This site is in beta — data may be incomplete and features are still being added.
Council Meeting/Documents/A150 UNIT PLANS
Appendix

A150 UNIT PLANS

September 6, 2022Page 491 section

Detailed floor plans for studio and one-bedroom unit types.

1 CALL TO ORDER
Unit type A1Unit types B1 through B4

UWA URBAN WEST ARCHITECTURE

PORTAGE PARK RESIDENCES

167, 169 & 171 ISLAND HIGHWAY, VIEW ROYAL, BC Project No: 2021-01 Sheet Title: UNIT PLANS Sheet No: A150


Unit Plan Summary

TYPE A1 - JR. 1 BEDROOM

  • Quantity: 20 (24%)
  • Total Area: 472 SQ. FT.
  • Rooms: Great Room, Kitchen, Bedroom, Bath, Study, Balcony.
  • Key Notes:
    • Includes variations for Units *14 & *15.
    • Unit *14 variant includes a garbage shaft from parkade (Min. 460 mm x 460 mm).
    • Features a line of 6"x6" GWB plumbing chase and GWB bulkhead above.

TYPE B1 - 1 BEDROOM

  • Quantity: 2 (2%)
  • Total Area: 382 SQ. FT.
  • Rooms: Bedroom, Bath, Kitchen, Roof Deck.
  • Key Notes:
    • Features a line of 6"x6" GWB plumbing chase and GWB bulkhead above.

TYPE B2 - 1 BEDROOM

  • Quantity: 1 (1%)
  • Total Area: 411 SQ. FT.
  • Rooms: Bedroom, Bath, Kitchen, Roof Deck.

TYPE B3 - 1 BEDROOM

  • Quantity: 8 (10%)
  • Total Area: 538 SQ. FT.
  • Rooms: Bedroom, Great Room, Kitchen, Bath, Balcony.
  • Key Notes:
    • Features a line of GWB bulkhead above.
    • Includes an ERV shaft.

TYPE B4 - 1 BEDROOM

  • Quantity: 4 (5%)
  • Total Area: 572 SQ. FT.
  • Rooms: Bedroom, Study, Walk-in Closet (WIC), Bath, Kitchen, Balcony.
  • Key Notes:
    • Features a line of GWB bulkhead above.

Revision History

NO. DATE DESCRIPTION
2022 08 12 RE-ISSUED FOR DP
2022 07 12 RE-ISSUED FOR DP
2022 04 04 ISSUED FOR DP
2021 12 03 ISSUED FOR REZONING

Architect Contact Information

VANCOUVER 102-1688 WEST 1ST AVE VANCOUVER BC V6J 1G1 T 604 603 1332

VICTORIA 2822 PRIOR STREET VICTORIA BC V8T 3Y3 T 604 603 1332


Legal Disclaimer

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF URBAN WEST ARCHITECTURE INC., AND MAY NOT BE REPRODUCED, COPIED OR LOANED WITHOUT WRITTEN PERMISSION FROM URBAN WEST ARCHITECTURE INC. THIS DRAWING MUST NOT BE SCALED. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS, DATUMS, AND LEVELS PRIOR TO COMMENCEMENT OF WORK. ALL ERRORS AND OMISSIONS MUST BE REPORTED IMMEDIATELY TO URBAN WEST ARCHITECTURE INC. THIS DRAWING IS TO BE USED IN CONJUNCTION WITH ALL OTHER DRAWINGS AND SPECIFICATIONS. THESE DRAWINGS ARE NOT VALID FOR CONSTRUCTION UNLESS REVISION DESCRIPTION INDICATES - ISSUED FOR CONSTRUCTION. ALL WORK TO COMPLY WITH MUNICIPAL STANDARDS.

Page 49

Document Images

(1)
Document image
Extracted from: 2022 09 06 Council Agenda - Agenda - Pdf