This site is in beta — data may be incomplete and features are still being added.
Council Meeting/Documents/Block B Elevations
Appendix

Block B Elevations

May 19, 2020Page 2604 sections

Exterior elevation views for the Block B townhouse structure.

1 CALL TO ORDER
Materials include mullioned window treatments and natural toned cementitious materials

Project Information

Customer: Limona Holdings Ltd. Address: TLC Subdivision Drawing Name: Block B: Elevations Issue Date: April 03, 2020 Drawn By: JA Checked By: Kyle Leggett Drawing Scale: 1/4" = 1'-0" Sheet Number: B5


Page 260

Elevations

Front Elevation

Scale: 1/4" = 1'-0"

Elevation Heights:

  • Highest Roof Midpoint: 121'-7" (36.14m Geo.)
  • Upper Floor Ceiling: 118'-2" (37.03m Geo.)
  • Upper Floor: 110'-1" (33.56m Geo.)
  • Main Floor Ceiling: 109'-1" (34.75m Geo.)
  • Main Floor: 100'-0" (31.09m Geo.)
  • Finished Grade: 99'-6" (31.83m Geo.)

Left Elevation

Scale: 1/4" = 1'-0"

Exposing Building Face Statistics:

  • Exposing Building Face: 55.39m²
  • Limiting Distance: 1.55m
  • Area of Glazed Openings: 0.48m²
  • % Glazed Openings: 0.72%
  • 45 min Fire-Resistance Rating: not required
  • Type of Cladding: no limits
  • Permitted % of Glazed Openings (as per Table 9.10.15.4): 8.00%
  • Permitted Aggregate Area of Glazed Openings: 4.43m²

Rear Elevation

Scale: 1/4" = 1'-0"

Right Elevation

Scale: 1/4" = 1'-0"

Exposing Building Face Statistics:

  • Exposing Building Face: 57.92m²
  • Limiting Distance: 1.55m
  • Area of Glazed Openings: 0.48m²
  • % Glazed Openings: 0.83%
  • 45 min Fire-Resistance Rating: not required
  • Type of Cladding: no limits
  • Permitted % of Glazed Openings (as per Table 9.10.15.4): 8.00%
  • Permitted Aggregate Area of Glazed Openings: 4.63m²

Page 260

Exterior Finishes Schedule

Code Category Description
A ROOFING: ASPHALT ROOFING WITH RAISED RIDGE & HIP CAPS
B GUTTER & SOFFIT: ALUMINUM GUTTER AND NON-VENTED SOFFIT
C BARGE BOARD: 2x10 WITH 1x4 DOUBLE BARGE BOARD, PAINTED TRIM COLOUR
D WINDOW & DOOR TRIM: 1x4 TRIM BOARDS - PAINTED / STAINED
E CORNER TRIM: 1x4 CORNER BOARDS - PAINTED / STAINED
F1 WALL FINISH: HARDIE PLANK SIDING LAPPED TO 6" EXPOSURE - COLOUR AS PER OWNERS SPECS
F2 WALL FINISH: HARDIE BOARD AND BATTEN CHECKER PATTERN - COLOUR AS PER OWNERS SPECS
G BELLY BAND: 2x10 PAINTED BELLY BAND WITH FLASHING, PAINTED TRIM COLOUR
H POSTS: POSTS, PAINTED/STAINED AS PER OWNERS SPECS

Page 260

General Notes

Window and Door Requirements:

  • ALL WINDOWS MUST COMPLY WITH BCBC AND NAFS REQUIREMENTS.
  • MUST BE CLEARLY LABELED ON ALL WINDOW UNITS UPON INSTALLATION FOR INSPECTION.
  • ONE EXTERIOR DOOR IS PERMITTED TO HAVE A HIGHER U-VALUE OF 2.6, ALL OTHERS MUST BE LOWER.
  • GARAGE VEHICULAR DOORS MUST BE MINIMUM NOMINAL RSI OF 1.1.

NAFS Requirements:

  • Performance Grade of 30
  • Water Test Pressure of 260 Pa

JAVA DESIGNS WHERE LINES ON PAPER BECOME WALLS ON SITE Ph: 250.590.2468 | F: 250.590.4577 | www.javadesigns.ca

West Park at Thetis Lake

Page 260
Extracted from: 2020 05 19 Council Agenda - Agenda - Pdf