Appendix
Attachment 12: DP2.4 - North Building Roof Plan
March 7, 2017Page 421 section
Technical plan of the building roof, including elevator overruns and mechanical equipment locations.
Eagle Creek Village Phase 2 - North Bldg
Town of View Royal, British Columbia
North Building Roof Plan
Project Details
- Consultant: OMICRON
- Address: Fifth Floor, Canadian Centre, 800 - 6th Avenue SW, Calgary, AB, T2P 3T3 CANADA
- Phone (Free): 1.877.632.3350
- Phone: 403 262 9733
- Fax: 403 262 9735
- Website: www.omicroncanada.com
- Project Number: 11 14 032
- Drawn: RI
- Checked: IM
- Date: February 1, 2017
- Drawing Number: DP2.4
- Status: NOT FOR CONSTRUCTION
Revision Schedule
| No. | Date | Remarks |
|---|---|---|
| 1 | NOV. 16, 2016 | ISSUED FOR DP |
| 2 | JAN. 25, 2017 | COMMITTEE OF WHOLE REVISIONS |
Keynote Legend
- MECHANICAL ROOF TOP UNIT
- ELEVATOR OVERRUN
- ROOF ACCESS HATCH
- ROOF DRAIN
- SCREENING FOR MECHANICAL ROOF TOP UNIT: METAL POST SUPPORTS W/ METAL FENCING, CEDAR SLAT CLADDING. SEE SCREENING ELEVATION ON DWG DP 3.1
- SCUPPER ONTO SPLASH PAD
- SBS WALKWAY MEMBRANE
Drawing Notes
- 1 ROOF PLAN: DP2.4 Scale: 1:100
- Roof Materials/Details Noted on Plan:
- 2 PLY SBS MEMBRANE
- 1:2.0% SLOPE
- ROOF BELOW @ MAIN FLOOR
- LADDER FROM ROOF ABOVE
Legal Disclaimer
OMICRON ARCHITECTURE ENGINEERING LTD. This drawing is a copyright of Omicron and shall not be used in whole or in part for any other project or by any other person or company without written permission. Dimensions shall be verified at the site and the consultant shall be notified of any discrepancy before commencing work. Do not scale this drawing. The Contractor shall ensure that all relevant facets of the drawing are read in conjunction with reference to the base floor, and other related drawings.
Page 42
Extracted from: 2017 03 07 Council Agenda - Agenda - Pdf