This site is in beta — data may be incomplete and features are still being added.
Council Meeting/Documents/A100 LEVEL P1 PLAN
Appendix

A100 LEVEL P1 PLAN

September 6, 2022Page 461 section

Architectural floor plan for the underground parking level P1.

1 CALL TO ORDER
92 parking stalls82 bike lockers

PORTAGE PARK RESIDENCES

167, 169 & 171 Island Highway, View Royal, BC

Architect: UWA Urban West Architecture

  • Vancouver: 102-1688 West 1st Ave, Vancouver BC V6J 1G1 | T 604 603 1332
  • Victoria: 2822 Prior Street, Victoria BC V8T 3Y3 | T 604 603 1332

Level P1 Plan (Drawing A100)

Date: 2022-08-12 Project Number: 2021-01

Garbage Room Table

BIN TYPE NUMBER OF BINS BIN DIMENSIONS (LxDxH) WASTE SERVICE
6 YARD 1 1.83m x 1.68m x 1.52m GARBAGE
3 YARD 1 1.83m x 1.07m x 1.22m CARDBOARD
360 L 4 0.64m x 0.88m x 1.13m MIXED CONTAINERS
360 L 3 0.64m x 0.88m x 1.13m MIXED PAPER
240 L 4 0.62m x 0.70m x 1.09m FOOD
240 L 1 0.62m x 0.70m x 1.09m GLASS

Parking Notes

ALL PARKING AND BIKE STALLS TO BE ENERGIZED

Typ. Parking Stalls

Detailed dimensions for various parking stall types:

  • Parallel Stall: 3000 x 7500
  • Accessible Stall: 4000 x 5500
  • Small Stall @ Wall: 2700 x 4800
  • Small Stall: 2400 x 4800
  • Small Stall @ Wall: 2700 x 4800
  • Regular Stall @ Wall: 2900 x 5500
  • Regular Stall: 2600 x 5500
  • Regular Stall @ Wall: 2900 x 5500

P1 Level Plan Components

The plan includes 92 parking stalls, various ramps, and utility/storage rooms. Key areas and rooms identified:

  • P1.01: Stair #1
  • P1.02: Lobby
  • P1.03: Mech. Room
  • P1.04: Elec. Room
  • P1.05: El. Room
  • P1.06: Bike Room (includes E-Bikes and Cargo Bike Racks)
  • P1.07: Storage Lockers
  • P1.08: Garbage Room
  • P1.9: Water Room
  • Other: Stair #3, Stair #4, Bike Stair Access Ramp, and a dedicated area for 82 lockers.
  • Ramp Specifications:
    • Ramp: 6.0m @ 10%
    • Ramp: 16.7m @ 15%
    • Sloped area: 5% Slope

Revision History

NO. DATE DESCRIPTION
2021 12 03 ISSUED FOR REZONING
2022 04 04 ISSUED FOR DP
2022 08 12 REISSUED FOR DP

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF URBAN WEST ARCHITECTURE INC., AND MAY NOT BE REPRODUCED, COPIED OR LOANED WITHOUT WRITTEN PERMISSION FROM URBAN WEST ARCHITECTURE INC. THIS DRAWING MUST NOT BE SCALED. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS, DATUMS, AND LEVELS PRIOR TO COMMENCEMENT OF WORK. ALL ERRORS AND OMISSIONS MUST BE REPORTED IMMEDIATELY TO URBAN WEST ARCHITECTURE INC. THIS DRAWING IS TO BE USED IN CONJUNCTION WITH ALL OTHER DRAWINGS AND SPECIFICATIONS. THESE DRAWINGS ARE NOT VALID FOR CONSTRUCTION UNLESS REVISION DESCRIPTION INDICATES - ISSUED FOR CONSTRUCTION. ALL WORK TO COMPLY WITH MUNICIPAL STANDARDS.

Page 46

Document Images

(1)
Document image
Extracted from: 2022 09 06 Council Agenda - Agenda - Pdf