Council Meeting/Documents/Building Plans - 77 Norquay Rd
Appendix

Building Plans - 77 Norquay Rd

September 4, 2012Pages 81–852 sections

Architectural plans and elevations for the proposed patio addition at 77 Norquay Road.

Designer: Victoria Design GroupPlans dated: 30 July 2012

No. 77 Norquay Road

Legal - Lot B, Section 95, Esquimalt District, Plan VIP87047

Project Information

  • Client: Proposed Covered Patio, Cheryl and Don Laidlaw, Lot B - 77 Norquay Rd. View Royal, BC
  • Design Group: Victoria Design Group
  • Date: 30 JULY 2012
  • Project No.: 6725-P
  • Scale: As Noted
  • Drawn By: JTE/CB

General Notes

  1. Dimensions given take precedence over scale. Contractor to check and confirm all dimensions at Building Designer and Consultants drawings.
  2. Report any discrepancies to Victoria Design Group.
  3. Any discrepancies are to be reported immediately.
  4. Surveyor and/or Contractor to confirm all aspects of siting and elevations.
  5. It is the Contractor's/Owner's ultimate responsibility to ensure that the proposed new or existing structure does not conform to N.B.C. of Canada, B.C.P.B.B. & Building Code & structural engineer may be required for some components of this.
  6. All materials to be of best quality, complying with the applicable CSA, A.S.T.M., C.G.S.B., C.I.S.C. and N.B.C. standards.
  7. All work shall at least comply with the 'National Building Code of Canada'.
  8. The best and customs of best trade practice and these specifications to be executed by skilled tradespersons, well equipped and adequately supervised.
  9. All manufacturing products shall be applied or installed according to the manufacturers' instructions with this specification, no dilution permitted except where specified.

Design Loads

Structural is based on criteria stated in Part 3 and Part 9 of the 1998 B.C. Building Code and other applicable sections. Design live loads as follows:

  • Design main floor load: 40 p.s.f. + strs.
  • Design upper floor load: 30 p.s.f. + strs.
  • Design roof snow load: 34 p.s.f. For heavier snow loading, drawings must be revised.

Demolition

For all renovations and additions, contractor must maintain strength and stability of existing structure, provide and install all shoring and bracing to uphold existing loads during the duration of the work.

Concrete

  1. All concrete used for foundations and floors to be not less than 2500 p.s.i. (15 mpa) @ 28 days unless otherwise noted.
  2. Concrete used for garage floors, carports, exterior walks and steps to be 4500 p.s.i. (32 mpa) air-entrained.
  3. All footings and flgs to be carried down to solid undisturbed bearing.

Framing

  1. All construction and materials to comply with the "approved" current B.C.B.C.
  2. Lumber to be graded in accordance with N.L.G.A. standard grading rules for Canadian lumber, and to be SPF No. 2 or better. All lumber used for exterior use to be pressure treated.
  3. Moisture content of lumber to be a maximum of 19% at time of framing, shelving, curtain rods, cabinets, etc.
  4. All wood to be dried to permit the proper setting out of all work and ensure no accentuating shrinkage.

Mechanical

  1. Provide 2 - 3/4" frost-proof sillcocks in exterior hose bibs at convenient locations.
  2. Ensure that all ducting, openings, doors, windows, etc. do not directly affect any structural items.
  3. Plumbing installation shall comply with current section of A.C.H.B.C., local municipal requirements and BC Plumbing code.
  4. Heating shall comply with ASHRAE & Air Conditioning Code current issue.
  5. All duct sizes, fans and ventilation requirements to be verified prior to install by qualified mechanical contractor.
  6. Fan and ducting requirement for bathrooms: see B.C.B.C. table 9.32.3.8.
  7. Laundry room: 50 cfm intermittent, 2" external static pressure.
  8. Duct size: 5" smooth, 6" flexible. Duct to be non-combustible, and not exceed 15m and 2 elbows.
  9. Mechanical requirement for required cfm and duct size should be verified by M.C.B.C. and manufacturers' specifications.
  10. All wood burning appliances shall comply with CSA B365-M1991.
  11. Bathroom fan requirement: 75 cfm min. (10 cfm max @ 2" External static pressure).
  12. Duct size: 4" smooth, 5" flexible sound rated @ 2 zones.
  13. Fans to have manual control to provide a min. of 4 hours in two 8-hour operating periods per day.
  14. Item 2: See B.C.B.C. table 9.32.3.3.B 50 cfm @ 2" External static pressure. Duct size: 4" smooth, 5" flexible.

Electrical

Refer to general notes for ducting size.

