This site is in beta — data may be incomplete and features are still being added.
Council Meeting/Documents/SECTIONS (Drawing A320)
Appendix

SECTIONS (Drawing A320)

May 6, 2025Page 541 section

Road section drawings for Unit 11 and back entries for Units 10-12.

8.1 a) Development Permit with Variances Application No. 2024-03 - 294, 296 Eltham Road and 242 Helmcken Road Reconsideration by Mayor as per Section 131, Community Charter
Building 2 roof level (33.87m)Natural grade levels indicatedDrawing A320

SECTIONS

Project: 2130
Client: Jeffrey Sengara
Location: 294 & 296 ELTHAM & 242 HELMCKEN ROAD, VICTORIA, BC.
Architect: ANKENMAN MARCHAND ARCHITECTS
1645 West 5th Avenue, Vancouver, BC V6J 1N5
Tel: (604) 872-2595 | Fax: (604) 872-2505
Email: office@AMArchitects.com

Project Status: DP
Drawing Number: A320
Scale: 1 : 100
Plot Date: 2024-07-11

SUBMISSION

Date (YYYY-MM-DD) Description
2022-06-06 Issued for Rezoning
2023-09-14 Issued for Rezoning
2023-12-06 Issued for Rezoning
2024-07-11 Issued for Development Permit

REVISION

No. Date Description

1 Road Section at Unit 11

Scale: 1 : 100

Building 2 Elevations:

  • BLDG 2 ROOF LEVEL: 111.11' (33.87 m)
  • BLDG 2 LEVEL 3: 102.11' (31.12 m)
  • BLDG 2 LEVEL 2: 93.11' (28.38 m)
  • BLDG 2 GROUND FLOOR: 84.11' (25.64 m)

Floor to Floor Heights:

  • Level 2 to Level 3: 2.74 m
  • Level 3 to Roof: 2.74 m
  • Ground to Level 2: 2.74 m

2 Road Section at Unit 10-12 Back Entries

Scale: 1 : 100

Building 2 Elevations (Left):

  • BLDG 2 ROOF LEVEL: 113.24' (34.52 m)
  • BLDG 2 LEVEL 3: 104.44' (31.77 m)
  • BLDG 2 LEVEL 2: 95.24' (29.03 m)
  • BLDG 2 GROUND FLOOR: 85.43' (26.04 m)
  • Heights: 2.74 m between floors.

Building 4 Elevations (Right):

  • BLDG 4 ROOF LEVEL: 112.20' (34.20 m)
  • BLDG 4 LEVEL 3: 103.20' (31.46 m)
  • BLDG 4 LEVEL 2: 94.20' (28.71 m)
  • BLDG 4 GROUND FLOOR: 84.56' (25.77 m)

Building 4 Floor Heights:

  • Ground to Level 2: 2.94 m
  • Level 2 to Level 3: 2.74 m
  • Level 3 to Roof: 2.74 m

Notes: All Drawings in this set to be read in conjunction with each other. Any errors or discrepancies to be reported to the Architect before commencing work. Contractors are responsible to ensure that all work is executed to the requirements of the appropriate Building Code Authority. © Copyright Ankenman Marchand Architects. All rights reserved.