4.1. Principal Uses
a) Residential, Apartment b) Residential, Rowhouse c) Residential, Townhouse d) Community Care Facility
7.4.2. Accessory Uses
a) Home Occupation
7.4.3. Conditions of Use
a) Where a Residential Rowhouse is provided within either a fee simple or strata subdivision, the side lot line setback which constitutes the party wall between two units may be reduced to 0.0m.
7.4.4. Lot Size, Lot Coverage, Building Height and Setbacks
| RM-3: Mixed Residential | |
|---|---|
| Lot Size | |
| Lot Size, minimum | 1500m² |
| Lot Width, minimum | 40m |
| Lot Density | |
| Floor Space Ratio, Base Density | 1.5 |
| Floor Space Ratio with provision of 80% underground parking | Base Density + 0.1 |
| Lot Coverage, maximum | 60% |
| Impermeable Surface Coverage, maximum | 80% |
| Building Size | |
| Building Height, maximum | 13.5 |
| Building Width, minimum | 6m |
| Accessory Building Height, maximum | 4.5m |
| Siting of Principal Buildings and Other Structures | |
| Front Lot Line Setback, minimum | 7.5m |
| Rear Lot Line Setback, minimum | 7.0m |
| Side Lot Line Setback, minimum | 4.0m |
| Flanking Lot Line Setback, minimum | 4.0m |
| Siting of Accessory Buildings and Other Structures | |
| All lot lines, minimum | 1.2m |
Amendment Bylaw No. 925, 2015
Page 85–86