This site is in beta — data may be incomplete and features are still being added.
Council Meeting/Documents/Attachment 12 - Typical Type C Elevations
Appendix

Attachment 12 - Typical Type C Elevations

February 2, 2016Page 361 section

Detailed drawings of the front, rear, and side elevations for Type C buildings.

8.1.a Development Permit No. 2015/12 - 102 Atkins Road
January 25, 2016

TYPICAL TYPE C ELEVATIONS

Full architectural drawing sheet showing four typical elevations—front, right side, rear, and left side—for Type C homes at 102 Atkins Road
Full architectural drawing sheet showing four typical elevations—front, right side, rear, and left side—for Type C homes at 102 Atkins Road

Front Elevation C1

Scale: 1/4" = 1'-0"

  • Decorative knee brace
  • 1x4 trim on 2x10 fascia trim
  • Knee brace
  • Board and batten siding
  • Laminated asphalt shingles
  • Pre-fin. metal roofing
  • 1x4 door and window trim
  • Conc. fibre lap siding
  • Pre-fin. alumn. gutter
  • 1x4 corner trim
  • Pre-manuf. stone veneer
  • Tapered capital trim
Close-up architectural detail of window configuration and siding materials on Type C elevations
Close-up architectural detail of window configuration and siding materials on Type C elevations

Right Side Elevation C2

Scale: 1/4" = 1'-0"

  • Decorative knee brace
  • 1x4 trim on 2x10 fascia trim
  • Board and batten siding
  • Laminated asphalt shingles
  • Pre-fin. metal roofing
  • Knee brace
  • Conc. fibre lap siding
  • 1x4 corner trim
  • Metal flashing on 2x12 fascia
  • Tapered capital trim
  • Pre-manuf. stone veneer
  • Decorative knee brace (lower level)

Rear Elevation C3

Scale: 1/4" = 1'-0"

  • Decorative knee brace
  • Laminated asphalt shingles
  • 1x4 trim on 2x10 fascia trim
  • Pre-fin. metal roofing
  • Pre-fin. alumn. gutter
  • 1x4 door and window trim
  • Conc. fibre lap siding
  • Custom fascia trim
  • Metal flashing on 2x12 fascia
  • 1x4 corner trim

Left Side Elevation C4

Scale: 1/4" = 1'-0"

  • Laminated asphalt shingles
  • Pre-fin. metal roofing
  • Knee brace
  • 1x4 door and window trim
  • Cedar shingle siding
  • Conc. fibre lap siding
  • Metal flashing on 2x12 fascia
  • Tapered capital trim
  • Pre-manuf. stone veneer

Project Information

  • Project: development permit, 102 ATKINS ROAD, VIEW ROYAL B.C.
  • Contractor: EN VIRO TEC GENERAL CONTRACTING LTD.
  • Design Firm: VICTORIA DESIGN GROUP
  • Drawing #: 7548
  • Scale: 1/4" = 1'0"
  • Drawn by: NS
  • Date: 25/1/16
Page 36
Extracted from: 2016 02 02 Council Agenda - Pdf