This site is in beta — data may be incomplete and features are still being added.
Council Meeting/Documents/Drawing A2.0 - Underground Parking Floor Plan
Appendix

Drawing A2.0 - Underground Parking Floor Plan

January 15, 2019Page 1643 sections

Architectural floor plan for the underground parkade, showing 37 underground stalls.

1 CALL TO ORDER
Drawing Number: A2.0Includes workshop, storage, and bike storage

Project Information

Project Title: PROPOSED RESIDENTIAL DEVELOPMENT
Project Address: 242-244 ISLAND HIGHWAY, VICTORIA, BC
Drawing Title: UNDERGROUND PARKING FLOOR PLAN
Architect: alan lowe architect inc.
Architect Address: 118 - 21 Erie St., Victoria, British Columbia
Architect Contact: t 250.360.2888
Project No.: 17-504
Date: 05 NOV 2018
Scale: AS NOTED (Plan scale marked 1:100)
Checked by: LOWE
Drawn by: DM & TS
Sheet No.: A2.0

Page 164

Issue / Revisions

No. Issued / Revisions Date
1 REZONING 19 FEB '18
2 REVISIONS TO REZONING 15 MAY '18
3 DEVELOPMENT PERMIT 25 JUNE '18
4 REVISIONS TO DP 08 NOV '18
Page 164

Plan Details: Underground Parking Floor Plan

General Features and Areas

  • Total Capacity: 37 Underground Stalls (numbered 1-37).
  • Bike Storage: Designated area with 40 racks.
  • Storage (37): A large storage area partitioned for individual stalls.
  • Mechanical/Utility Rooms:
    • MECH. ROOM
    • ELEC. ROOM
    • ELEV. MACH. (Elevator Machine Room)
  • Workshop: Located in the southwest corner.
  • Access/Circulation:
    • Multiple ramps identified (e.g., RAMP DOWN 10m @ 15%, 33.5m @ 3%, 11m @ 6%, 15.5m @ 6% DN).
    • Vestibules (VEST.) providing access to stairs and elevators.
    • Stairs labeled with riser information (e.g., UP 18R @ 6.75'', UP 9R @ 6.75'').
  • Structural Elements:
    • Concrete columns (some noted as 12"x30" - See Structural).
    • Slab bands noted as "SLAB BAND ABOVE".
    • Retaining walls and trench drains (See Mech).
  • Site Boundaries: Labeled with "PROPERTY LINE" and "SETBACK LINE" on all sides.

Notations

  • Copyright: Copyright Reserved: These drawings are at all times the property of the Architect. Reproduction in whole or in part without written consent of the Architect is prohibited.
  • North Arrow: Project North is indicated as being oriented towards the top right of the page.
  • Elevations: Various spot elevations are provided (e.g., -12' 3 1/2" Project 33.50 m Geo.).
  • Specific Stall Notes: Stalls 7, 14, and 15 include a label "SC".

Dimensional Data (Samples)

  • Overall Building Width (A-G): 156'-0" [47.55 m]
  • Overall Building Depth (1-9): 110'-11 1/2" [33.81 m]
  • Standard Stall Widths: Varying between 8'-6 1/2" [2.60 m] and 9'-6" [2.90 m].
  • Drive Aisle Widths: Typically 22'-0" [6.71 m].
Page 164
Extracted from: 2019 01 15 Council Agenda - Agenda - Pdf