Appendix
Attachment 14. Grading Plan (updated) - Associated Engineering
April 20, 2021Page 681 section
West Park at Thetis Phase 3 - Civil Grading Plan
General Notes
- GEOTECHNICAL AND STRUCTURAL DESIGN OF RETAINING WALLS, BOULDER WALLS, AND ROCK CUTS BY OTHERS.
- 1.5 m WIDE BENCHES REQUIRED WHERE CUT SLOPES OVER 6 m - GEOTECH ENGINEER TO CERTIFY ALL ROCK CUTS AND BOULDER STACKED WALLS.
- 2:1 BOULDER STACKED WALL REQUIRED (TO BE MONITORED AND CERTIFIED BY GEOTECHNICAL ENGINEER).
- 1 m HIGH BOULDER STACKED WALL BETWEEN 1.5:1 SLOPES (TYP) TO BE MONITORED & CERTIFIED BY RYZUK.
- 1 m HIGH BOULDER STACKED WALL TO BE MONITORED & CERTIFIED BY RYZUK.
Legend
| Symbol | Description |
|---|---|
| G=49.40 | AVERAGE GARAGE ELEVATION |
| (89.561) | ROAD CENTERLINE FINISHED GRADE |
| 67.350 | FINISHED GRADE |
| 92.10 | DESIGN SUBGRADE/PAD ELEVATION |
| 90.46 | ORIGINAL GROUND |
| 3.7 | WALL HEIGHT (FILL) |
| 2.2 | SIDE YARD WALL HEIGHT |
Rear Yard Walkout Types
- TYPE U: SG 0.30, FG 0.45
- TYPE M: SG 0.40
- TYPE L: SG 0.45
Revision History
| REV | DATE | DESIGN | DRAWN | DESCRIPTION |
|---|---|---|---|---|
| A | 2020SEP14 | DD | DH | ISSUED FOR PRICING |
| B | 2020NOV6 | DD | DH | ISSUED FOR PLUMBING PERMIT |
| C | 2021MAR18 | DD | DH | ISSUED FOR PRICING |
Project Information
- Client: LIMONA CONSTRUCTION
- Project Title: WEST PARK AT THETIS PHASE 3
- Project Number: 2016-2253-00
- Drawing Title: CIVIL GRADING PLAN
- Scale: 1:250
- Drawing Number: 2253-00-C-301
- Revision: C
- Sheet: 6
- Firm: Associated Engineering (DRAFT - PRELIMINARY/FOR DISCUSSION - NOT FOR CONSTRUCTION)
Page 68
Extracted from: 2021 04 20 Council Agenda - Agenda - Pdf