This site is in beta — data may be incomplete and features are still being added.
Council Meeting/Documents/Attachment 17: DP3.3 - Grade & Building Height Calculation
Appendix

Attachment 17: DP3.3 - Grade & Building Height Calculation

March 7, 2017Page 471 section

Technical calculation of the building height based on average grade.

1. CALL TO ORDER
Proposed Building Height: 46.95m (geodetic)Variance request: 1.96m

Eagle Creek Village Phase 2 - North Bldg

Town of View Royal, British Columbia
Project Number: 11 14 032

Issued For

# Date Remarks
1 NOV. 10, 2016 ISSUED FOR DP
2 JAN. 23, 2017 COMMITTEE OF WHOLE REVISIONS

Grade & Building Height Calculation

Point Existing Grade Proposed Lower of Existing or Proposed
A 23.25 23.25 23.25
B 24.35 24.35 24.35
C 24.35 24.35 24.35
D 22.14 22.14 22.14
E 25.80 25.80 25.80
F 26.30 27.00 26.30
G 27.00 27.00 27.00
H 28.20 27.00 27.00
I 28.90 27.00 27.00
J 28.70 27.00 27.00
K 28.30 27.00 27.00
Perimeter Distance (z) wAB=(A+B)/2*z
A to B 41.95 997.93 wAB
B to C 2.29 55.76 wBC
C to D 39.27 912.83 wCD
D to E 18.19 436.01 wDE
E to F 12.12 315.73 wEF
F to G 5.61 149.51 wFG
G to H 15.25 412.02 wGH
H to I 26.69 720.63 wHI
I to J 5.62 151.74 wIJ
J to K 9.13 247.88 wJK
K to A 18.13 457.02 wKA
Total 194.35 4857.05
Calculation Summary (m)
GRADE ((wAB+wBC...)/Perimeter) 24.99
Max roof height (20m FROM GRADE) 44.99
Proposed Building Height 46.95
Variance request: 1.96

OMICRON ARCHITECTURE ENGINEERING LTD.

Page 47
Extracted from: 2017 03 07 Council Agenda - Agenda - Pdf