Appendix
Attachment 4: Site Plan - ProKAD Project Management and Design
September 17, 2019Page 201 section
A detailed technical site plan showing the proposed dwelling, setbacks, and heat pump location.
Project: Proposed Residence 29 Brigadoon PlaceDate: April 30, 2018
SITE PLAN
AVERAGE GRADE CALCULATION
- POINT A = 4.6
- POINT B = 3.7
- POINT C = 3.1
- POINT D = 2.8
- POINT E = 3.7
- POINT F = 3.8
- POINT G = 3.6
- POINT H = 3.8
- POINT I = 3.8
- POINT J = 4.6
Calculations:
- A TO B: (4.6 + 3.7) / 2 x 7.02 = 29.13
- B TO C: (3.1 + 3.7) / 2 x 8.73 = 29.23
- C TO D: (3.1 + 2.8) / 2 x 13.30 = 39.23
- D TO E: (2.8 + 3.7) / 2 x 19.23 = 62.50
- E TO F: (2.7 + 3.8) / 2 x 4.31 = 13.71
- F TO G: (3.6 + 3.8) / 2 x 1.14 = 4.18
- G TO H: (3.6 + 3.8) / 2 x 3.97 = 14.65
- H TO I: (3.8 + 3.8) / 2 x 11.21 = 41.48
- I TO J: (3.8 + 4.6) / 2 x 8.05 = 33.17
239.11 / 61.64 = 3.87
SITE PLAN ANNOTATIONS
- PROPOSED HEAT PUMP LOCATION (Clouded handwritten note with arrow pointing to the side yard)
- PERMITTED / (REQUIRE) HEAT PUMP LOCATION (Handwritten note in blue with arrow pointing to a hatched area within the development permit area)
- DEVELOPMENT PERMIT AREA BOUNDARY (Indicated by a pink outline)
- BUILDING (Note: INTERIOR HEAT PUMP UNIT)
- FRONT YARD (Area highlighted in blue)
- SIDE YARD (Areas highlighted in yellow)
- REAR YARD
- PORTAGE INLET
- PRESENT NATURAL BOUNDARY AND NATURAL BOUNDARY PER PLAN 11919
- EXISTING DWELLING + ACCESSORY STRUCTURES TO BE DEMOLISHED
- GRADUAL ROCK LANDSCAPING REQ'D IN THIS AREA TO DEAL W/ GRADE
- LINE REPRESENTS CONDUIT FOR FUTURE UNDERGROUND ELECTRICAL SERVICE
- LINE REPRESENTS CONDUIT FOR FUTURE TELEPHONE SERVICE
PROJECT INFORMATION
CIVIC ADDRESS: 25 BRIGADOON PLACE, VIEW ROYAL, BC
LEGAL DESCRIPTION: LOT 6, SECTION 2 ESQUIMALT DISTRICT, PLAN 11919
SURVEY PREPARED BY: WEY MAYENBURG LAND SURVEYING INC. #4 - 2227 JAMES WHITE BOULEVARD SIDNEY, BC V8L 1Z5 TELEPHONE 250 656 5155 FILE 160303: SIT-GH
REVISION HISTORY
| DATE | DESCRIPTION |
|---|---|
| 15/05/23 | DEVELOPMENT VARIANCE PERMIT |
| 16/11/10 | CONSTRUCTION |
| 16/11/24 | ENGINEERING COMMENTS |
| 16/12/30 | FDP / PRICING |
| 18/01/21 | CLIENT REVIEW |
| ISSUED | REVISED DRAWN KAD |
DRAWING DETAILS
- PROJECT TITLE: PROPOSED RESIDENCE, 25 BRIGADOON PLACE, VIEW ROYAL, BC
- DRAWING TITLE: SITE PLAN
- PROJECT NO: 2017-010
- DWG NO: A2
- SCALE: AS NOTED
Page 20