This site is in beta — data may be incomplete and features are still being added.
Committee of the Whole/Documents/Attachment 6: Conceptual Servicing Drawing
Appendix

Attachment 6: Conceptual Servicing Drawing

January 14, 2025Page 1651 section

Civil engineering drawing showing the proposed layout of water, storm, and sanitary services for the development site.

1 CALL TO ORDER- Mayor Tobias called the meeting to order at 3:30 p.m.
Date: November 18, 2024Includes proposed 50m water service and 150m sanitary service extension

Conceptual Servicing Drawing - 14/142 Helmcken Road and 6 Camden Ave

Sheet Notes

  1. Existing water service to be capped & abandoned by CRD forces at developer's expense.
  2. Cap and abandon existing sanitary service by View Royal forces at developer's expense.
  3. Proposed 50mm water service by CRD forces at developer's expense. Backflow preventer to be installed onsite (by contractor).
  4. Proposed 150mm sanitary service by View Royal forces at developer's expense.
  5. Proposed 200mm storm main extension and service to property (routing to be confirmed during detailed design). Connection to existing manhole by View Royal forces at developer's expense. Rebench manhole as required.
  6. Utility box to remain. Sidewalk to be adjusted if required to suit.

Notes

  1. For building information, see drawings by Union Architecture.
  2. For landscaping including trees (proposed, to be removed and to remain), see drawings by Green Space Designs.
  3. Utility sizes and locations to be confirmed during detailed design and are subject to change.
  4. Fire Department connection locations (if required) to be confirmed.
  5. Hydro service to be provided via pole mounted transformer.
  6. All existing houses, driveways, retaining walls, sheds, etc. to be removed and disposed off-site.
  7. Installation of gas, if required, to be coordinated with FortisBC during detailed design.

Drawing Annotations

  • !!CAUTION!! LARGE DIAMETER WATER MAINS ON HELMCKEN
  • SIDEWALK LOCATION PROPOSED IN EFFORT TO RETAIN EXISTING TREES
  • PROPOSED EXTENT OF ASPHALT REMOVAL/REPAVEMENT
  • STORM DETENTION TANKS TO PROVIDE MIN 7.0 CU.M. OF DETENTION
  • OVERLAND FLOW ROUTE DURING LARGE RAINFALL EVENTS
  • SHARED BIKE AND CAR LANE PAINT MARKING (TYP)

Benchmark

Drawing coordinates are local, based on UTM NAD 83 reference monument MON No. 85H3083

  • Northing: 5368855.853
  • Easting: 468628.035
  • Elevation: 27.600m
  • Mean C.S.F. = 0.9996106 All distances are ground level distances and elevations are geodetic elevations.

Revision Table

No. Date By Issued
4 2024-11-18 ND ISSUED FOR DEVELOPMENT PERMIT
3 2024-09-12 ND ISSUED FOR DEVELOPMENT PERMIT
2 2023-09-11 ND ISSUED FOR DEVELOPMENT PERMIT
1 2022-08-06 ND ISSUED FOR REZONING AND DEVELOPMENT PERMIT

Project Information

  • Project: 14/142 Helmcken Road and 6 Camden Ave, View Royal, B.C.
  • Title: Conceptual Servicing Drawing
  • Date: November 18, 2024
  • Project No.: 21-077
  • Drawing No.: 21-077-CSP
  • Scale: Horiz: 1:200 | Vert: N/A
  • Firm: McElhanney Ltd.
  • Address: 500 - 3960 Quadra Street, Victoria, BC V8X 4A3
  • Phone: (250) 370-9221
  • Permit Number: 1003299