Appendix
Topographic Plan of Part of Lot 1 (Map)
May 15, 2012Page 571 section
Survey map illustrating the restrictive covenant area and proposed tower site location.
August 2011
Topographic Plan of Part of Lot 1, Section 2, Highland District, Plan 21787
B.C.G.S. 92B.043 Scale 1:250
Legend/Notes
- Distances and elevations are in metres.
- Vertical datum is geodetic datum.
- Grid bearings are derived from GPS observations.
- [Symbol] denotes geodetic monument.
- [Symbol] denotes iron pin.
- [Symbol] denotes wood post.
- [Symbol] denotes concrete post.
- [Circle with Number] denotes tree with associated number.
- [Contour Line] denotes contour line.
- [Dashed line with Arrows] denotes guy wire.
- [Dashed line] denotes overhead wire/power line.
- [Symbol with Number] denotes power pole with associated number.
- [Symbol] denotes hub (marking property corner).
- P.L. denotes property line.
- S.L. denotes section line.
- D.B. denotes district boundary line.
UTM Grid Coordinates
Proposed Centre of Tower Point (A)
- NAD83
- North: 5,370,105.15 m
- East: 465,497.71 m
- Latitude: 48° 29' 33.7" North
- Longitude: 123° 27' 51.4" West
Tree Table
| Tree No. | Species and Details | Diameter at Breast Height (m) |
|---|---|---|
| 1 | F | 0.70 |
| 2 | F | 0.70 |
| 3 | F | 0.50 |
| 4 | F | 0.60 |
| 5 | F | 0.40 |
| 6 | F | 0.70 |
| 7 | F | 0.70 |
| 8 | F | 0.30 |
| 9 | F | 0.30 |
| 10 | F | 0.70 |
| 11 | F | 0.70 |
| 12 | F | 0.50 |
| 13 | F | 138m ± |
| 14 | F | 0.70 |
| 15 | F | 0.70 |
| 16 | F | 0.70 |
| 17 | F | 0.70 |
| 18 | F | 0.70 |
| 19 | F | 0.70 |
| 20 | F | 0.70 |
| 21 | F | 0.70 |
| 22 | F | 0.70 |
| 23 | F | 0.70 |
| 24 | F | 0.70 |
| 25 | F | 0.70 |
| 26 | F | 0.70 |
| 27 | F | 0.70 |
| 28 | F | 0.70 |
| 29 | F | 0.70 |
| 30 | F | 1.10 |
| 31 | F | 1.10 |
| 32 | F | 0.70 |
| 33 | F | 0.60 |
| 34 | F | 0.40 (N) |
| 35 | C | 0.30 (N) |
| 36 | F | 0.40 (N) |
| 37 | F | 0.70 |
| 38 | F | 0.40 |
| 39 | F | 0.50 |
| 40 | F | 0.70 |
| 41 | F | 0.60 |
| 42 | F | 0.60 |
| 43 | F | 0.70 |
| 44 | F | 0.50 |
| 45 | F | 0.50 |
Elevation Table
| Site Point / Number | Elevation |
|---|---|
| Point A (Proposed Centre) | 463.3 |
| Base of Tower | 463.3 |
| Top of Tower | 513.3 |
| Point B | 464.2 |
| Point C | 463.2 |
| Point D | 463.1 |
Project Information
Field work Completed August 2011 J.E. Anderson & Associates Surveying Inc. #1A - 755 Queens Ave. Victoria, B.C. V8T 1M2 (250) 388-4454 File: 36761TP01(02)
Page 57
Extracted from: 2012 05 15 Council Agenda