Appendix
Attachment 8 CONCEPTUAL SERVICING PLAN
September 14, 2021Page 1711 section
Engineering drawing showing proposed connections to storm, sewer, and water mains.
171 ISLAND HIGHWAY - CONCEPTUAL SERVICING
Project Information
- Project Title: 171 Island Highway
- Drawing Title: Conceptual Servicing
- Date: June 18, 2021
- Project No.: 21-060
- Drawing No.: 21-060-REZONING
- Scale: Horiz: 1:250, Vert: N/A
- Issued for: Rezoning
Notes
- FOR BUILDING INFORMATION, SEE URBAN WEST ARCHITECTURE INC. DRAWINGS.
- FOR LEGAL INFORMATION, SEE WAY HAYENBURG LAND SURVEYING INC. DRAWINGS.
- FOR LANDSCAPING INFORMATION, SEE DRAWINGS BY A SITE LANDSCAPE ARCHITECTURE.
- UTILITY SIZES AND LOCATIONS TO BE CONFIRMED DURING DETAILED DESIGN.
- FIRE DEPARTMENT CONNECTION LOCATION (NOT SHOWN) TO BE CONFIRMED DURING DETAILED DESIGN (TO BE WITHIN 45m OF FIRE HYDRANT).
- ALL EXISTING ON-SITE BUILDINGS, DRIVEWAYS, PARKING LOTS, RETAINING WALLS, ETC. TO BE REMOVED AND DISPOSED OFF-SITE.
- BASE INFORMATION SHOWN IS PRODUCED FROM A COMBINATION OF FIELD SURVEY AND RECORD DRAWING INFORMATION. ALL INFORMATION TO BE CONFIRMED IN THE FIELD PRIOR TO CONSTRUCTION (INCLUDING COMPLETING A BConeCall).
- IRRIGATION SLEEVES TO BE INSTALLED ACROSS DRIVEWAYS/PARKING/SIDEWALKS AS REQUIRED.
Legend
- Existing tree to be removed: (Indicated by red circle with 'X')
- Proposed tree: (Indicated by green circle) See landscape drawings.
Revisions
| NO. | DATE | BY | REVISIONS |
|---|---|---|---|
| 1 | 2021-06-17 | NCD | ISSUED FOR REZONING |
Site Annotations
- Proposed Driveway: Proposed 4.00m wide 200mm thick driveway crossing per MMCD STD. DWG. C7.
- Island Highway Improvements:
- Adjustment of hydro vault/lids to be coordinated with BC Hydro (if required).
- Cap and abandon existing storm services.
- Cap and abandon existing water service.
- Repair asphalt as required for driveway installation.
- Ex. utility manhole lid to be adjusted to suit sidewalk elevation.
- Repair asphalt and curb as required for water service installation.
- Cap and abandon existing hydro & tel services.
- Existing boulevard to be removed for water service installation if required (and reinstated following construction).
- Water Service: Proposed water meter vault in SRW if possible. Vault to be installed in road R.O.W. (To be confirmed during detailed design).
- Storm Service:
- Proposed 250ø storm service c/w inspection chamber. Install inspection chamber 0.3m from property line. Size and location of existing storm service to be confirmed. If existing is less than 250ø, service to be replaced to main with new 250ø service.
- Flow control manhole (details to be confirmed during detailed design).
- Stormwater storage tanks. Storage volume required = 25.1m³. (Details to be confirmed during detailed design).
- Sanitary Service: Proposed 200ø sanitary sewer service. Manhole to be installed on existing sanitary sewer. Main downstream of manhole to be upsized if required.
- General Site:
- Ex. utility pole to be removed.
- Extent of underground parking (see architectural).
- Proposed Building (see architectural).
- Lot 2, Plan 6032, #171.
- Lot A, Plan 34842, #169.
- Parcel D of Section 2, Plan DD810641 (Portage Park).
Page 171