  • [Symbol]: 90 c.f.m. ventilation fan c/w intermittent control.

Site Data

Items Permitted Proposed
Zoning R-1A
Lot Area 650 sq.m. (Min.) 650.00 sq.m. +/-
Lot Coverage 30% (195.00 sq.m.) 30% (195.00 sq.m.)

Setbacks

Description Required Proposed
Front 7.50 m 7.61 m
Rear 7.50 m 6.80 m**
Side 2.14 m 3.05 m
Side 2.14 m 2.90 m
Combined Side Yards 6.10 m 5.95 m*

Floor Area

Description Required Proposed
Main 70 sq.m. (Min.) 109.53 sq.m.
Upper 134.61 sq.m.
Garage 60.57 sq.m.
Total Floor Area 304.71 sq.m.
Garage Allowance 45 sq.m.
Net. Gross Floor Area 40% (260.00 sq.m. Max.) 259.71 sq.m.

Building Height

Description Required Proposed
Building Height 7.50 m. 7.43 m

* Existing Non-Conforming ** Variance Required


Foundation Plan (Exist.)

Foundation Notes

  • Crawlspace: 2" conc. ground seal on 6 mil polyn. v.b. on 6" min. compacted granular fill.
  • 3/2x10 Beam supports.
  • 2" x 10" Floor Joists @ 16" o/c.
  • Proposed Patio Addition: 3 1/2" conc. slab, exposed agg fin on 6" min compact fill.
  • Structural Engineer to review plan (where required) and specify structure as deemed necessary. It is the responsibility of the owner or contractor to verify all engineering requirements with municipal building departments prior to starting work.
  • Truss manufacturer to review plans to verify roof design where eng. roof trusses are shown, and to contact building designer to advise if revisions are necessary.
  • Owner, Gen. or Sub Contractor to verify and thoroughly review all aspects of plan prior to starting work and report any discrepancies immediately to Building Designer.

Main Floor Plan (Exist.)

Main Floor Details

  • Great Room: 8'-8 1/4" Clg.
  • Office: 9'-0 3/4" Clg.
  • Kitchen: 8'-8 1/4" Clg.
  • Dining: 8'-8 1/4" Clg.
  • Storage: 9'-0 3/4" Clg.
  • Garage: 652.0 sq.ft. (60.57 sq.m.)
  • Main Floor Area: 1179.00 sq.ft. (109.53 sq.m.)
  • Proposed Addition: Covered patio with 2" x 6" rafters @ 24" o/c and 4" x 12" K.D. Cedar Beams.

Door Schedule

  • A: 6/0 x 6/8 [1829 x 2032]
  • B: 4/0 x 6/8 [1219 x 2032]
  • C: 3/0 x 6/8 [914 x 2032]
  • D: 4/0 x 6/8 [1219 x 2032]
  • E: 3/0 x 6/8 [914 x 2032]
  • F: 2/10 x 6/8 [864 x 2032]
  • G: 2/8 x 6/8 [813 x 2032]
  • H: 2/6 x 6/8 [762 x 2032]
  • J: 2/4 x 6/8 [711 x 2032]
  • K: 2/0 x 6/8 [610 x 2032]
  • L: 1/6 x 6/8 [457 x 2032]

Upper Floor Plan

Upper Floor Details

  • Upper Floor Area: 1455.27 sq.ft. (134.61 sq.m.)
  • Master Bedroom: Features Walk-in Closet (W.I.C.) and Ensuite.
  • Bonus Room: Located above the garage.
  • Open To Below: Area overlooking the foyer/main level.
  • 36" High guards required for stairs and floor openings as per B.C. Bldg. Code 9.8.7.

Page 81–85

Elevations

Elevation Features

  • Siding: Cedar shingle siding and board & batten siding.
  • Roof: Laminated asphalt shingles with high profile ridge vent caps.
  • Trim: 1x4 and 2x10 fascia trim.
  • Stone: Cultured stone accents on columns and lower walls.
  • Windows: 2x2 and 1x4 window trim.

Limiting Distance Data - Front Elevation

  • Exposed Building Face: 79.74 sq.m.
  • Allowable Openings: 11.0 %
  • Allowable Opening Area: 8.77 sq.m.
  • Proposed Openings: 3.35 sq.m.
  • Limiting Distance: 2.74 m.

Limiting Distance Data - Left Elevation

  • Exposed Building Face: 79.74 sq.m.
  • Allowable Openings: 15.0 %
  • Allowable Opening Area: 11.96 sq.m.
  • Proposed Openings: 9.91 sq.m.
  • Limiting Distance: 3.66 m.
Page 81–85