Appendix
Attachment 8. Block P Plans - Java Design
April 20, 2021Pages 50–546 sections
Architectural drawings and elevations specifically for Block P of Phase 3.
Block PFoundation and floor plans
Project Information
- Customer: LIMONA HOLDINGS LTD.
- Address: TLC SUBDIVISION
- Issue Date: NOV. 20, 2020
- Drawn By: S.M.
- Checked By: KYLE LEGGETT
- Design Firm: JAVA DESIGNS
Page 50–54
Page 1: Foundation Plan (On Slab)
Drawing Name: BLOCK P: FOUNDATION PLAN Drawing Scale: 1/4" = 1' - 0" Sheet Number: A2
Foundation Plan Notes
- 8" concrete wall on 8x16" conc. ftgs. 2 #4 bar cont. typ. anchor bolts @ 4'
- 4" concrete floor on compacted granular fill, 6 mil poly v.B., R12 rigid perimeter insulation.
- P37 and P39 unit lower: 32"x32"x11" ftgs with 10" pilaster & 6x6 post saddle fir 6x6 post.
- Bulkhead out for garage door: slope concrete to drain away from house.
- Slab Foundation Wall: See cross section.
- Sill Plates/ Rim Joists: See cross section.
Page 50–54
Page 2: Main Floor Plan (8'-0 3/4" Walls)
Drawing Name: BLOCK P: MAIN FLOOR PLAN Drawing Scale: 1/4" = 1' - 0" Sheet Number: A3
Area Summary
- P39 FLOOR AREA: 600.21 Sq Ft (55.76 Sq M)
- P39 GARAGE AREA: 387.76 Sq Ft (36.02 Sq M)
- P38 FLOOR AREA: 619.68 Sq Ft (57.57 Sq M)
- P38 GARAGE AREA: 387.76 Sq Ft (36.02 Sq M)
- P37 FLOOR AREA: 612.18 Sq Ft (56.87 Sq M)
- P37 GARAGE AREA: 384.07 Sq Ft (35.68 Sq M)
- COV. ENTRY AREA: 67 Sq Ft per unit
Plan Notes
- NOTE: TRIPLEX TO BE SPRINKLERED
- SPRINKLER ROOM: 18"X30" CLEAR, INSULATED, HEATED WITH BASEBOARD HEATER, ENCLOSED WITH METAL DOOR.
- GARAGE VEHICULAR DOORS: MUST BE MINIMUM NOMINAL RSI OF 1.1.
- BEDROOM EGRESS: Metal culver window well as per B.C.B.C. 9.9.10.1. 3), 4) & 5) with metal climbable ladder and walkable operable grate at grade.
- All pot light cavities in ceilings, plumbing boxes, fans, electrical panels..... in party walls to be completely sealed and fire rated with type 'X' drywall.
- DEMISING WALL: (1h as per W13a - Table A-9.10.3.1.A)
- two rows 38 mm x 140 mm studs, each spaced 400 mm or 600 mm o.c. on separate 38 mm x 89 mm plates set 25 mm apart.
- 89 mm thick absorptive material on each side.
- 1 layer of 15.9 mm Type X gypsum board on each side.
- Bedroom windows not less than 4 sq.ft. and 15" opening any direction.
- Fume seal garage from living space.
- Self closing hinges, weatherstrip, steel insulated doors at garage entries.
- Interconnected Smoke & CO Detectors to all floors as per BCBC.
Page 50–54
Page 3: Upper Floor Plan (9'-0 3/4" Walls)
Drawing Name: BLOCK P: UPPER FLOOR PLAN Drawing Scale: 1/4" = 1' - 0" Sheet Number: A4
Area Summary
- P39 UPPER FLOOR AREA: 920.96 Sq Ft (85.56 Sq M)
- P38 UPPER FLOOR AREA: 934.44 Sq Ft (86.81 Sq M)
- P37 UPPER FLOOR AREA: 920.17 Sq Ft (85.49 Sq M)
Plan Notes
- NOTE: TRIPLEX TO BE SPRINKLERED
- PRINCIPAL EXHAUST FAN located in laundry/hall areas.
- DIRECT VENT GAS FIREPLACE noted in living rooms.
- PATIO: 10'X10'
- Railings - 42" high non climbable.
- All pot light cavities, demising wall specs, and smoke/CO detector requirements same as Main Floor Plan.
