Appendix
Block B Elevations
May 19, 2020Page 2604 sections
Exterior elevation views for the Block B townhouse structure.
Materials include mullioned window treatments and natural toned cementitious materials
Project Information
Customer: Limona Holdings Ltd. Address: TLC Subdivision Drawing Name: Block B: Elevations Issue Date: April 03, 2020 Drawn By: JA Checked By: Kyle Leggett Drawing Scale: 1/4" = 1'-0" Sheet Number: B5
Page 260
Elevations
Front Elevation
Scale: 1/4" = 1'-0"
Elevation Heights:
- Highest Roof Midpoint: 121'-7" (36.14m Geo.)
- Upper Floor Ceiling: 118'-2" (37.03m Geo.)
- Upper Floor: 110'-1" (33.56m Geo.)
- Main Floor Ceiling: 109'-1" (34.75m Geo.)
- Main Floor: 100'-0" (31.09m Geo.)
- Finished Grade: 99'-6" (31.83m Geo.)
Left Elevation
Scale: 1/4" = 1'-0"
Exposing Building Face Statistics:
- Exposing Building Face: 55.39m²
- Limiting Distance: 1.55m
- Area of Glazed Openings: 0.48m²
- % Glazed Openings: 0.72%
- 45 min Fire-Resistance Rating: not required
- Type of Cladding: no limits
- Permitted % of Glazed Openings (as per Table 9.10.15.4): 8.00%
- Permitted Aggregate Area of Glazed Openings: 4.43m²
Rear Elevation
Scale: 1/4" = 1'-0"
Right Elevation
Scale: 1/4" = 1'-0"
Exposing Building Face Statistics:
- Exposing Building Face: 57.92m²
- Limiting Distance: 1.55m
- Area of Glazed Openings: 0.48m²
- % Glazed Openings: 0.83%
- 45 min Fire-Resistance Rating: not required
- Type of Cladding: no limits
- Permitted % of Glazed Openings (as per Table 9.10.15.4): 8.00%
- Permitted Aggregate Area of Glazed Openings: 4.63m²
Page 260
Exterior Finishes Schedule
| Code | Category | Description |
|---|---|---|
| A | ROOFING: | ASPHALT ROOFING WITH RAISED RIDGE & HIP CAPS |
| B | GUTTER & SOFFIT: | ALUMINUM GUTTER AND NON-VENTED SOFFIT |
| C | BARGE BOARD: | 2x10 WITH 1x4 DOUBLE BARGE BOARD, PAINTED TRIM COLOUR |
| D | WINDOW & DOOR TRIM: | 1x4 TRIM BOARDS - PAINTED / STAINED |
| E | CORNER TRIM: | 1x4 CORNER BOARDS - PAINTED / STAINED |
| F1 | WALL FINISH: | HARDIE PLANK SIDING LAPPED TO 6" EXPOSURE - COLOUR AS PER OWNERS SPECS |
| F2 | WALL FINISH: | HARDIE BOARD AND BATTEN CHECKER PATTERN - COLOUR AS PER OWNERS SPECS |
| G | BELLY BAND: | 2x10 PAINTED BELLY BAND WITH FLASHING, PAINTED TRIM COLOUR |
| H | POSTS: | POSTS, PAINTED/STAINED AS PER OWNERS SPECS |
Page 260
General Notes
Window and Door Requirements:
- ALL WINDOWS MUST COMPLY WITH BCBC AND NAFS REQUIREMENTS.
- MUST BE CLEARLY LABELED ON ALL WINDOW UNITS UPON INSTALLATION FOR INSPECTION.
- ONE EXTERIOR DOOR IS PERMITTED TO HAVE A HIGHER U-VALUE OF 2.6, ALL OTHERS MUST BE LOWER.
- GARAGE VEHICULAR DOORS MUST BE MINIMUM NOMINAL RSI OF 1.1.
NAFS Requirements:
- Performance Grade of 30
- Water Test Pressure of 260 Pa
JAVA DESIGNS WHERE LINES ON PAPER BECOME WALLS ON SITE Ph: 250.590.2468 | F: 250.590.4577 | www.javadesigns.ca