Site Plan with Proposed Footprints
A detailed layout map showing the combined site area and the specific footprints of the three proposed buildings.
EAGLE'S NEST - SITE PLAN
Project Information
Client: BOARDWALK PROPERTIES Project Name: EAGLE'S NEST Address: 3 HELMECKEN ROAD, VIEW ROYAL, BC Drawing Title: SITE PLAN WITH PROPOSED FOOTPRINTS Drawing Number: V-1-SK Project Number: 2241 Revision: 0 Date: 2021-10-29
Site Overview
Combined Site Area: 1.37 ha Proposed Development: Footprint of proposed buildings identified as BLDG 1, BLDG 2, and BLDG 3.
Property Details
The combined site and adjacent properties are identified as follows:
- Combined Site Components:
- LOT 2 Plan VIP3963 (PID: 006-114-946)
- REM LOT 1 Plan VIP3963 (PID: 000-295-981)
- Adjacent Properties:
- REM LOT A Plan VIP1726
- LOT 1 Plan VIP18753 (PID: 000-300-365)
- LOT 1 Plan VIP18347
- REM LOT 22 Plan VIP361
- BUILDING STRATA Plan VIS5633
- LOT 10 Plan VIP1726 (PID: 007-028-156)
Legend
- FFE: FIRST FLOOR ELEVATION
- BFE: BASEMENT FLOOR ELEVATION
- GFE: GARAGE FLOOR ELEVATION
Notes
- THE SURVEY IS ON A LOCAL GROUND SYSTEM AND WAS DERIVED FROM GEODETIC CONTROL MONUMENTS 80H3083 AND 80H3064.
- TO CONVERT TO UTM: MULTIPLY BY THE COMBINED SCALE FACTOR OF 0.9996106, ABOUT GEODETIC CONTROL MONUMENT 80H3083.
- ELEVATIONS ARE IN METRES AND ARE REFERRED TO GEODETIC DATUM CVD28GVRD USING MONUMENT 80H3083, ELEVATION=27.652 METRES.
- THIS PLAN REPRESENTS FIELD SURVEY CONDUCTED ON FEBRUARY 15-17, 2018.
- PROPOSED BUILDINGS FROM DWG "211025 Eagles Nest_A203.DWG" PROVIDED BY CLIENT.
- CONTOUR INTERVAL IS 0.5m.
Revision History
| Rev | Date | Description | Surv | Drawn | App'd |
|---|---|---|---|---|---|
| 0 | 2021-10-29 | ORIGINAL ISSUE | SA | VE | GQ |
Professional Information
Consultant: McElhanney Suite 500, 3960 Quadra Street Victoria BC, Canada V8X 4A3 Tel 250 370 9221
Legal Disclaimer
THIS DRAWING AND DESIGN IS THE PROPERTY OF McELHANNEY CONSULTING SERVICES LTD. (McELHANNEY) AND SHALL NOT BE USED, REUSED OR REPRODUCED WITHOUT THE CONSENT OF McELHANNEY. McELHANNEY WILL NOT BE HELD RESPONSIBLE FOR THE IMPROPER OR UNAUTHORIZED USE OF THIS DRAWING AND DESIGN.
THIS DRAWING AND DESIGN HAS BEEN PREPARED FOR THE CLIENT IDENTIFIED, TO MEET THE STANDARDS AND REQUIREMENTS OF THE APPLICABLE PUBLIC AGENCIES AT THE TIME OF PREPARATION. McELHANNEY, ITS EMPLOYEES, SUBCONSULTANTS AND AGENTS WILL NOT BE LIABLE FOR ANY LOSSES OR OTHER CONSEQUENCES RESULTING FROM THE USE OR RELIANCE UPON, OR ANY CHANGES MADE TO, THIS DRAWING, BY ANY THIRD PARTY, INCLUDING CONTRACTORS, SUPPLIERS, CONSULTANTS AND STAKEHOLDERS, OR THEIR EMPLOYEES OR AGENTS, WITHOUT McELHANNEY'S PRIOR WRITTEN CONSENT.
INFORMATION ON EXISTING UNDERGROUND FACILITIES MAY NOT BE COMPLETE OR ACCURATE. McELHANNEY, ITS EMPLOYEES AND DIRECTORS ARE NOT RESPONSIBLE NOR LIABLE FOR THE LOCATION OF ANY UNDERGROUND CONDUITS, PIPES, CABLES OR OTHER FACILITIES WHETHER SHOWN OR OMITTED FROM THIS PLAN. PRIOR TO CONSTRUCTION CONTRACTOR SHALL EXPOSE LOCATIONS OF ALL EXISTING FACILITIES BY HAND DIGGING OR HYDROVAC AND ADVISE THE ENGINEER OF POTENTIAL CONFLICTS.