Page 50–54
Page 4: Elevations (Front & Rear)
Drawing Name: BLOCK P: ELEVATIONS Drawing Scale: 1/4" = 1' - 0" Sheet Number: A5
Exterior Finishes Schedule
| Tag | Item | Description |
|---|---|---|
| A | ROOFING | ASPHALT ROOFING WITH RAISED RIDGE & HIP CAPS |
| B | GUTTER & SOFFIT | ALUMINIUM GUTTER AND NON-VENTED SOFFIT |
| C | BARGE BOARD | 2x10 WITH 1x4 DOUBLE BARGE BOARD, PAINTED TRIM COLOUR |
| D | WINDOW & DOOR TRIM | 1x4 TRIM BOARDS - PAINTED/STAINED |
| E | CORNER TRIM | 1x4 CORNER BOARDS - PAINTED/STAINED |
| F1 | WALL FINISH | HARDIE-PLANK SIDING LAPPED TO 6" EXPOSURE - COLOUR AS PER OWNERS SPECS |
| F2 | WALL FINISH | HARDIE BOARD AND BATTEN CHECKER PATTERN - COLOUR AS PER OWNERS SPECS |
| F3 | WALL FINISH | HARDIE-PLANK SIDING LAPPED TO 12" EXPOSURE - COLOUR AS PER OWNERS SPECS |
| G | POSTS | POSTS - PAINTED/STAINED AS PER OWNERS SPECS |
| H | BELLY BAND | 2x12 PAINTED BELLY BAND WITH FLASHING, PAINTED TRIM COLOR |
| I | STONE | K2 STONE - RAIN SCREEN AS PER BCBC |
Elevation Notes
- **ALL WINDOWS MUST COMPLY WITH BCBC AND NAFS REQUIREMENTS**
- MUST BE CLEARLY LABELED ON ALL WINDOW UNITS UPON INSTALLATION FOR INSPECTION.
- ONE EXTERIOR DOOR IS PERMITTED TO HAVE A HIGHER U-VALUE OF 2.6, ALL OTHERS MUST BE LOWER.
- GARAGE VEHICULAR DOORS MUST BE MINIMUM NOMINAL RSI OF 1.1.
Page 50–54
Page 5: Elevations (Left & Right)
Drawing Name: BLOCK P: ELEVATIONS Drawing Scale: 1/4" = 1' - 0" Sheet Number: A6
Left Elevation Data
- EXPOSING BUILDING FACE: 59.22m²
- LIMITING DISTANCE: 2.32m
- AREA OF GLAZED OPENINGS: 3.30m²
- % GLAZED OPENINGS: 5.57%
- 45 min FIRE-RESISTANCE RATING: not required
- TYPE OF CLADDING: no limits
- PERMITTED % OF GLAZED OPENINGS (as per Table 9.10.15.4): 14.50%
- PERMITTED AGGREGATE AREA OF GLAZED OPENINGS: 8.59m²
Right Elevation Data
- EXPOSING BUILDING FACE: 45.71m²
- LIMITING DISTANCE: 7.04m
- AREA OF GLAZED OPENINGS: 2.65m²
- % GLAZED OPENINGS: 5.80%
- 45 min FIRE-RESISTANCE RATING: not required
- TYPE OF CLADDING: no limits
- PERMITTED % OF GLAZED OPENINGS (as per Table 9.10.15.4): 78.50%
- PERMITTED AGGREGATE AREA OF GLAZED OPENINGS: 35.88m²
Elevation Vertical Benchmarks (Geodetic)
- HIGHEST ROOF MIDPOINT: 121'-2" (69.80m Geo.)
- UPPER FLOOR CEILING: 114'-5" (67.74m Geo.) / 118'-2" (68.88m Geo.)
- UPPER FLOOR: 105'-4" (64.97m Geo.) / 109'-1" (66.11m Geo.)
- MAIN FLOOR CEILING: 104'-4" (64.67m Geo.) / 108'-1" (65.81m Geo.)
- MAIN FLOOR: 96'-3" (62.20m Geo.) / 100' (63.34m Geo.)
- AVRG. FINISHED GRADE: 102'-2" (64.00m Geo.)
- FINISHED GRADE: 95'-9" (62.05m Geo.) / 99'-6" (63.19m Geo.)
Page 50–54