Appendix
Block C Elevations
May 19, 2020Page 2656 sections
Exterior elevation views for the Block C building, showing contemporary West Coast design elements.
Highest Roof Midpoint: 121'-11 1/2"
Project Information
Customer: Limona Holdings Ltd. Address: TLC Subdivision Drawing Name: Block C: Elevations Drawing Scale: 1/4" = 1'-0" Issue Date: April 03, 2020 Drawn By: KC Checked By: Kyle Leggett Project Name: West Park at Thetis Lake Sheet Number: C5 Designer: JAVA DESIGNS Designer Contact: Ph: 250.590.2468 | F: 250.590.4577 | www.javadesigns.ca
Page 265
Exterior Finishes Schedule
| Key | Finish Type | Description |
|---|---|---|
| A | ROOFING | ASPHALT ROOFING WITH RAISED RIDGE & HIP CAPS |
| B | GUTTER & SOFFIT | ALUMINUM GUTTER AND NON-VENTED SOFFIT |
| C | BARGE BOARD | 2x10 WITH 1x4 DOUBLE BARGE BOARD, PAINTED TRIM COLOUR |
| D | WINDOW & DOOR TRIM | 1x4 TRIM BOARDS - PAINTED/STAINED |
| E | CORNER TRIM | 1x4 CORNER BOARDS - PAINTED/STAINED |
| F1 | WALL FINISH | HARDIE-PLANK SIDING LAPPED TO 4" EXPOSURE - COLOUR AS PER OWNERS SPECS |
| F2 | WALL FINISH | HARDIE BOARD AND BATTEN 12" O.C. BATTEN PATTERN - COLOUR AS PER OWNERS SPECS |
| F3 | WALL FINISH | HARDIE-PLANK SIDING LAPPED TO 4" EXPOSURE - COLOUR AS PER OWNERS SPECS |
| G | BELLY BAND | 2x10 PAINTED BELLY BAND WITH FLASHING, PAINTED TRIM COLOR |
| H | POSTS | POSTS - PAINTED/STAINED AS PER OWNERS SPECS |
Page 265
Building Elevations
Front Elevation
Scale: 1/4" = 1' - 0"
Rear Elevation
Scale: 1/4" = 1' - 0"
Left Elevation
Scale: 1/4" = 1' - 0"
Right Elevation
Scale: 1/4" = 1' - 0"
Page 265
Vertical Elevation Points
- HIGHEST ROOF MIDPOINT: 120'-11 1/2" (61.02m Geo.)
- UPPER FLOOR CEILING: 119'-2" (60.17m Geo.)
- UPPER FLOOR: 110'-1" (57.21m Geo.)
- MAIN FLOOR CEILING: 109'-1" (57.40m Geo.)
- MAIN FLOOR: 100'-0" (54.63m Geo.)
- AVG FINISHED GRADE: 99'-6" (54.48m Geo.)
Page 265
Exposing Building Face Data (Left and Right Elevations)
- EXPOSING BUILDING FACE: 55.39m²
- LIMITING DISTANCE: 1.55m
- AREA OF GLAZED OPENINGS: 0.50m²
- % GLAZED OPENINGS: 0.90%
- 45 min FIRE-RESISTANCE RATING: not required
- TYPE OF CLADDING: no limits
- PERMITTED % OF GLAZED OPENINGS (as per Table 9.10.15.4): 8.51%
- PERMITTED AGGREGATE AREA OF GLAZED OPENINGS: 4.71m²
Page 265
General Notes
- ALL WINDOWS MUST COMPLY WITH BCBC AND NAFS REQUIREMENTS
- MUST BE CLEARLY LABELLED ON ALL WINDOW UNITS UPON INSTALLATION FOR INSPECTION.
- ONE EXTERIOR DOOR IS PERMITTED TO HAVE A HIGHER U-VALUE OF 2.6, ALL OTHERS MUST BE LOWER.
- GARAGE VEHICULAR DOORS MUST BE MINIMUM NOMINAL RSI OF 1.1.
Page 265
Extracted from: 2020 05 19 Council Agenda - Agenda - Pdf