Site Servicing and Access Conceptual Design - Drawing C101
Engineering drawing showing the proposed site servicing and access plan for 221 Atkins Road.
SITE SERVICING AND ACCESS CONCEPTUAL DESIGN
Client/Project: DAVID McALLISTER Project: CIVIL SUPPORT SERVICES, 221 ATKINS ROAD, VIEW ROYAL BC Project No.: 111720086 Drawing No.: C101 Revision: - Scale: 1:200
GENERAL NOTES:
- ALL CONSTRUCTION AND MATERIALS TO BE IN ACCORDANCE WITH THESE DRAWINGS AND APPLICABLE MMCD AND TOWN OF VIEW ROYAL STANDARD SPECIFICATIONS AND DRAWINGS.
- PERMIT TO CONSTRUCT WORKS ON MUNICIPAL ROAD ALLOWANCE AND/OR MUNICIPAL RIGHT-OF-WAY MUST BE OBTAINED FROM THE TOWN OF VIEW ROYAL ENGINEERING DEPARTMENT BEFORE WORKS COMMENCE.
- A PERMIT TO CONSTRUCT WORKS UNDER OR ADJACENT TO BOULEVARD OR BY-LAW PROTECTED TREES MUST BE OBTAINED FROM TOWN OF VIEW ROYAL PARKS DEPARTMENT BEFORE WORKS COMMENCE.
- EXISTING SERVICES MUST BE EXPOSED AT CROSSING POINTS BEFORE CONSTRUCTION.
- MAINTAIN VEHICULAR ACCESS TO EXISTING HOUSES IN AREA.
- ALL CONNECTIONS/SERVICES PROVIDED BY MUNICIPAL CREWS WILL BE COMPLETED AT THE APPLICANT'S EXPENSE FOR THE ESTIMATE AMOUNT OR THE APPLICABLE FIXED FEE.
- ALL NEW BC HYDRO, TELUS, SHAW CABLE AND FORTISBC WORKS TO BE UNDERGROUND, AND TO BE INSTALLED BY RESPECTIVE UTILITY COMPANY.
- WATER SERVICE CONNECTIONS TO EXISTING WATER MAIN TO BE MADE BY CRD WATER DEPARTMENT.
- THE CONTRACTOR SHALL REQUEST INSPECTIONS A MINIMUM 24 HOURS PRIOR TO BEING REQUIRED AND ONLY AFTER THEY HAVE SATISFIED THEMSELVES THAT NO DEFICIENCIES EXIST. REINSPECTIONS SHALL BE AT THE CONTRACTOR'S EXPENSE.
- CAUTION: CONTACT BC 1 CALL AT 1-800-474-6886 AT LEAST 48 HOURS IN ADVANCE OF EXCAVATIONS FOR LOCATION OF GAS MAINS AND SERVICES.
- ALL FILL UNDER ROADWAYS & TRAVEL AREAS TO BE COMPACTED TO MINIMUM 95% MODIFIED PROCTOR DENSITY UNLESS NOTED OTHERWISE. PROVIDE COPIES OF TEST RESULTS TO CIVIL ENGINEER FOR REVIEW.
- REFER TO ARBORIST DRAWINGS FOR TREE REMOVAL AND PROTECTION DETAILS.
- REFER TO ENVIRONMENTAL REPORT FOR STREAM PROTECTION DETAILS.
- DRIVEWAYS TO BE PAVED WITH MINIMUM 50mm OF ASPHALT.
CONSTRUCTION NOTES:
- INSTALL WATER METER AND 19mm SERVICE
- 50mm CORPORATION STOP IN IRRIGATION STYLE ACCESS BOX.
- REMOVE ROADSIDE BARRIERS AS REQUIRED FOR DRIVEWAY ACCESS.
- BUILDING TO REMAIN.
- BUILDING TO BE REMOVED.
- TREE TO BE REMOVED AT SITE SERVICING PHASE
REVISION HISTORY
| Revision | By | Appd. | YY.MM.DD |
|---|---|---|---|
| REISSUED FOR APPROVAL | KP | AG | 22.01.11 |
| FOR APPROVAL | KP | AG | 20.12.21 |
| Issued | YY.MM.DD |
PROJECT CONTACT INFORMATION
Stantec Consulting Ltd. 400 - 655 Tyee Road Victoria BC www.stantec.com 250.388.9161
Copyright Reserved The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing - any errors or omissions shall be reported to Stantec without delay. The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
SITE DETAILS AND LABELS
- LOT 1: AREA: 0.249 ha (PLAN 21115)
- LOT 2: AREA: 0.101 ha
- LOT 3: PLAN 31824
- LOT D: PLAN 21116
- NO. 221: OPEN FOUNDATION
- STREAMSIDE PROTECTION AND ENHANCEMENT AREA (SPEA) BOUNDARY
- GEOTECHNICAL SETBACK LINE
- ZONING SETBACK (7.50m)
- ARBORIST LIMIT OF DISTURBANCE LINE
- PRESENT NATURAL BOUNDARY
- CENTRELINE OF MILLSTREAM
- ATKINS ROAD
- MYRA PLACE
- EX SANITARY PUMP STATION
Utility Labels:
- CAUTION: LARGE DIAMETER WATER MAIN
- CAUTION: GAS MAIN CROSSINGS
- CAUTION: GAS MAIN
- W 1067 ST
- W 150 PVC
- G 114 DP/PE
- G 323.9 IP
- S 100
- S 50 PE
- CAP AND ABANDON EXISTING WATER SERVICE
- FLUSHOUT
- CONNECT TO EXISTING 100mm STUB WITH 100 - 50mm REDUCER
CALL BEFORE YOU DIG BC 1 CALL 1-800-474-6886
PRELIMINARY NOT TO BE USED FOR CONSTRUCTION