Committee of the Whole/Documents/Attachment 7: Site Servicing and Access Conceptual Design
Other

Attachment 7: Site Servicing and Access Conceptual Design

February 8, 2022Page 4464 sections

Final conceptual drawing for site servicing and access as part of the development permit package.

9.2.3.a Draft Community Climate Action Strategy
Drawing C101Date: January 11, 2022

CIVIL SUPPORT SERVICES

221 ATKINS ROAD, VIEW ROYAL BC

SITE SERVICING AND ACCESS CONCEPTUAL DESIGN

Client/Project: DAVID McALLISTER

Page 446

GENERAL NOTES:

  1. ALL CONSTRUCTION AND MATERIALS TO BE IN ACCORDANCE WITH THESE DRAWINGS AND APPLICABLE MMCD AND TOWN OF VIEW ROYAL STANDARD SPECIFICATIONS AND DRAWINGS.
  2. PERMIT TO CONSTRUCT WORKS ON MUNICIPAL ROAD ALLOWANCE AND/OR MUNICIPAL RIGHT-OF-WAY MUST BE OBTAINED FROM THE TOWN OF VIEW ROYAL ENGINEERING DEPARTMENT BEFORE WORKS COMMENCE.
  3. A PERMIT TO CONSTRUCT WORKS UNDER OR ADJACENT TO BOULEVARD OR BY-LAW PROTECTED TREES MUST BE OBTAINED FROM TOWN OF VIEW ROYAL PARKS DEPARTMENT BEFORE WORKS COMMENCE.
  4. EXISTING SERVICES MUST BE EXPOSED AT CROSSING POINTS BEFORE CONSTRUCTION.
  5. MAINTAIN VEHICULAR ACCESS TO EXISTING HOUSES IN AREA.
  6. ALL CONNECTION SERVICES PROVIDED BY MUNICIPAL CREWS WILL BE COMPLETED AT THE APPLICANTS EXPENSE FOR THE ESTIMATE AMOUNT OR THE APPLICABLE FIXED FEE.
  7. ALL NEW BC HYDRO, TELUS, SHAW CABLE AND FORTISBC WORKS TO BE UNDERGROUND, AND TO BE INSTALLED BY RESPECTIVE UTILITY COMPANY.
  8. WATER SERVICE CONNECTIONS TO EXISTING WATER MAIN TO BE MADE BY CRD WATER DEPARTMENT.
  9. THE CONTRACTOR SHALL REQUEST INSPECTIONS A MINIMUM 24 HOURS PRIOR TO BEING REQUIRED AND ONLY AFTER THEY HAVE SATISFIED THEMSELVES THAT NO DEFICIENCIES EXIST. REINSPECTIONS SHALL BE AT THE CONTRACTOR'S EXPENSE.
  10. CAUTION: CONTACT BC 1 CALL AT 1-800-474-6886 AT LEAST 48 HOURS IN ADVANCE OF EXCAVATIONS FOR LOCATION OF GAS MAINS AND SERVICES.
  11. ALL FILL UNDER ROADWAYS & TRAVEL AREAS TO BE COMPACTED TO MINIMUM 95% MODIFIED PROCTOR DENSITY UNLESS NOTED OTHERWISE. PROVIDE COPIES OF TEST RESULTS TO CIVIL ENGINEER FOR REVIEW.
  12. REFER TO ARBORIST DRAWINGS FOR TREE REMOVAL AND PROTECTION DETAILS.
  13. REFER TO ENVIRONMENTAL REPORT FOR STREAM PROTECTION DETAILS.
  14. DRIVEWAYS TO BE PAVED WITH MINIMUM 50mm OF ASPHALT.
Page 446

CONSTRUCTION NOTES:

  1. INSTALL WATER METER AND 19mm SERVICE.
  2. 50mm CORPORATION STOP IN IRRIGATION STYLE ACCESS BOX.
  3. REMOVE ROADSIDE BARRIERS AS REQUIRED FOR DRIVEWAY ACCESS.
  4. BUILDING TO REMAIN.
  5. BUILDING TO BE REMOVED.
  6. TREE TO BE REMOVED AT SITE SERVICING PHASE

Legend

Notes

(No text provided in this section)

Page 446

REVISION TABLE

Revision Description By Appd. YY.MM.DD
REISSUED FOR APPROVAL KP AG 22.01.11
FOR APPROVAL KP AG 20.12.21
Issued

PRELIMINARY NOT TO BE USED FOR CONSTRUCTION

Project No.: 111720086 Scale: 1:250 Drawing No.: C101

Page 446