Appendix
Attachment 8: Conceptual Site Servicing Plan
May 4, 2021Page 1261 section
Technical drawing showing the underground utilities and servicing connections for the development.
Shows underground storm water detention tanks
7 ERSKINE LANE RE-DEVELOPMENT
CONCEPTUAL SITE SERVICING PLAN
Project Notes and Annotations:
- WATERMAIN UPGRADE LIKELY REQUIRED TO ACCOMMODATE MAXIMUM ALLOWABLE FIRE FLOW VELOCITY.
- RELOCATE EXISTING CB IN FRONT OF PROPOSED S/W.
- POSSIBLE FUTURE SRW ON 9 ERSKINE LANE FOR FUTURE SIDEWALK.
- 3m TRIANGLE SRW ON 7 ERSKINE LANE FOR PROPOSED SIDEWALK.
- NEW WATER SERVICE C/W DOMESTIC METER AND DOMESTIC / FIRE BACKFLOW PREVENTOR.
- VIEW ROYAL CREWS TO INSTALL NEW DRAIN SERVICE.
- PROPOSED GAS SERVICE.
- VIEW ROYAL CREWS TO INSTALL NEW SANITARY SERVICE.
- PROPOSED MULTI-UNIT RESIDENTIAL BUILDING OVER CONCRETE PARKING STRUCTURE (70 UNITS).
- STORMWATER TREATMENT WITHIN PLANTED AREAS.
- STORMWATER DETENTION BENEATH PARKING LOT.
- REMOVAL OF EXISTING PRIVATE HYDRO POLES TO BE CONFIRMED.
- FIRE TRUCK STAGING LOCATION.
- EXISTING STORMWATER DISCHARGE TO CRAGFLOWER CREEK.
- EXISTING FLUSH VALVE.
- CONCEPTUAL PMT LOCATION.
- ACCESS TO STAGING AREA NOT MORE THAN 8% IN GRADE.
- FIRE TRUCK TURNING TEMPLATE.
CONFIRM UNDERGROUND LOCATIONS WITH UTILITY COMPANIES THE LOCATION AND ELEVATION OF THE EXISTING UNDERGROUND INFRASTRUCTURE SHOWN ON THIS DRAWING MAY NOT BE ACCURATE OR COMPLETE. THE ACTUAL HORIZONTAL AND VERTICAL LOCATIONS MUST BE CONFIRMED PRIOR TO THE START OF ANY EXCAVATION.
Legend
| Symbol/Line | Description | Symbol/Line | Description |
|---|---|---|---|
| ————— | Existing Municipal Infrastructure | ————— | Proposed Municipal Infrastructure |
| ——— I ——— | Existing External U/G Utilities | ——— I ——— | Proposed External U/G Utilities |
| --- D --- | Drain | --- DT --- | Ditch |
| --- S --- | Sewer | --- W --- | Water |
| ——— | Curb | S/W | Sidewalk |
| [Symbol] | Manhole | [Symbol] | Cleanout |
| [Symbol] | Culvert | [Symbol] | Concrete Box |
| [Symbol] | Wood Box | [Symbol] | Catch Basin |
| [Symbol] | Reducer | [Symbol] | Cap / Plug |
| [Symbol] | Water Meter | [Symbol] | Valve |
| [Symbol] | Flush Valve | [Symbol] | Hydrant |
| [Symbol] | Air Valve | [Symbol] | Traffic Sign |
| [Symbol] | Silt Trap | [Symbol] | Ctrl Monument |
| [Symbol] | Traverse Hub | [Symbol] | Gas Valve |
| [Symbol] | Street Lighting | [Symbol] | Pole Mount |
| [Symbol] | Post Top | [Symbol] | Pedestrian Signal |
| [Symbol] | Standard Mount | [Symbol] | Traffic Signal |
Revisions Approved
| Revision | Approved | Date | Signed |
|---|---|---|---|
| REVISION # 1 | |||
| REVISION # 2 | |||
| REVISION # 3 |
Design Approved
| Position | Approved By | Date | Signed |
|---|---|---|---|
| Design Engineer | |||
| Manager of Development | |||
| Development Coordinator |
Location Plan Details:
- OVIC ADDRESS: 7 ERSKINE LANE, LOT A, TOWN OF VIEW ROYAL, PLAN VIP57062
Project Information:
- Date: JANUARY 21, 2021
- Status: ISSUED FOR DEVELOPMENT PERMIT
- Town: TOWN OF VIEW ROYAL
- Project: 7 ERSKINE LANE
- Drawing: CONCEPTUAL SITE SERVICING PLAN
- Firm: ISLANDER ENGINEERING
- 400-G GARBALLY RD, VICTORIA, B.C. V8T 2K1
- PHONE: 250.590.3550
- Scale: 1:200
- File #: 2046
- Drawing #: C01
- Date (Drafted): 2021-01-21
- Sheet: 1 OF 1
Page 126