This site is in beta — data may be incomplete and features are still being added.
Council Meeting/Documents/ACCESS ROAD AND SOUTH PROPERTY LINE SECTIONS (Attachment 22)
Appendix

ACCESS ROAD AND SOUTH PROPERTY LINE SECTIONS (Attachment 22)

October 18, 2016Page 971 section

Cross-sectional diagrams of site grading and road alignments.

Date: July 8, 2016Plan Number: 2623PH2-C02

EAGLE CREEK VILLAGE

OMICRON DEVELOPMENTS LTD.

ACCESS ROAD AND SOUTH PROPERTY LINE SECTIONS

Engineering cross-sections for Access Road and South Property Line
Engineering cross-sections for Access Road and South Property Line
Engineering cross-sections for Access Road and South Property Line (negative contrast rendering)
Engineering cross-sections for Access Road and South Property Line (negative contrast rendering)

NOT FOR CONSTRUCTION

REVISIONS

No. Description Date
1 DEV'T BUILDING LDC'N AS PER CLIENT COMMENT 2016.07.05
2 REVISED PARKING LOT AS PER CLIENT COMMENT 2016.03.18
3 REVISED DESIGN & ACCESS ROAD ALIGNMENTS 2016.01.11
4 RE-ISSUED FOR DEVELOPMENT PERMIT 2015.12.11
5 ISSUED FOR DEVELOPMENT PERMIT 2013.06.12

PROJECT INFORMATION

  • Consultant: WESTBROOK Consulting Ltd.
  • Address: #115 - 985 Goldstream Ave., Victoria, BC V9B 0J3
  • Telephone: 250-391-8592
  • Facsimile: 250-391-8593
  • Project No: 2623
  • Drawing No: 2623PH2-C02
  • Sheet: 2 of 2
  • Revision: 4
  • Date: APR 2013
  • Scale: Horiz. 1:250, Vert. 1:250
  • Designed: MH / PC
  • Drawn: PC
  • Checked: MH

SECTIONS ACCESS ROAD

Cross-sections provided at the following stations:

  • 1+00.000
  • 1+10.000 (Note: EXISTING GROUND NOV 15 2012)
  • 1+20.000 (Note: SEE ARCHITECTURAL AND SECTION DRAWINGS FOR DETAILS OF PROPOSED RETAINING WALL)
  • 1+30.000
  • 1+40.000
  • 1+50.000 (Note: EXIST. BLDG. MFF 27.20)
  • 1+60.000
  • 1+70.000
  • 1+80.000
  • 1+90.000
  • 2+00.000
  • 2+10.000

SECTIONS SOUTH PROPERTY LINE

Cross-sections provided at the following stations:

  • 6+05.000
  • 6+10.000
  • 6+20.000 (Note: EXISTING GROUND)
  • 6+30.000
  • 6+40.000
  • 6+50.000
  • 6+57.000
  • 6+80.000
  • 6+90.000 (Note: PROPOSED RETAINING WALL)
  • 6+97.589 (Notes: PROPOSED FINISHED GROUND, EXISTING GROUND)
  • 7+00.000

GENERAL DIAGRAM ANNOTATIONS

  • EXISTING GROUND
  • PROPOSED FINISHED GROUND
  • EDGE OF BUILDING
  • PROPOSED RETAINING WALL
Page 97

Document Images

(1)
Document image
Extracted from: 2016 10 18 Council Agenda - Pdf