This site is in beta — data may be incomplete and features are still being added.
Council Meeting/Documents/UNIT PLANS A152
Appendix

UNIT PLANS A152

September 6, 2022Page 511 section

Architectural unit plans for Portage Park Residences featuring 2-bedroom unit types D1, D2, and D3.

1 CALL TO ORDER
167, 169 & 171 Island Highway820 SQ. FT.893 SQ. FT.Date: 2022-08-12

UWA: Urban West Architecture

Vancouver Office 102-1688 West 1st Ave Vancouver BC V6J 1G1 T: 604 603 1332

Victoria Office 2822 Prior Street Victoria BC V8T 3Y3 T: 604 603 1332

Project: Portage Park Residences Address: 167, 169 & 171 Island Highway, View Royal, BC Project No.: 2021-01 Sheet Title: Unit Plans Sheet No.: A152

Revision Schedule

No. Date Description
2022 08 12 RE-ISSUED FOR DP
2022 07 12 RE-ISSUED FOR DP
2022 04 04 ISSUED FOR DP
2021 12 03 ISSUED FOR REZONING

Unit Plan Details

1. TYPE D1 - 2 BEDROOM

  • Quantity: 2 (2%)
  • Scale: 1:50
  • Total Area: 820 SQ. FT.
  • Overall Dimension: 13398 [43'-11 1/2"]
  • Layout Features: Master Bedroom with Ensuite and Walk-In Closet (WIC), Second Bedroom, Main Bathroom, Laundry (W/D), Kitchen, and Roof Deck access.

[Diagram: Floor plan layout for Type D1 - 2 Bedroom unit]

2. TYPE D2 - 2 BEDROOM

  • Quantity: 8 (10%)
  • Scale: 1:50
  • Total Area: 893 SQ. FT.
  • Overall Dimension: 10198 [33'-5 1/2"]
  • Layout Features: Master Bedroom with Ensuite and Walk-In Closet (WIC), Second Bedroom, Main Bathroom, Laundry (W/D), Kitchen, and Balcony.

[Diagram: Floor plan layout for Type D2 - 2 Bedroom unit]

3. TYPE D3 - 2 BEDROOM

  • Quantity: 1 (1%)
  • Scale: 1:50
  • Total Area: 893 SQ. FT.
  • Overall Dimension: 10524 [34'-6 1/4"]
  • Layout Features: Two Bedrooms (one with Ensuite), Main Bathroom, Laundry (W/D), Kitchen, and Balcony.

[Diagram: Floor plan layout for Type D3 - 2 Bedroom unit]


General Notes

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF URBAN WEST ARCHITECTURE INC., AND MAY NOT BE REPRODUCED, COPIED OR LOANED WITHOUT WRITTEN PERMISSION FROM URBAN WEST ARCHITECTURE INC. THIS DRAWING MUST NOT BE SCALED. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS, DATUMS, AND LEVELS PRIOR TO COMMENCEMENT OF WORK. ALL ERRORS AND OMISSIONS MUST BE REPORTED IMMEDIATELY TO URBAN WEST ARCHITECTURE INC. THIS DRAWING IS TO BE USED IN CONJUNCTION WITH ALL OTHER DRAWINGS AND SPECIFICATIONS. THESE DRAWINGS ARE NOT VALID FOR CONSTRUCTION UNLESS REVISION DESCRIPTION INDICATES - ISSUED FOR CONSTRUCTION. ALL WORK TO COMPLY WITH MUNICIPAL STANDARDS.

Page 51

Document Images

(1)
Document image
Extracted from: 2022 09 06 Council Agenda - Agenda - Pdf